Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Cytol ; : 1-9, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648759

RESUMO

INTRODUCTION: Digitizing cytology slides presents challenges because of their three-dimensional features and uneven cell distribution. While multi-Z-plane scan is a prevalent solution, its adoption in clinical digital cytopathology is hindered by prolonged scanning times, increased image file sizes, and the requirement for cytopathologists to review multiple Z-plane images. METHODS: This study presents heuristic scan as a novel solution, using an artificial intelligence (AI)-based approach specifically designed for cytology slide scanning as an alternative to the multi-Z-plane scan. Both the 21 Z-plane scan and the heuristic scan simulation methods were used on 52 urine cytology slides from three distinct cytopreparations (Cytospin, ThinPrep, and BD CytoRich™ [SurePath]), generating whole-slide images (WSIs) via the Leica Aperio AT2 digital scanner. The AI algorithm inferred the WSI from 21 Z-planes to quantitate the total number of suspicious for high-grade urothelial carcinoma or more severe cells (SHGUC+) cells. The heuristic scan simulation calculated the total number of SHGUC+ cells from the 21 Z-plane scan data. Performance metrics including SHGUC+ cell coverage rates (calculated by dividing the number of SHGUC+ cells identified in multiple Z-planes or heuristic scan simulation by the total SHGUC+ cells in the 21 Z-planes for each WSI), scanning time, and file size were analyzed to compare the performance of each scanning method. The heuristic scan's metrics were linearly estimated from the 21 Z-plane scan data. Additionally, AI-aided interpretations of WSIs with scant SHGUC+ cells followed The Paris System guidelines and were compared with original diagnoses. RESULTS: The heuristic scan achieved median SHGUC+ cell coverage rates similar to 5 Z-plane scans across three cytopreparations (0.78-0.91 vs. 0.75-0.88, p = 0.451-0.578). Notably, it substantially reduced both scanning time (137.2-635.0 s vs. 332.6-1,278.8 s, p < 0.05) and image file size (0.51-2.10 GB vs. 1.16-3.10 GB, p < 0.05). Importantly, the heuristic scan yielded higher rates of accurate AI-aided interpretations compared to the single Z-plane scan (62.5% vs. 37.5%). CONCLUSION: We demonstrated that the heuristic scan offers a cost-effective alternative to the conventional multi-Z-plane scan in digital cytopathology. It achieves comparable SHGUC+ cell capture rates while reducing both scanning time and image file size, promising to aid digital urine cytology interpretations with a higher accuracy rate compared to the conventional single (optimal) plane scan. Further studies are needed to assess the integration of this new technology into compatible digital scanners for practical cytology slide scanning.

2.
J Pathol Inform ; 15: 100346, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38125926

RESUMO

Background: Acquiring well-focused digital images of cytology slides with scanners can be challenging due to the 3-dimensional nature of the slides. This study evaluates performances of whole-slide images (WSIs) obtained from 2 different cytopreparations by 2 distinct scanners with 3 focus modes. Methods: Fourteen urine specimens were collected from patients with urothelial carcinoma. Each specimen was equally divided into 2 portions, prepared with Cytospin and ThinPrep methods and scanned for WSIs using Leica (Aperio AT2) and Hamamatsu (NanoZoomer S360) scanners, respectively. The scan settings included 3 focus modes (default, semi-auto, and manual) for single-layer scanning, along with a manual focus mode for 21 Z-layers scanning. Performance metrics were evaluated including scanning success rate, artificial intelligence (AI) algorithm-inferred atypical cell numbers and coverage rate (atypical cell numbers in single or multiple Z-layers divided by the total atypical cell numbers in 21 Z-layers), scanning time, and image file size. Results: The default mode had scanning success rates of 85.7% or 92.9%, depending on the scanner used. The semi-auto mode increased success to 92.9% or 100%, and manual even further to 100%. However, these changes did not affect the standardized median atypical cell numbers and coverage rates. The selection of scanners, cytopreparations, and Z-stacking influenced standardized median atypical cell numbers and coverage rates, scanning times, and image file sizes. Discussion: Both scanners showed satisfactory scanning. We recommend using semi-auto or manual focus modes to achieve a scanning success rate of up to 100%. Additionally, a minimum of 9-layer Z-stacking at 1 µm intervals is required to cover 80% of atypical cells. These advanced focus methods do not impact the number of atypical cells or their coverage rate. While Z-stacking enhances the AI algorithm's inferred quantity and coverage rates of atypical cells, it simultaneously results in longer scanning times and larger image file sizes.

3.
Cancer Cytopathol ; 130(11): 872-880, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35727052

RESUMO

BACKGROUND: The Paris System for Reporting Urinary Cytology (TPS) has been shown to improve bladder cancer diagnosis. Advances in artificial intelligence (AI) may assist and improve the clinical workflow by applying TPS in routine diagnostic services. METHODS: A deep-learning-based algorithm was developed to identify urothelial cancer candidate cells using whole-slide images (WSIs). In the testing cohort, 131 urine cytology slides were retrospectively retrieved and analyzed using this AI algorithm. The authors compared the performance of one cytopathologist and two cytotechnologists using AI-assisted digital urine cytology. Then, the AI-assisted WSIs were evaluated in the clinical workflow. The cytopathologist first made a diagnosis by reviewing the AI-inferred WSIs and quantitative data (nuclear-to-cytoplasmic ratio and nuclear size) for each sample. After a washout period, the same cytopathologist made a diagnosis for the same samples using direct microscopy. All diagnosis results were compared with the expert panel consensus. RESULTS: The AI-assisted diagnosis by the two cytotechnologists and the one cytopathologist demonstrated performance results that were comparable to the expert panel consensus (sensitivity, 79.5% and 82.1% vs. 92.3%, respectively; specificity, 100% and 98.9% vs. 100%, respectively). Furthermore, the performance of the AI-assisted WSIs compared with the microscopic diagnosis by the cytopathologist demonstrated superior sensitivity (92.3% vs. 87.2%) and negative predictive value (96.8% vs. 94.8%). In addition, the AI-assisted reporting demonstrated near perfect agreement with the expert panel consensus (κ = 0.944) and the microscopic diagnosis (κ = 0.862). CONCLUSIONS: The AI algorithm developed by the authors effectively assisted TPS-based reporting by providing AI-inferred WSIs and quantitative data.


Assuntos
Inteligência Artificial , Neoplasias Urológicas , Humanos , Projetos Piloto , Estudos Retrospectivos , Citodiagnóstico/métodos , Algoritmos , Neoplasias Urológicas/diagnóstico , Urina , Urotélio/patologia
4.
PLoS One ; 15(9): e0236964, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32931498

RESUMO

BACKGROUND: Short bowel syndrome (SBS) results from significant loss of small intestinal length. In response to this loss, adaptation occurs, with Epidermal Growth Factor Receptor (EGFR) being a key driver. Besides enhanced enterocyte proliferation, we have revealed that adaptation is associated with angiogenesis. Further, we have found that small bowel resection (SBR) is associated with diminished oxygen delivery and elevated levels of hypoxia-inducible factor 1-alpha (HIF1α). METHODS: We ablated EGFR in the epithelium and endothelium as well as HIF1α in the epithelium, ostensibly the most hypoxic element. Using these mice, we determined the effects of these genetic manipulations on intestinal blood flow after SBR using photoacoustic microscopy (PAM), intestinal adaptation and angiogenic responses. Then, given that endothelial cells require a stromal support cell for efficient vascularization, we ablated EGFR expression in intestinal subepithelial myofibroblasts (ISEMFs) to determine its effects on angiogenesis in a microfluidic model of human small intestine. RESULTS: Despite immediate increased demand in oxygen extraction fraction measured by PAM in all mouse lines, were no differences in enterocyte and endothelial cell EGFR knockouts or enterocyte HIF1α knockouts by POD3. Submucosal capillary density was also unchanged by POD7 in all mouse lines. Additionally, EGFR silencing in ISEMFs did not impact vascular network development in a microfluidic device of human small intestine. CONCLUSIONS: Overall, despite the importance of EGFR in facilitating intestinal adaptation after SBR, it had no impact on angiogenesis in three cell types-enterocytes, endothelial cells, and ISEMFs. Epithelial ablation of HIF1α also had no impact on angiogenesis in the setting of SBS.


Assuntos
Subunidade alfa do Fator 1 Induzível por Hipóxia/fisiologia , Intestino Delgado/irrigação sanguínea , Neovascularização Fisiológica , Síndrome do Intestino Curto/cirurgia , Animais , Receptores ErbB/genética , Receptores ErbB/fisiologia , Feminino , Células Endoteliais da Veia Umbilical Humana , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Intestino Delgado/metabolismo , Masculino , Camundongos , Técnicas Analíticas Microfluídicas , Miofibroblastos , Síndrome do Intestino Curto/metabolismo
5.
J Biomed Opt ; 22(4): 41017, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28241305

RESUMO

We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.


Assuntos
Técnicas Fotoacústicas , Tomografia Computadorizada por Raios X/métodos , Animais , Tomografia Computadorizada por Raios X/instrumentação
6.
Cancer Biol Ther ; 18(2): 101-105, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28045569

RESUMO

Using photoacoustic microscopy (PAM), we evaluated non-invasively oxygenation and vascularization in vivo due to multiple myeloma (MM) progression. Mice injected with MM.1S-GFP were monitored with a fluorescence microscope for tumor progression. In vivo PAM of the cerebral bone marrow quantified the total oxygen saturation (sO2). At 28 days after the MM cell injection, the total sO2 had decreased by half in the developing tumor regions, while in the non-tumor regions it had decreased by 20% compared with the value at one day post MM injection. The blood vessel density was reduced by 35% in the developing tumor regions, while in the non-tumor regions it was reduced by 8% compared with the value at one day post MM injection. Hence, PAM corroborated the development of hypoxia due to MM progression and demonstrated decreased vascularization surrounding the tumor areas.


Assuntos
Microscopia de Fluorescência/métodos , Mieloma Múltiplo/diagnóstico , Técnicas Fotoacústicas/métodos , Animais , Hipóxia Celular , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos SCID , Mieloma Múltiplo/patologia , Ensaios Antitumorais Modelo de Xenoenxerto
7.
J Biomed Opt ; 21(2): 20501, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26882446

RESUMO

Angiogenesis in a tumor region creates arteriovenous (AV) shunts that cause an abnormal venous blood oxygen saturation ( sO2 ) distribution. Here, we applied optical-resolution photoacoustic microscopy to study the AV shunting in vivo. First, we built a phantom to image sO2 distribution in a vessel containing converged flows from two upstream blood vessels with different sO2 values. The phantom experiment showed that the blood from the two upstream vessels maintained a clear sO2 boundary for hundreds of seconds, which is consistent with our theoretical analysis using a diffusion model. Next, we xenotransplanted O-786 tumor cells in mouse ears and observed abnormal sO2 distribution in the downstream vein from the AV shunts in vivo. Finally, we identified the tumor location by tracing the sO2 distribution. Our study suggests that abnormal sO2 distribution induced by the AV shunts in the vessel network may be used as a new functional benchmark for early tumor detection.


Assuntos
Microscopia/métodos , Neovascularização Patológica/fisiopatologia , Oximetria/métodos , Oxigênio/sangue , Técnicas Fotoacústicas/métodos , Animais , Difusão , Orelha/irrigação sanguínea , Desenho de Equipamento , Camundongos , Neoplasias , Imagens de Fantasmas
8.
Biomed Opt Express ; 6(3): 918-32, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25798315

RESUMO

Optical-resolution photoacoustic microscopy (OR-PAM) has become a major experimental tool of photoacoustic tomography, with unique imaging capabilities for various biological applications. However, conventional imaging systems are all table-top embodiments, which preclude their use in internal organs. In this study, by applying the OR-PAM concept to our recently developed endoscopic technique, called photoacoustic endoscopy (PAE), we created an optical-resolution photoacoustic endomicroscopy (OR-PAEM) system, which enables internal organ imaging with a much finer resolution than conventional acoustic-resolution PAE systems. OR-PAEM has potential preclinical and clinical applications using either endogenous or exogenous contrast agents.

