Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Somatosens Mot Res ; 41(1): 48-55, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36721377

RESUMO

PURPOSE AND METHOD: The purpose of this study was to determine the changes in the Blood Oxygen Level Dependent signal of Primary somatosensory area (S1) and Brodmann area 3 (BA3) per finger and phalanx in comparison to the activation voxel when 250 Hz vibratory stimulation with high sensitivity for the Pacinian corpuscle was given to the four fingers and three phalanges. RESULTS: The result of analyzing the activation voxel showed a significant difference for S1 per finger and phalanx, but for BA3, no significant difference was observed despite a similar trend to S1. In contrast, the activation intensity (BOLD) displayed a significant difference for S1 per finger and phalanx and for BA3, where the activation voxel had no significant variation. In addition, while the result of S1 did not indicate whether the index or the little fingers had the highest sensitivity based on the BOLD signal per finger, the result of BA3 marked the strongest BOLD signal for the little finger as a response to 250 Hz vibratory stimulation. The activation intensity per phalanx was the highest for the intermediate phalanx for S1 and BA3, which was in line with a previous study comparing the activation voxel. CONCLUSIONS: The method based on the intensity of the nerve activation is presumed to have high sensitivity as the signal intensity is monitored within a specific, defined area. Thus, for the extraction of brain activation patterns of micro-domains, such as BA3, monitoring the BOLD signal that reflects the nerve activation intensity more sensitively is likely to be advantageous.


Assuntos
Imageamento por Ressonância Magnética , Córtex Somatossensorial , Córtex Somatossensorial/fisiologia , Imageamento por Ressonância Magnética/métodos , Dedos/inervação , Mapeamento Encefálico/métodos
2.
Neuroreport ; 34(10): 501-505, 2023 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-37270841

RESUMO

OBJECTIVES: Binaural beats are auditory beat stimulation that produces sounds and induces a specific state of brain wave based on the difference in the frequency of stimulation. This study aimed to investigate the effects of inaudible binaural beats on visuospatial memory at 18 000 Hz reference and 10 Hz difference frequencies. METHODS: Eighteen adult subjects in their twenties were enrolled, including 12 males (mean age: 23.8 ±â€…1.2) and 6 females (mean age: 22.8 ±â€…0.8). An auditory stimulator providing 10 Hz binaural beats stimulation via 18 000 Hz to the left and 18 010 Hz to the right ears was used. The experiment consisted of two 5-min phases, including a rest phase and a task phase involving task performance without (Task-only) and with binaural beats stimulation (Task+BB). A 3-back task was used to measure visuospatial memory. Cognitive ability measured by task performance (accuracy and reaction time) with and without binaural beats, as well as variations in alpha power across different brain domains, were compared using paired t-tests. RESULTS: Compared to the Task-only condition, the Task+BB condition had significantly higher accuracy and significantly shorter reaction time. The electroencephalogram analysis showed that the reduction level in alpha power for the task performance under the Task+BB condition was significantly lower in all brain areas except the frontal, compared to that under the Task-only condition. CONCLUSION: The significance of this study lies in having verified the independent effects of binaural beats stimulation without any auditory influence, based on visuospatial memory.


Assuntos
Ondas Encefálicas , Eletroencefalografia , Adulto , Masculino , Feminino , Humanos , Adulto Jovem , Estimulação Acústica , Encéfalo/fisiologia , Tempo de Reação/fisiologia
3.
Technol Health Care ; 31(S1): 3-8, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37038776

