Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1021787

RESUMO

BACKGROUND:Medial open wedge high tibial osteotomy is an effective procedure for preserving the knee joint in patients with medial compartmental osteoarthritis.Previous studies have demonstrated that the forgotten joint score provides a lower ceiling effect and consistency of medial open wedge high tibial osteotomy outcomes compared to traditional assessment tools. OBJECTIVE:To identify predictive factors associated with the occurrence of a forgotten joint after medial open wedge high tibial osteotomy. METHODS:117 patients with medial open wedge high tibial osteotomy who were treated at First Affiliated Hospital of Guangzhou University of Chinese Medicine were selected,including 35 males and 82 females,with an average age of 61 years.They were followed up for at least 2 years.Patients were divided into a forgotten joint group(n=28)and a non-forgotten joint group(n=89)by evaluating whether they achieved forgotten joint after surgery.Univariate and multivariate logistic regression analyses were performed with preoperative patient characteristics and surgery-related factors as potential predictors. RESULTS AND CONCLUSION:(1)There were significant differences in the proximal medial tibial angle between the two groups before surgery(P<0.05).There were significant differences in the forgotten joint score,Knee Injury and Osteoarthritis Outcome Score,knee society knee score,function score,and patients joint perception between the two groups after surgery(P<0.05).There was a significant difference between the hip-knee-ankle angle and the medial proximal tibial angle after operation(P<0.05).(2)Univariate Logistic regression analysis showed that the medial proximal tibial angle had a significant influence on the forgotten joint before operation[OR=0.755,95%CI(0.635-0.897),P<0.001].There were significant effects on the forgotten joint of hip-knee-ankle angle and medial proximal tibial angle[OR=1.546,95%CI(1.242-1.924),P<0.001;OR=0.815,95%CI(0.713-0.931),P=0.003].(3)Multivariate logistic regression analysis showed that preoperative K-L grade 1 was a favorable factor for obtaining forgotten joints.Preoperative medial proximal tibial angle and postoperative hip-knee-ankle angle were independent predictors of forgetting joints,and they had a curvilinear relationship with the probability of achieving forgetting joints.When preoperative medial proximal tibial angle increased by 1°,the probability of achieving a forgotten joint decreased by 27.7%[OR=0.723,95%CI(0.593-0.882),P<0.001].Conversely,when postoperative hip-knee-ankle angle increased by 1°,the probability of achieving a forgotten joint increased by 46.4%[OR=1.464,95%CI(1.153-1.860),P=0.002].(4)The results showed that patients with preoperative knee osteoarthritis K-L grade 1,small medial proximal tibial angle(<85.5°),and large postoperative hip-knee-ankle angle(>176.0°)were predictors of forgotten joint.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-508495

RESUMO

BACKGROUND:Searching for a porous three-dimensional (3D) scaffold holding good porosity, mechanical property and biocompatibility has become a hot spot, in which, 3D printing technology also plays apart. OBJECTIVE:To prepare silk fibroin/col agen scaffolds using 3D printing technology and detect its performance. METHODS:Silk fibroin/col agen scaffolds were constructed using 3D printing technology, and the silk fibroin/col agen mass ratio was 4:2 (group A) and 4:4 (group B), respectively. The porosity, water absorption expansion rate, mechanical properties and pore size of the composite scaffolds were detected. The passage 3 rat bone marrow mesenchymal stem cel s were seeded onto the two scaffolds. The cel proliferation was detected using MTT assay at 13 days of culture, and the cel morphology was observed by hematoxylin-eosin staining and scanning electron microscope at 14 days of culture. RESULTS AND CONCLUSION:The porosity, pore size, and water absorption expansion rate of group A were significantly larger than those of group B (P<0.05), while the elasticity modulus showed no significant difference between groups. Bone marrow mesenchymal stem cel s on the two scaffolds increased gradual y with time, especial y in the group A (P<0.05). Abundant cel s distributed evenly in the group A, while few cel s distributed unevenly in the group B. These results suggest that the 3D printed scaffolds composed by silk fibroin/col agen mass ratio of 4:2 holds good physicochemical performance and cytocompatibility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA