Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Vaccine ; 41(9): 1545-1549, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36732167

RESUMO

Longitudinal data on the immune response from the first dose to several months after the third dose of COVID-19 vaccine are limited. We analyzed the immune response in 406 Japanese healthcare workers who received at least three doses of vaccine. The geometric mean anti-receptor binding domain IgG antibody titers and antigen-stimulated T-cell interferon-gamma levels after 6 months after receiving a third dose were similar to those 8 weeks after receiving a second dose. Humoral and cellular immunity induced by the third dose was more durable than that induced by the second dose. UMIN Clinical Trials Registry ID: UMIN000043340.


Assuntos
Vacina BNT162 , COVID-19 , Imunidade Celular , Imunidade Humoral , Humanos , Anticorpos Antivirais , Vacina BNT162/imunologia , COVID-19/prevenção & controle , População do Leste Asiático , Pessoal de Saúde
2.
Int J Lab Hematol ; 44(6): 1050-1059, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36380469

RESUMO

INTRODUCTION: Assessing the percentage of reticulocytes (%Retic) is useful for diagnosing and treating blood diseases that present with anaemia. The Celltac G+™ hematology analyzer (HA) uses a novel reticulocyte identification method that involves metachromatic nucleic acid staining with acridine orange and crossover analysis of emission light of DNA/RNA (determination of red cells, nucleic acid-containing cells, and platelets, RNP Determination™). The red and green fluorescence generated by stained single-stranded RNA and double-stranded DNA express immaturity and morphological abnormality of erythrocytes by detecting erythrocyte RNA and DNA content. METHODS: The basic performance of the test automated analyzer (TAA) Celltac G+ was evaluated and compared with the flow cytometry reference method and the comparative automated analyzer (CAA) XN-1000/2000™. In addition, its precision, limit of quantity (LoQ), linearity, analytical measurement interval (AMI), accuracy, and comparability and the effects of interfering substances were evaluated. RESULTS: Evaluation of %Retic by the TAA demonstrated good precision and linearity. The AMI was confirmed from 0.02 to 8.23, and the LoQ in %Retic as the coefficient of variation within an 11% limit (SD, within a 0.01 limit) was 0.14. TAA correlated well with the reference method and routine HA (CAA). Some deviations were found between TAA and CAA in DNA measurements of erythrocytes from abnormal samples. CONCLUSION: Celltac G+ uses a novel measurement principle and can assess erythrocyte immaturity independent of DNA contents. It represents a new HA that provides novel, useful information on immaturity and morphological abnormality of erythrocytes.


Assuntos
Hematologia , Ácidos Nucleicos , Humanos , Reticulócitos , RNA , Reprodutibilidade dos Testes , DNA , Coloração e Rotulagem
3.
Eur J Immunol ; 52(12): 1961-1971, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36250411

RESUMO

Memory T cell responses have been analyzed only in small cohorts of COVID-19 vaccines. Herein, we aimed to assess anti-SARS-CoV-2 cellular immunity in a large cohort using QuantiFERON assays, which are IFN-γ release assays (IGRAs) based on short-term whole blood culture. The study included 571 individuals receiving the viral spike (S) protein-expressing BNT162b2 mRNA vaccine. QuantiFERON assays revealed antigen-specific IFN-γ production in most individuals 8 weeks after the second dose. Simultaneous flow cytometric assays to detect T cells expressing activation-induced markers (AIMs) performed for 28 randomly selected individuals provided data correlating with the QuantiFERON data. Simultaneous IFN-γ enzyme-linked immunospot and AIM assays for another subset of 31 individuals, based on short-term peripheral blood mononuclear cell culture, also indicated a correlation between IFN-γ production and AIM positivity. These observations indicated the acquisition of T cell memory responses and supported the usability of IGRAs to assess cellular immunity. The QuantiFERON results were weakly correlated with serum IgG titers against the receptor-binding domain of the S protein and were associated with pre-vaccination infection and adverse reactions after the second dose. The present study revealed cellular immunity after COVID-19 vaccination, providing insights into the effects and adverse reactions of vaccination.