RESUMO

BACKGROUND: Several studies have continuously investigated FFRs using binaural beat (BB) stimulations and their related effects. However, only a few studies have investigated the differences in BB stimulation effects according to basic demographic characteristics, such as gender and age. OBJECTIVE: This study aimed to determine the alpha wave activity after a 10-Hz BB stimulation and subsequently identify differences according to gender across all brain areas (frontal, central, parietal, temporal, and occipital areas). METHODS: A total of 23 healthy adults (11 male and 12 female), aged 20-29, participated in the study. For the 10-Hz BB stimulation, pure tone auditory stimuli of 250 and 260 Hz were given to the left and right ear, respectively. Through a power spectrum analysis of the phase-excluding BBs (non-BBs) and phase-including 10-Hz BBs (α-BBs), the alpha power at each brain area was estimated. These values were compared using a mixed-design ANOVA. RESULTS: With the exception of the temporal area, all other brain areas showed a significant increase in alpha power for α-BBs compared to those of non-BBs. However, the difference according to gender was not significant. CONCLUSION: The results indicated the lack of gender effects in alpha wave generation through a 10-Hz BB stimulation.


Assuntos
Eletroencefalografia , Potenciais Evocados Auditivos , Adulto , Humanos , Masculino , Feminino , Potenciais Evocados Auditivos/fisiologia , Estimulação Acústica/métodos , Eletroencefalografia/métodos , Encéfalo/fisiologia , Cabeça
4.
Medicine (Baltimore) ; 101(26): e29819, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35777013

RESUMO

This study aimed to determine the effects of the binaural beat (BB) on brainwave induction using an inaudible baseline frequency outside the audible frequency range. Experiments were conducted on 18 subjects (11 males [mean age: 25.7 ± 1.6 years] and 7 females [mean age: 24.0 ± 0.6 years]). A BB stimulation of 10 Hz was exerted by presenting frequencies of 18,000 Hz and 18,010 Hz to the left and right ears, respectively. A power spectrum analysis was performed to estimate the mean of the absolute power of the alpha frequency range (8-13 Hz). The variation in the mean alpha power during the rest and stimulation phases in each brain area was compared using the Wilcoxon signed-rank test. Compared to the rest phase, the stimulation phase with BB showed an increasing trend in the mean alpha power across all 5 brain areas. Notably, a significant increase was found in the frontal, central, and temporal areas. This is a significant study in that it determines the effects of only BB without the influence of auditory perception, which has been overlooked in previous studies.


Assuntos
Ondas Encefálicas , Estimulação Acústica , Adulto , Percepção Auditiva/fisiologia , Encéfalo/fisiologia , Ondas Encefálicas/fisiologia , Orelha , Feminino , Humanos , Masculino , Adulto Jovem
5.
Front Neurosci ; 15: 733423, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34658771

RESUMO

This study demonstrates the feasibility of a mid-air means of haptic stimulation at a long distance using the plasma effect induced by laser. We hypothesize that the stress wave generated by laser-induced plasma in the air can propagate through the air to reach the nearby human skin and evoke tactile sensation. To validate this hypothesis, we investigated somatosensory responses in the human brain to laser plasma stimuli by analyzing electroencephalography (EEG) in 14 participants. Three types of stimuli were provided to the index finger: a plasma stimulus induced from the laser, a mechanical stimulus transferred through Styrofoam stick, and a sham stimulus providing only the sound of the plasma and mechanical stimuli at the same time. The event-related desynchronization/synchronization (ERD/S) of sensorimotor rhythms (SMRs) in EEG was analyzed. Every participant verbally reported that they could feel a soft tap on the finger in response to the laser stimulus, but not to the sham stimulus. The spectrogram of EEG evoked by laser stimulation was similar to that evoked by mechanical stimulation; alpha ERD and beta ERS were present over the sensorimotor area in response to laser as well as mechanical stimuli. A decoding analysis revealed that classification error increased when discriminating ERD/S patterns between laser and mechanical stimuli, compared to the case of discriminating between laser and sham, or mechanical and sham stimuli. Our neurophysiological results confirm that tactile sensation can be evoked by the plasma effect induced by laser in the air, which may provide a mid-air haptic stimulation method.

6.
Brain Sci ; 11(6)2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34073824

RESUMO

This study aims to use functional magnetic resonance imaging (fMRI) to assess the effective connectivity between the regions of the brain activated when driving and performing a secondary task (addition task). The subjects used an MR-compatible driving simulator ㅊ to manipulate the driving wheel with both hands and control the pedals (accelerator and brake) with their right foot as if they were driving in an actual environment. Effective connectivity analysis was performed for three regions of the right and the left hemispheres with the highest z-scores, and six of the regions of the entire brain (right and left hemisphere) activated during driving by dynamic causal modeling (DCM). In the right hemisphere, a motor control pathway related to movement control for driving performance was discovered; in the left hemisphere, the pathways in the regions related to movement control for driving performance, starting with the region associated with the secondary task, were discovered. In the whole brain, connectivity was discovered in each of the right and left hemispheres. The motor network of declarative memory, which is the connectivity of the right thalamus, left lingual gyrus, and right precentral gyrus, was worth noting. These results seem meaningful, as they demonstrate the connectivity associated with the control of voluntary movement related to memory from human experience, although limited to driving tasks.

7.
Technol Health Care ; 28(S1): 327-334, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32364165

RESUMO

BACKGROUND: The defibrillator is a device that instantaneously discharges the high energy stored in the capacitor to the human body to help revitalize the heart. The circuit for charging the capacitor uses the same power source as the biosignal measurement unit. Therefore, variation in main power supply voltage, ground noise, and electromagnetic interference from the charging circuit can induce distortion into the biosignal at the initial stage of charging. OBJECTIVE: In this study, a simple method is proposed for removing the initial irregularity of an electrocardiogram due to the transient state of a power supply. METHODS: To evaluate the method, a 1-channel electrocardiogram measurement unit and peripheral units were separated from the main control module using galvanic isolation. An isolated push-pull converter was designed to power the secondary side. The method was tested under steady-state and transient conditions. RESULTS: The obtained results proved that biosignal distortion can be significantly reduced. CONCLUSION: This method could be another simple implementation approach for solving signal distortions due to the transient status of power supplies used in medical devices.


Assuntos
Desfibriladores , Fontes de Energia Elétrica , Eletrocardiografia/instrumentação , Simulação por Computador , Capacitância Elétrica , Fenômenos Eletromagnéticos , Desenho de Equipamento , Humanos
8.
Technol Health Care ; 28(S1): 401-410, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32364173

RESUMO

BACKGROUND: Microscopic image analysis based on image processing is required for quantitative evaluation of decellularization. Existing methods are not widely used because of expensive commercial software, and machine learning-based techniques lack generality for decellularization because many high-resolution image data has to be processed. OBJECTIVE: In this study, we developed an image processing algorithm for quantitative analysis of tissues and cells in a general microscopic image. METHODS: The proposed method extracts the color images obtained by the microscope into reference images consisting of grayscale, red (R), green (G), and blue (B) information and transforms each into a binary image. The transformed images were extracted by separating the cells and tissues through outlier noise elimination, logical multiplication and labeling. In order to verify the method, decellularization of porcine arotic valve was performed by the electrical method. Slice samples were obtained by time and the proposed method was applied. RESULTS: The experimental results show that the segmentation of cells and tissues, and quantitative analysis of the number of cells and changes in tissue area during the decellularization process was possible. CONCLUSIONS: The proposed method shows that cell and tissue extraction and quantitative numerical analysis were possible in different brightness of microscopic images.


