Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 30(3): 408-416, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31899505

RESUMO

OBJECTIVES: Handmade trileaflet expanded polytetrafluoroethylene valved conduit developed using the flip-over method has been tailored for pulmonary valve reconstruction with satisfactory outcomes. We investigated the in vitro performance of the valve design in a mock circulatory system with various conduit sizes. In our study, the design was transformed into a transcatheter stent graft system which could fit in original valved conduits in a valve-in-valve fashion. METHODS: Five different sizes of valved polytetrafluoroethylene vascular grafts (16, 18, 20, 22 and 24 mm) were mounted onto a mock circulatory system with a prism window for direct leaflets motion observation. Transvalvular pressure gradients were recorded using pressure transducers. Mean and instant flows were determined via a rotameter and a flowmeter. Similar flip-over trileaflet valve design was then carried out in 3 available stent graft sizes (23, 26 and 28.5 mm, Gore aortic extender), which were deployed inside the valved conduits. RESULTS: Peak pressure gradient across 5 different sized graft valves, in their appropriate flow setting (2.0, 2.5 and 5.0 l/min), ranged from 4.7 to 13.2 mmHg. No significant valve regurgitation was noted (regurgitant fraction: 1.6-4.9%) in all valve sizes and combinations. Three sizes of the trileaflet-valved stent grafts were implanted in the 4 sizes of valved conduits except for the 16-mm conduit. Peak pressure gradient increase after valved-stent graft-in-valved-conduit setting was <10 mmHg in all 4 conduits. CONCLUSIONS: The study showed excellent in vitro performance of trileaflet polytetrafluoroethylene valved conduits. Its valved stent graft transformation provided data which may serve as a reference for transcatheter valve-in-valve research in the future.


Assuntos
Prótese Vascular , Próteses Valvulares Cardíacas , Politetrafluoretileno , Desenho de Prótese , Valva Pulmonar , Stents , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Teste de Materiais , Modelos Cardiovasculares
2.
J Artif Organs ; 17(2): 178-85, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24619800

RESUMO

Non-physiologic turbulent flow occurs in medical cardiovascular devices resulting in hemodynamic stresses that may damage red blood cells (RBC) and cause hemolysis. Hemolysis was previously thought to result from Reynolds shear stress (RSS) in turbulent flows. A more recent hypothesis suggests that turbulent viscous shear stresses (TVSS) at spatial scales similar in size to RBCs are related to their damage. We applied two-dimensional digital particle image velocimetry to measure the flow field of a free-submerged axisymmetric jet that was utilized to hemolyze porcine RBCs in selected locations. Assuming a dynamic equilibrium for the sub-grid scale (SGS) energy flux between the resolved and the sub-grid scales, the SGS energy flux was calculated from the strain rate tensor computed from the resolved velocity fields. The SGS stress was determined by the Smagorinsky model, from which the turbulence dissipation rate and then TVSS were estimated. Our results showed the hemolytic threshold of the Reynolds stresses was up to 517 Pa, and the TVSSs were at least an order of magnitude less than the RSS. The results provide further insight into the relationship between turbulence and RBC damage.


Assuntos
Eritrócitos/patologia , Hemólise/fisiologia , Hemorreologia/fisiologia , Fluxo Pulsátil/fisiologia , Estresse Mecânico , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Cultura de Células , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Reologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...