Assuntos
COVID-19 , Vacinas , Humanos , Vacinas contra COVID-19 , SARS-CoV-2 , Vacina BNT162 , Leucócitos Mononucleares , COVID-19/prevenção & controle , Imunidade Celular
4.
Vaccine ; 40(32): 4538-4543, 2022 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-35718591

RESUMO

BACKGROUND: The antibody titer is known to wane within months after receiving two doses of the Pfizer-BioNTech BNT162b2 mRNA SARS-CoV-2 vaccine. However, knowledge of the cellular immune response dynamics following vaccination is limited. This study to aimed to determine antibody and cellular immune responses following vaccination, and the incidence and determinants of breakthrough infection. METHODS: This prospective cohort study a 6-month follow-up period was conducted among Japanese healthcare workers. All participants received two doses of BNT162b2 vaccine. Anti-SARS-CoV-2 antibody titers and T-cell immune responses were measured in serum samples collected at several timepoints before and after vaccination. RESULTS: A total of 608 participants were included in the analysis. Antibody titers were elevated 3 weeks after vaccination and waned over the remainder of the study period. T-cell immune responses showed similar dynamics. Six participants without predisposing medical conditions seroconverted from negative to positive on the IgG assay for nucleocapsid proteins, indicating breakthrough SARS-CoV-2 infection. Five of the six breakthrough infections were asymptomatic. CONCLUSIONS: Both humoral and cellular immunity waned within 6 months after BNT162b2 vaccination. The incidence of asymptomatic breakthrough infection within 6 months after vaccination was approximately one percent. UMIN CLINICAL TRIALS REGISTRY ID: UMIN000043340.


Assuntos
Vacina BNT162 , COVID-19 , Anticorpos Antivirais , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Pessoal de Saúde , Humanos , Imunidade Celular , Japão , Estudos Prospectivos , SARS-CoV-2 , Vacinas Sintéticas , Vacinas de mRNA
5.
Vaccine ; 40(7): 1019-1025, 2022 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-35033389

RESUMO

BACKGROUND: SARS-CoV-2 vaccination has started worldwide, including Japan. Although high rates of vaccine response and adverse reactions of BNT162b2 vaccine have been reported, knowledge about the relationship between sex differences and antibody response is limited. Furthermore, it is uncertain whether adverse reactions are associated with the vaccine response. METHODS: This prospective observational study included 673 Japanese participants working in a medical school and its affiliated hospital in Tokyo, Japan (UMIN000043340). Serum samples were collected before the first dose and three weeks after the second dose of BNT162b2 vaccine, and antibody titers against the receptor-binding domain of the spike protein of SARS-CoV-2 were measured. Answers to questionnaires about background characteristics and adverse reactions were obtained at the time of sample collection, and the relationship between antibody titers was analyzed. RESULTS: After excluding participants who did not complete receiving two doses of vaccination or two series of serum sample collection, 646 participants were analyzed. Although all participants became sero-positive after vaccination, antibody titers were highly variable among individuals (260.9-57,399.7A U/mL), with a median titer of 13478.0AU/mL. Mean titer was higher in females than in males and higher in young (≤45 years old) participants than in aged (>45 years old) participants. Participants who experienced adverse reactions demonstrated a higher antibody titer after vaccination than those without adverse reactions. Multivariable analysis demonstrated that young age, female sex, and adverse reactions after the second dose were independently related to higher antibody titers after the second dose. DISCUSSION: A favorable antibody response was observed after two doses of BNT162b2 vaccination among mostly healthy Japanese participants, especially among female and young participants. Although further investigation is essential, our results imply that the systemic adverse reactions (i.e., fever and general fatigue) are associated with a higher antibody response that indicates the acquisition of humoral immunity.


Assuntos
Vacina BNT162 , COVID-19 , Anticorpos Antivirais , Vacinas contra COVID-19 , Feminino , Pessoal de Saúde , Humanos , Japão , Masculino , Pessoa de Meia-Idade , RNA Mensageiro , SARS-CoV-2 , Universidades , Vacinação
6.
Clin Chim Acta ; 521: 278-284, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34331951

RESUMO

BACKGROUND: Presepsin is a diagnostic and prognostic biomarker of both bacterial infection and sepsis; however, elevated presepsin levels have also been observed without sepsis. We conducted several analyses to evaluate the clinical laboratory parameters affecting presepsin levels. METHOD: We analyzed the association between sequential organ failure assessment (SOFA) scores and plasma presepsin levels and then analyzed clinical laboratory parameters in 567 patients with univariate and multivariate regression analysis and analysis of covariance (ANCOVA). We also determined presepsin in the bile of 11 patients and examined the presepsin immunostaining in liver. RESULTS: Spearman's rank correlation analysis with loge change revealed that presepsin levels were closely associated with loge-transformed SOFA score (ρ = 0.541), alkaline phosphatase (ALP); (ρ = 0.454) and gamma-glutamyl transferase; (ρ = 0.505). Multivariate regression analysis revealed that loge-transformed SOFA score (ß-coefficient = 0.316), ALP level (ß-coefficient = 0.380), and creatinine level (ß-coefficient = 0.290) independently and significantly affected loge presepsin levels. ANCOVA revealed that presepsin levels were significantly higher in patients with hepatobiliary disease. Patients who presented with dilatation of the bile ducts and elevated ALP levels or total bilirubin levels exhibited high presepsin levels in the bile. Presepsin production in liver Kupffer cells was also confirmed by immunostaining. CONCLUSION: Presepsin levels is correlated with the elevation of biliary enzymes in patients without renal dysfunction or sepsis. Additionally, presepsin exists with high concentrations in the bile and is positive in Kupffer cells.


Assuntos
Doenças Biliares , Sepse , Bile , Doenças Biliares/diagnóstico , Biomarcadores , Humanos , Receptores de Lipopolissacarídeos , Fragmentos de Peptídeos , Estudos Retrospectivos , Sepse/diagnóstico
7.
J Infect Chemother ; 27(7): 1058-1062, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33934920

RESUMO

INTRODUCTION: Rapid antigen detection (RAD) tests are convenient tools for detecting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in clinics, and testing using saliva samples could decrease the risk of infection during sample collection. This study aimed to assess the accuracy of the SARS-CoV-2 RAD for testing of nasopharyngeal swab specimens and saliva samples in comparison with the RT-PCR tests and viral culture for detecting viable virus. METHODS: One hundred seventeen nasopharyngeal swab specimens and 73 saliva samples with positive results on RT-PCR were used. Residual samples were assayed using a commercially available RAD test immediately, and its positivity was determined at various time points during the clinical course. The concordance between 54 nasopharyngeal swab samples and saliva samples that were collected simultaneously was determined. Viral culture was performed on 117 samples and compared with the results of the RAD test. RESULTS: The positive rate of RAD test using saliva samples was low throughout the clinical course. Poor concordance was observed between nasopharyngeal swab specimens and saliva samples (75.9%, kappa coefficient 0.310). However, a substantially high concordance between the RAD test and viral culture was observed in both nasopharyngeal swab specimens (86.8%, kappa coefficient 0.680) and saliva samples (95.1%, kappa coefficient 0.643). CONCLUSIONS: The sensitivity of the SARS-CoV-2 RAD test was insufficient, particularly for saliva samples. However, a substantially high concordance with viral culture suggests its potential utility as an auxiliary test for estimating SARS-CoV-2 viability.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Saliva
8.
Ann Clin Biochem ; 58(4): 368-376, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33730868

RESUMO

BACKGROUND: Quantitative antibody tests are expected to be useful in diagnostics of COVID-19 and investigation of herd immunity against SARS-CoV-2. To make it proper to perform them, understanding of the immunological aspects is critically important. The present study aimed to assess humoral responses in COVID-19 using various quantitative antibody tests. METHODS: Four quantitative antibody tests that are different in targeted antigens, detectable immunoglobulin classes and avidity were used. Diagnosis was confirmed by RT-PCR for SARS-CoV-2 detection. Antibody titres of 117 samples collected from 24 COVID-19 patients and 23 non-COVID-19 patients were measured to evaluate correlations between different tests. For 24 COVID-19 patients, antibody titres measured at various time points after the onset or the RT-PCR diagnosis were subjected to assessment of humoral responses. RESULTS: Correlations between tests were observed to some degree, although there were discrepancies putatively due to differences in measurement principle. Seronegative COVID-19 was diagnosed for some patients, in whom antibody titres were less than the cut-off value in each test throughout the time courses. IgG seroconversion without prior IgM seroconversion most frequently occurred, while predominance of IgM responses over IgG responses was observed in some severe cases. Viral burdens estimated according to threshold cycle values at the RT-PCR seemed to impact antibody responses. CONCLUSIONS: The results provide insights into the nature of humoral responses to SARS-CoV-2 and diagnostic performance of antibody tests.


Assuntos
Anticorpos Antivirais , Teste de Ácido Nucleico para COVID-19 , Teste Sorológico para COVID-19 , COVID-19 , Imunidade Humoral , Imunoglobulina G , Imunoglobulina M , SARS-CoV-2 , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Masculino , SARS-CoV-2/imunologia , SARS-CoV-2/metabolismo
9.
Ann Clin Biochem ; 58(3): 174-180, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33334135

RESUMO

BACKGROUND: The usability of laboratory tests related to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critically important for the world undergoing the COVID-19 pandemic. The present study aimed to assess the diagnostic usability of rapid tests for the detection of antibody against SARS-CoV-2 through comparison of their results with the results of reverse transcription polymerase chain reaction (RT-PCR) test for the detection of SARS-CoV-2 genomic RNA and with the results of a quantitative test for antibody detection. METHODS: Serum samples were collected from 18 patients undergoing RT-PCR testing for SARS-CoV-2. Twelve patients were RT-PCR positive while six were negative. A quantitative test based on chemiluminescent immunoassay and three rapid tests based on immunochromatography were performed to detect anti-SARS-CoV-2 IgG and IgM. RESULTS: All the antibody tests exhibited poor sensitivity at the timing of initial RT-PCR diagnosis. IgG responses occurring prior to or simultaneously with IgM responses were observed through not only the quantitative test but also the three rapid tests. Based on concordance with the quantitative test results, the large variance among the three rapid tests was revealed. CONCLUSIONS: All antibody tests were unsatisfactory to replace RT-PCR for the early diagnosis of COVID-19. Rapid antibody tests as well as a quantitative antibody test were useful in the assessment of immune responses in COVID-19. The obvious variance among the three rapid tests suggested limited accuracy and difficult standardization. Diagnostic usability of rapid antibody tests for COVID-19 should be investigated rigorously.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19 , COVID-19/sangue , SARS-CoV-2/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
11.
World J Clin Cases ; 8(22): 5657-5662, 2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33344557

RESUMO

BACKGROUND: In myelodysplastic syndrome (MDS), oxidative stress is closely related to iron overload and DNA damage. A recent study suggested the possibility that increased oxidative stress causes not only iron overload but also disease progression of MDS with DNA damage. We present a case of MDS with decreased reactive oxygen species (ROS) production in peripheral white blood cells (WBCs) and decreased diacron-reactive oxygen metabolites (d-ROMs) in serum after azacitidine therapy. CASE SUMMARY: A 74-year-old man presented to the hematological department with the chief complaint of anemia. His vital signs were within normal limits at admission with a heart rate of 80 bpm and blood pressure of 135/60 mmHg. Laboratory tests indicated pancytopenia, a WBC count of 2190 cells/µL, a hemoglobin level of 6.2 g/dL and a platelet count of 7.4 × 104/µL. The patient was diagnosed with MDS with fibrosis after a bone marrow examination. This case showed decreased ROS production in WBCs, d-ROMs in serum and Wilms' tumor 1 after azacitidine therapy, after which his hematopoiesis recovered. CONCLUSION: Azacitidine therapy can improve hematopoiesis and decrease ROS and d-ROM production.

13.
Intern Med ; 55(24): 3661-3664, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27980269

RESUMO

Oxidative stress is closely related to iron overload in myelodysplastic syndrome (MDS) and induces DNA damage. We evaluated the oxidative stress markers derivatives of reactive oxidative metabolites (dROM) and 8-hydroxy-2'-deoxyguanosine (8-OHdG) during azacitidine treatment in an MDS patient. Simultaneous with an increase in the expression of Wilms' Tumor 1 (WT1) gene in the peripheral blood, the serum dROM level was elevated, and this increase was observed earlier than the increases in ferritin and 8-OHdG. Throughout the clinical course, dROM and 8-OHdG correlated significantly with WT1 and with ferritin, suggesting that changes in the oxidative stress marker levels reflect not only iron overload but also disease progression of MDS.


