Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Hip & Pelvis ; : 190-199, 2021.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-914504

RESUMO

Purpose@#We analyzed the microstructure and bone mineral density (BMD) of the trabecular bone in the femoral head of patients with osteoporosis. @*Materials and Methods@#Sixteen femoral heads with osteoporotic femoral neck fractures underwent microcomputed tomography scanning. In each tip-apex distance (TAD) of 15, 20, and 25 mm, five regions of interest (ROIs) were extracted from the central, anterior, posterior, superior, and inferior sections. A total of 15 ROIs were extracted from TADs of 15, 20, and 25 mm. The measurement parameters included BMD, percent bone volume: bone volume/total volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), structural model index (SMI), and degree of anisotropy (DOA). @*Results@#The lowest BMD and BV/TV values were observed in the inferior region and differed significantly from those in other regions (P<0.05). Lower Tb.Th and Tb.N values were observed in the inferior region compared with those in the central region (P<0.05). The highest SMI value was observed in the inferior region (P<0.05). With TAD of 15 and 20 mm, the DOA values in the inferior region were lower than those in the anterior region (P<0.05). Lower BMD and BV/TV values were observed in the anterior, central, and inferior regions of TAD of 15 mm compared with those in the corresponding regions of TAD of 25 mm (P<0.05). @*Conclusion@#Positioning the lag screw between TAD of 20 to 25 mm and in the inferior region is recommended, and TAD of less than 15 mm is not recommended.

2.
Chinese Journal of Trauma ; (12): 1132-1137, 2013.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-439193

RESUMO

Objective To compare the discrepancy and consistency in mechanical axis and component position measured by electromagnetic navigation and radiograph in total knee arthroplasty (TKA)to assess whether the navigation system can be used as a substitute for radiograph.Methods A perspective study was performed on 40 cases (61 knees) undergone primary TKA under electromagnetic navigation from July 2006 to December 2006.There were 4 males and 36 females,at a mean age of (66.9 ±8.1) years (range,58-79 years).Mechanical axis angle,distal femoral and proximal tibial cut slope in coronal view (angles cα,β) were recorded both pre-and post-operatively with an intraoperative navigation system and compared against the mechanical axis angle,coronal femoral and tibial slope (angles α,β)measured via full-length radiograph of the lower limb preoperatively and at postoperative 3 months.Consistency in measurement of the same parameters with the two methods was assessed using intraclass coefficiency correlation (ICC).Results Mechanical axis determined by navigation and radiograph showed a mean valgus angle of 9.60° and 9.99° preoperatively and of 1.23° and 1.64° postoperatively,but the two pair parameters revealed no significant differences in the non-parametric test.Mean angle α determined by navigation and radiograph was 89.98° and 88.96° respectively (P < 0.05),and mean angleβ was 90.21 ° and 89.59°respectively (P < 0.05).With deviation value ≤3°,ICC for pre-and post-operative mechanical axis angles,angle α and angleβ was 0.887,0.754,0.632,0.640 respectively.Conclusions Within the acceptable range of deviation,intraoperative navigation data can reflect the pre-and post-operative mechanical axis and prosthesis position evaluated by radiograph.However,the advantages over the consistency of the two measurement methods rest with the evaluation of pre-and post-operative mechanical

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...