Assuntos
Algoritmos , Valva Aórtica/patologia , Células/patologia , Cor , Processamento de Imagem Assistida por Computador/métodos , Animais , Reconhecimento Automatizado de Padrão/métodos , Suínos
9.
Sci Rep ; 8(1): 15482, 2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30341331

RESUMO

A facile procedure for compositional screening of chalcogenide glass (CG) is proposed to manage its infrared transmission edge (ωc) as well as refractive index dispersion (ν) in the long-wavelength infrared (LWIR) range. Both ωc and ν of CG turn out to be interpretable simply in connection with its chemical composition based on a postulation that CG behaves as a single average harmonic oscillator (SAHO). In this SAHO model, ωc is expressed as a function of molar mass and average bond energy, both of which are easily accessible for a given CG composition. Two prototypical CG-forming systems in Ge-Sb-Se and Ge-Sb-S compositions exemplify the empirical compositional dependence of ωc, which further plays a decisive role in determining ν. Following the present approach, a set of highly dispersive CG compositions in the Ge-Sb-S system is newly unveiled together with low-dispersion Ge-Sb-Se glasses. It is then experimentally demonstrated that a doublet lens configuration consisting of convex and concave lenses with low and high ν values, respectively, is able to reduce the optical aberrations. This finding presents an opportunity that ν can be envisaged just based on the compositional ratio of CG, thus facilitating completion of the LWIR Abbe diagram.

10.
Technol Cancer Res Treat ; 16(4): 488-496, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27079209

RESUMO

Irreversible electroporation has clinically been used to treat various types of cancer. A plan on how to apply irreversible electroporation before practicing is very important to increase the ablation area and reduce the side effects. Several electrical models have been developed to predict the ablation area with applied electric energy. In this experiment, the static relationship between applied electric energy and ablated area was mathematically and experimentally investigated at 10 hours after applying irreversible electroporation. We performed the irreversible electroporation on the liver tissue of Sprague Dawley rats (male, 8 weeks, weighing 250-350 g). The ablated area was measured based on histological analysis and compared with the mathematical calculation from the electric energy, assuming that the tissue is homogeneous. The ablated area increased with the increase in applied electric energy. The numerically calculated contour lines of electric energy density overlapped well with the apoptotic area induced by the irreversible electroporation. The overlapped area clearly showed that the destructive threshold of apoptosis between electrodes is electric energy density level of 5.9 × 105 J/m3. The results of the present study suggested that the clinical results of the irreversible electroporation on a liver tissue could be predicted through mathematical calculation.


Assuntos
Fígado/cirurgia , Técnicas de Ablação , Algoritmos , Animais , Apoptose , Eletroporação , Marcação In Situ das Extremidades Cortadas , Fígado/patologia , Masculino , Modelos Biológicos , Modelos Estatísticos , Ratos Sprague-Dawley
11.
Biomed Mater Eng ; 26 Suppl 1: S833-40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26406081

RESUMO

The change of neuronal activation due to the passive perception of various driving speeds in comparison to a reference driving speed was assessed using functional Magnetic Resonance Imaging. Videos recorded in real driving conditions on the road at driving speeds of 50, 70, 90, and 110 km/h were shown as visual stimuli. An experiment consisted of three blocks, each having a control phase (50km/h) and a stimulation phase (70, 90, or 110 km/h). In the passive perception of various driving speed differences, the areas related to visual cognition and spatial attention such as temporal, occipital, parietal, frontal areas, and cerebellum were activated. As the driving speed difference increased, the number of activated voxels also increased in the areas related to visual cognition. However, the visual cognition related areas showed a different pattern from the spatial attention related area with an increase of the driving speed difference. This implies that each brain area has a different level of involvement in the passive perception of the driving speed difference, although both visual cognitions related areas and spatial attention related area are related to it.


Assuntos
Atenção/fisiologia , Condução de Veículo , Encéfalo/fisiologia , Cognição/fisiologia , Desempenho Psicomotor/fisiologia , Percepção Visual/fisiologia , Adulto , Mapeamento Encefálico , Feminino , Humanos , Masculino , Rede Nervosa/fisiologia
12.
Biomed Mater Eng ; 24(6): 3619-27, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25227076

RESUMO

In this study, a tactile stimulator that could separately or simultaneously display the vibrotactile and pressure sense was developed. The developed system consisted of a control unit, a drive unit, and an actuator, and can be operated with PC or manually. This system quantitatively controls the stimulation parameters such as the stimulation intensity, duration, frequency, and stimulation type. A preliminary electroencephalogram (EEG) experiment for three types of stimulation (vibrotactile, pressure sense, vibrotactile + pressure sense) highlights that the system could be used in complex tactile cognitive studies. An event-related desynchronization (ERD) and synchronization (ERS) were measured at the area of C3 and C4 for all three types of stimulation, and a clear response was identified in the contralateral somatosensory area from the brain topology. Therefore, it is expected that this system could be widely used in single and complex human tactile cognition and perception studies for vibrotactile and pressure sensation.


Assuntos
Cognição/fisiologia , Sistemas Microeletromecânicos/instrumentação , Estimulação Física/instrumentação , Pressão , Córtex Somatossensorial/fisiologia , Tato/fisiologia , Vibração , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Potenciais Somatossensoriais Evocados/fisiologia , Feminino , Humanos , Imãs , Masculino , Estresse Mecânico
13.
Biomed Mater Eng ; 24(1): 987-91, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211988

RESUMO

The purpose of this study was to investigate the relation between response time of visual matching task and heart rate (HR) in children with Attention Deficit Hyperactivity Disorder (ADHD). Thirty boys who were diagnosed with ADHD and are under treatment participated in the study. The experiment consisted of three phases, a total of 5 min with rest phase, control phase, and visual matching task phase. HR was measured during each phase. The HR in visual matching task phase increased, compared to that in rest phase. There was a negative correlation between response time of visual matching task and magnitude of the HR in the visual matching task phase. In other words, as HR increased, response time of the visual matching task decreased. This means that increasing in HR increased the supply of oxygen by fast circulation of blood for cognitive processing and this induced the improvement of cognitive ability in the ADHD children. This means that increasing HR increased the supply of oxygen by fast circulation of blood for cognitive processing and this induced the improvement of cognitive ability in the ADHD children. The result of this study supports previous studies that the administration of high oxygen concentration can positively affect the cognitive performance of the ADHD children. The results of the present and previous studies also may provide scientific evidence that can be used for treating patients with cognitive problems such as ADHD.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/sangue , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Frequência Cardíaca , Oxigênio/sangue , Tempo de Reação , Visão Ocular , Criança , Cognição , Humanos , Masculino , Testes Neuropsicológicos , Estimulação Luminosa , Reprodutibilidade dos Testes , Fatores de Tempo
14.
Behav Res Methods ; 46(2): 396-405, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23861087

RESUMO

For this study, we developed a simple pressure and heat stimulator that can quantitatively control pressure and provide heat stimulation to intra- and interdigit areas. The developed stimulator consists of a control unit, drive units, and tactors. The control unit controls the stimulation parameters, such as stimulation types, intensity, time, and channel, and transmits a created signal of stimulation to the drive units. The drive units operate pressure and heat tactors in response to commands from the control unit. The pressure and heat tactors can display various stimulation intensities quantitatively, apply stimulation continuously, and adjust the stimulation areas. Additionally, they can easily be attached to and detached from the digits. The developed pressure and heat stimulator is small in total size, easy to install, and inexpensive to manufacture. The new stimulator operated stably in a magnetic resonance imaging (MRI) environment without affecting the obtained images. A preliminary functional magnetic resonance imaging (fMRI) experiment confirmed that differences in activation of somatosensory areas were induced from the pressure and heat stimulation. The developed pressure and heat stimulator is expected to be utilized for future intra- and interdigit fMRI studies on pressure and heat stimulation.