9.
J Biophotonics ; 8(4): 303-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25077689

RESUMO

We have enhanced photoacoustic microscopy with three-dimensional arbitrary trajectory (3-DAT) scanning, which can rapidly image selected vessels over a large field of view (FOV) and maintain a high signal-to-noise ratio (SNR) despite the depth variation of the vessels. We showed that hemoglobin oxygen saturation (sO2 ) and blood flow can be measured simultaneously in a mouse ear in vivo at a frame rate 67 times greater than that of a traditional two-dimensional raster scan. We also observed sO2 dynamics in response to switching from systemic hypoxia to hyperoxia. 3-DAT-scanning photoacoustic microscopy. Schematic diagram of the 3D scanning stage and method.


Assuntos
Imageamento Tridimensional/métodos , Microscopia/métodos , Técnicas Fotoacústicas/métodos , Animais , Orelha/irrigação sanguínea , Cabelo , Hemoglobinas/metabolismo , Humanos , Imageamento Tridimensional/instrumentação , Camundongos , Microscopia/instrumentação , Oxigênio/metabolismo , Técnicas Fotoacústicas/instrumentação
10.
J Biomed Opt ; 19(9): 96011, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25223708

RESUMO

Accurate quantification of microvasculature remains of interest in fundamental pathophysiological studies and clinical trials. Current photoacoustic microscopy can noninvasively quantify properties of the microvasculature, including vessel density and diameter, with a high spatial resolution. However, the depth range of focus (i.e., focal zone) of optical-resolution photoacoustic microscopy (OR-PAM) is often insufficient to encompass the depth variations of features of interest­such as blood vessels­due to uneven tissue surfaces. Thus, time-consuming image acquisitions at multiple different focal planes are required to maintain the region of interest in the focal zone. We have developed continuous three-dimensional motorized contour-scanning OR-PAM, which enables real-time adjustment of the focal plane to track the vessels' profile. We have experimentally demonstrated that contour scanning improves the signal-to-noise ratio of conventional OR-PAM by as much as 41% and shortens the image acquisition time by 3.2 times. Moreover, contour-scanning OR-PAM more accurately quantifies vessel density and diameter, and has been applied to studying tumors with uneven surfaces.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia/métodos , Microvasos/anatomia & histologia , Técnicas Fotoacústicas/métodos , Animais , Orelha/irrigação sanguínea , Melanoma Experimental/irrigação sanguínea , Camundongos , Razão Sinal-Ruído , Neoplasias Cutâneas/irrigação sanguínea
11.
Opt Lett ; 39(13): 3814-7, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24978744

RESUMO

We present an optically encoded photoacoustic (PA) flow imaging method based on optical-resolution PA microscopy. An intensity-modulated continuous-wave laser photothermally encodes the flowing medium, and a pulsed laser generates PA waves to image the encoded heat pattern. Flow speeds can be calculated by cross correlation. The method was validated in phantoms at flow speeds ranging from 0.23 to 11 mm/s. Venous blood flow speed in a mouse ear was also measured.


Assuntos
Microscopia Acústica/métodos , Técnicas Fotoacústicas/métodos , Reologia/métodos , Animais , Velocidade do Fluxo Sanguíneo , Orelha/irrigação sanguínea , Desenho de Equipamento , Hemorreologia , Camundongos , Camundongos Nus , Microscopia Acústica/instrumentação , Microscopia Acústica/estatística & dados numéricos , Fenômenos Ópticos , Imagens de Fantasmas , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/estatística & dados numéricos , Reologia/instrumentação , Reologia/estatística & dados numéricos
12.
Opt Lett ; 39(7): 2117-20, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24686689

RESUMO

We have developed fully motorized optical-resolution photoacoustic microscopy (OR-PAM), which integrates five complementary scanning modes and simultaneously provides a high imaging speed and a wide field of view (FOV) with 2.6 µm lateral resolution. With one-dimensional (1D) motion-mode mechanical scanning, we measured the blood flow through a cross section of a blood vessel in vivo. With two-dimensional (2D) optical scanning at a laser repetition rate of 40 kHz, we achieved a 2 kHz B-scan rate over a range of 50 µm with 20 A-lines and 50 Hz volumetric-scan rate over a FOV of 50 µm × 50 µm with 400 A-lines, which enabled real-time tracking of cellular dynamics in vivo. With synchronized 1D optical and 2D mechanical hybrid scanning, we imaged a 10 mm × 8 mm FOV within three minutes, which is 20 times faster than the conventional mechanical scan in our second-generation OR-PAM. With three-dimensional mechanical contour scanning, we maintained the optimal signal-to-noise ratio and spatial resolution of OR-PAM while imaging objects with uneven surfaces, which is essential for quantitative studies.


Assuntos
Microscopia/instrumentação , Fenômenos Ópticos , Técnicas Fotoacústicas/instrumentação , Animais , Orelha/irrigação sanguínea , Desenho de Equipamento , Eritrócitos/citologia , Hemoglobinas/análise , Camundongos
13.
Opt Lett ; 39(6): 1473-1476, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24690816

RESUMO

Photoacoustic (PA) endoscopy for human urogenital imaging has the potential to diagnose many important diseases, such as endometrial and prostate cancers. We have specifically developed a 12.7 mm diameter, rigid, side-scanning PA endoscopic probe for such applications. The key features of this endoscope are the streamlined structure for smooth cavity introduction and the proximal actuation mechanism for fast scanning. Here we describe the probe's composition and scanning mechanism and present in vivo experimental results suggesting its potential for comprehensive clinical applications.


Assuntos
Endoscópios , Endossonografia/instrumentação , Aumento da Imagem/instrumentação , Técnicas Fotoacústicas/instrumentação , Sistema Urogenital/diagnóstico por imagem , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Coelhos , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Biomed Opt ; 17(7): 070504, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22894460

RESUMO

Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced fluctuations in blood flow speed were clearly observed in arteries and arterioles, but not in veins or venules. Simultaneously recorded electrocardiograms served as references to measure the travel time of the pulse wave between two cross sections of a chosen vessel and vessel segmentation analysis enabled accurate quantification of the travel distance. PWVs were quantified in ten vessel segments from two mice. Statistical analysis shows a linear correlation between the PWV and the vessel diameter which agrees with known physiology.


Assuntos
Artérias/anatomia & histologia , Artérias/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Microscopia/instrumentação , Técnicas Fotoacústicas/instrumentação , Fluxo Pulsátil/fisiologia , Análise de Onda de Pulso/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Ultrasonics ; 51(4): 472-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21211810

RESUMO

Guided waves propagating in cylindrical tubes are frequently applied for the characterization of material or geometrical properties of tubes. In a tube, guided waves can propagate in the axial direction and called axial guided waves, or in the circumferential direction called circumferential guided waves. Dispersion spectra for the axial and circumferential guided waves share some common behaviors and however exhibit some particular behaviors of their own. This study provides an investigation with theoretical modeling, experimental measurements, and a simplex-based inversion procedure to explore the similarity and difference between the axial guided waves and circumferential guided waves, aiming at providing useful information while axial and circumferential guided waves are applied in the area of material characterization. The sensitivity to the radius curvature for the circumferential guided waves dispersion spectra is a major point that makes circumferential guided waves different from axial guided waves. For the purpose of material characterization, both axial and circumferential guided waves are able to extract an elastic moduli and wall-thickness information from the dispersion spectra, however, radius information can only be extracted from the circumferential guided waves spectra.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...