Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 144: 107993, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34823072

RESUMO

Biotin is widely used in infant formula to prevent biotin deficiency of newborn babies and in beauty products as nutritional supplements for coenzymatic functions and having strong nails, shiny hair, and skin over the last few years. There is a need for the development of a fast, simple and reusable assay method to perform biotin determination at very low concentrations. Biotin determination has achieved with a prepared potentiometric biotin sensor that has a very wide concentration range (10-15M-10-7M) and a lower detection limit (0.3 10-15M) with a very good regression coefficient (0.9925). A quick response (7 min), good accuracy (recovery 100.4-103.7%), reproducible, reusable (10 times), and long-term stability (3 months) have been obtained using the prepared potentiometric sensor. The obtained results have proved that the prepared potentiometric sensor can be used for biotin determination in real samples.


Assuntos
Estreptavidina
2.
Waste Manag ; 34(1): 162-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24112854

RESUMO

The objective of this study was to predict the number of refrigerators containing CFC-11 blown isolation foam and the amount of CFC-11 banked in these refrigerators. By using a Weibull-based survival function, the number of CFC-11 containing and still-functioning refrigerators was estimated to be approximately 1.6 million in 2013 in Turkey. In order to determine the amount of CFC-11 in the isolation foam of these refrigerators, polyurethane (PU) foam samples were taken from a refrigerator manufactured in 1993 and the quantity of CFC-11 was analyzed by a GC-MS. It was determined that 113-195 mg CFC-11/g PU remains in the PU foam depending on the location such as door, sides, top and bottom. Knowing that a mid-sized refrigerator contains 4 kg PU on average, the total amount of PU foam to be disposed of is 6344 tons when the CFC-11 containing refrigerators in Turkey become obsolete in the near future. Furthermore, 717-1237 tons of CFC-11 are expected to be banked in the PU foam of these refrigerators which will exert an equivalent amount of ozone depleting potential (ODP). In addition, the global warming potential will vary between 3.4 and 5.9 million tons of CO2.


Assuntos
Poluentes Atmosféricos/análise , Clorofluorcarbonetos de Metano/análise , Refrigeração/instrumentação , Eliminação de Resíduos/métodos , Aquecimento Global , Poliuretanos , Turquia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...