Assuntos
Dedos/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Estimulação Física/instrumentação , Percepção do Tato/fisiologia , Adulto , Desenho de Equipamento , Temperatura Alta , Humanos , Masculino , Pressão , Processamento de Sinais Assistido por Computador , Adulto Jovem
15.
Cogn Neurosci ; 4(1): 1-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24073694

RESUMO

This study investigated how three levels of arousal affected performance of a 3-back working memory task. Ten female and ten male university students participated in this experiment. With pictures selected from a group test, three levels of arousal were induced--i.e., tense, neutral, and relaxed emotions. Each subject was run through the procedure three times, once for each arousal level. The procedure consisted of six phases for each arousal condition: (1) Rest 1 (2 min), (2) Picture 1 (presenting emotion arousing photos for 2 min), (3) 3-back working memory task 1 (2 min), (4) Picture 2 (presenting emotion-arousing photos for 2 min), (5) 3-back working memory task 2 (2 min), and (6) Rest 2 (2 min). The skin conductance level of electrodermal activity was also measured during all phases of the experiment. The accuracy rate of 3-back working memory task performance was the highest at a neutral emotional state, followed by relaxed and then tense emotional states. There were no significant differences in reaction time.


Assuntos
Nível de Alerta/fisiologia , Emoções/fisiologia , Resposta Galvânica da Pele/fisiologia , Memória de Curto Prazo/fisiologia , Adulto , Feminino , Humanos , Masculino , Testes Neuropsicológicos , Estimulação Luminosa/métodos , Tempo de Reação , Adulto Jovem
16.
NeuroRehabilitation ; 32(3): 687-92, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23648624

RESUMO

BACKGROUND: This study attempted to identify the effect of administration of highly concentrated oxygen on simple visual matching task performance, blood oxygen saturation [SpO2 (%)], and heart rate [HR (bpm)] of intellectually and developmentally disabled people. METHODS: Nineteen intellectually and developmentally disabled people (mean age 30.6 ± 5.7 years) participated in an experiment consisting of a simple visual matching task performed under 21% and 92% oxygen. SpO2 and HR were measured under both oxygen conditions. RESULTS: When 92% oxygen was supplied, the response time decreased, SpO2 increased, and HR decreased compared to the vales obtained using 21% oxygen. The response time decreased for subjects with a high SpO2 and HR during the simple visual matching task phase. CONCLUSION: This result supports the hypothesis that administration of highly concentrated oxygen can positively affect the cognitive performance of intellectually and developmentally disabled people.


Assuntos
Aprendizagem por Associação/fisiologia , Deficiências do Desenvolvimento/terapia , Oxigenoterapia Hiperbárica/métodos , Deficiência Intelectual/terapia , Adulto , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Testes Neuropsicológicos , Oxigênio/sangue , Consumo de Oxigênio , Estimulação Luminosa , Tempo de Reação , Adulto Jovem
17.
Biochem Biophys Res Commun ; 435(4): 651-6, 2013 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-23688425

RESUMO

Irreversible electroporation is a novel method of ablating living tissues through its non-thermal effects, unlike radiofrequency ablation which has a severe problem of heat sink. It is due to high-energy direct current which leads to permanent disruption of lipid bilayer integrity in terms of exchanges between intra- and extracellular components via nano-sized pores. That finally causes irreversible damage to cellular homeostasis. Irreversibly damaged cells may undergo apoptosis followed by necrosis with time after electroporation. This damage can make it possible to monitor the ablated area with time post-IRE through MR imaging and an ultrasound system. Most previous studies have investigated the immediate response of undesired tissue to IRE. In our study, we showed changes of tumor tissues with time post-IRE by histological analysis and MR imaging. Tissues under IRE ablation showed a peak apoptotic rate at 24 h after IRE ablation with viable tissues at the peripheral rim of treated tissues in histological analysis. This phenomenon was also observed with no enhancement on contrast-enhanced MR images due to devascularization of IRE ablated zones.


Assuntos
Eletroporação/métodos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia , Animais , Apoptose/efeitos da radiação , Linhagem Celular Tumoral , Feminino , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias da Próstata/fisiopatologia , Resultado do Tratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-22149159

RESUMO

In this study, a tactile stimulator was developed, which can stimulate visual and auditory senses simultaneously by using the E-Prime software. This study tried to compensate for systematic stimulation control and other problems that occurred with previously developed tactile stimulators. The newly developed system consists of three units: a control unit, a drive unit and a vibrator. Since the developed system is a small, lightweight, simple structure with low electrical consumption, a maximum of 35 stimulation channels and various visual and auditory stimulation combinations without delay time, the previous systematic problem is corrected in this study. The system was designed to stimulate any part of the body including the fingers. Since the developed tactile stimulator used E-Prime software, which is widely used in the study of visual and auditory senses, the stimulator is expected to be highly practical due to a diverse combination of stimuli, such as tactile-visual, tactile-auditory, visual-auditory and tactile-visual-auditory stimulation.


Assuntos
Estimulação Acústica/instrumentação , Estimulação Luminosa/instrumentação , Software , Tato/fisiologia , Desenho de Equipamento , Dedos , Humanos
19.
Behav Res Methods ; 45(2): 364-71, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23055173

RESUMO

For this study, we developed a magnetic resonance (MR)-compatible vibrotactile stimulator using a planar-coil-type actuator. The newly developed vibrotactile stimulator consists of three units: control unit, drive unit, and planar-coil-type actuator. The control unit controls frequency, intensity, time, and channel, and transfers the stimulation signals to the drive unit. The drive unit operates the planar-coil-type actuator in response to commands from the control unit. The planar-coil-type actuator, which uses a planar coil instead of conventional electric wire, generates vibrating stimulation through interaction of the current of the planar coil with the static magnetic field of the MR scanner. Even though the developed tactile stimulating system is small, simple, and inexpensive, it has a wide range of stimulation frequencies (20 ~ 400 Hz, at 40 levels) and stimulation intensities (0 ~ 7 V, at 256 levels). The stimulation intensity does not change due to frequency changes. Since the transient response time is a few microseconds, the stimulation time can be controlled on a scale of microseconds. In addition, this actuator has the advantages of providing highly repeatable stimulation, being durable, being able to assume various shapes, and having an adjustable contact area with the skin. The new stimulator operated stably in an MR environment without affecting the MR images. Using functional magnetic resonance imaging, we observed the brain activation changes resulting from stimulation frequency and intensity changes.


Assuntos
Imageamento por Ressonância Magnética/métodos , Estimulação Física/instrumentação , Vibração , Adulto , Encéfalo/fisiologia , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Imagens de Fantasmas , Tato/fisiologia
20.
Geriatr Gerontol Int ; 13(2): 384-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22817401

RESUMO

AIM: This study investigated the correlation between response time of the 1-back task and changes of blood oxygen saturation (SpO2 ) by supplying three different levels of oxygen (21%, 1 L/min; 93%, 1 L/min; 93%, 5 L/min) in the elderly. METHODS: A total of 17 older adults (mean age 72.9 ± 4.7 years) participated in the experiment. A 1-back task was used as a cognitive task. The experiment consisted of three phases, which included the adaptation phase (3 min) after oxygen administration, the control phase (2 min) that maintained a stable condition before the task, and the task phase (2 min) where the 1-back task was carried out. SpO2 was measured during each phase. RESULTS: As concentration level and supply of oxygen increased, SpO2 increased and response time of the 1-back task decreased. CONCLUSION: Highly concentrated oxygen administration can increase SpO2 in the elderly and an increase in cognitive performance, such as a decrease in response time, can be observed.


Assuntos
Cognição/fisiologia , Oxigenoterapia/métodos , Oxigênio/sangue , Tempo de Reação/fisiologia , Adaptação Fisiológica/fisiologia , Idoso , Feminino , Humanos , Masculino , Memória/fisiologia , Oximetria/instrumentação , Oxigênio/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...