Assuntos
Progressão da Doença , Genes do Tumor de Wilms , Síndromes Mielodisplásicas/genética , Estresse Oxidativo , Idoso , Antimetabólitos Antineoplásicos/efeitos adversos , Azacitidina/efeitos adversos , Biomarcadores Tumorais/sangue , Dor no Peito/etiologia , Dano ao DNA , Desferroxamina/uso terapêutico , Evolução Fatal , Ferritinas/sangue , Humanos , Sobrecarga de Ferro/metabolismo , Sobrecarga de Ferro/fisiopatologia , Masculino , Insuficiência de Múltiplos Órgãos , Síndromes Mielodisplásicas/sangue , Síndromes Mielodisplásicas/tratamento farmacológico , Síndromes Mielodisplásicas/fisiopatologia , Sideróforos/uso terapêutico
14.
Rinsho Byori ; 64(11): 1220-1228, 2016 11.
Artigo em Japonês | MEDLINE | ID: mdl-30695302

RESUMO

The immature platelet fraction (IPF%) is a parameter for the automatic quantification of reticulated plate- lets and is considered to reflect platelet production. We evaluated IPF% measurements using an automated analyzer, the Sysmex XN. We measured the platelet counts and the IPF% values in 35 healthy subjects and 275 patients with various diseases using both the XN analyzer and a conventional analyzer, the Sysmex XE. Significant correlations in the platelet count and the IPF% were observed between the XN results and the XE results. In the same samples, significant inverse correlations were observed between the platelet count and the IPF% in both the XN and XE results. The coefficient of variation values for the platelet count and the IPF% measurements obtained using the XN analyzer were lower than those obtained using the XE ana- lyzer. In patients who had undergone hematopoietic stem cell transplantation, the IPF% measurements obtained using the XN analyzer increased several days before platelet recovery. IPF% measurements performed using the XN analyzer are adequate for clinical use. This parameter may be a useful marker for the prediction of platelet recovery. [Original].


Assuntos
Plaquetas/citologia , Contagem de Plaquetas/métodos , Automação Laboratorial , Humanos , Reprodutibilidade dos Testes
15.
Clin Biochem ; 48(10-11): 690-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25863111

RESUMO

OBJECTIVES: Sphingosine 1-phosphate (S1P) is a bioactive sphingolipid mediator. Although the plasma S1P concentration is reportedly determined by cellular components, including erythrocytes, platelets, and vascular endothelial cells, the possible involvement of other factors, such as serum sphingomyelin (SM) and autotaxin (ATX), remains to be elucidated. DESIGN AND METHODS: We measured S1P using high-performance liquid chromatography (HPLC), SM and lysophosphatidic acid (LPA) using enzymatic assays, ATX antigen using a two-site enzyme immunoassay, and ATX activity using a lysophospholipase D activity assay. To fractionate the lipoproteins, plasma samples were separated using fast protein liquid chromatography (FPLC) utilizing a Superose 6 column. RESULTS: The plasma S1P level was positively correlated with the levels of SM and lysophosphatidylcholine, but not with the level of phosphatidylcholine. Although SM was present in the very low-density lipoprotein (VLDL) fraction, neither the plasma S1P level nor the SM level was affected by feeding. The plasma S1P level was negatively correlated with the ATX activity. Although the incubation of 100 µmol/L of sphingosylphosphorylcholine (SPC) with the serum resulted in a significant increase in the S1P level because of the presence of ATX, the physiological concentration of SPC did not mimic this effect. CONCLUSION: The plasma S1P level was affected by the serum SM level, while the possibility of ATX involvement in the increase in the plasma S1P level was considered to be remote at least in healthy human subjects.


Assuntos
Lisofosfolipídeos/sangue , Diester Fosfórico Hidrolases/sangue , Esfingomielinas/sangue , Esfingosina/análogos & derivados , Adulto , Biomarcadores/sangue , Feminino , Humanos , Masculino , Esfingosina/sangue
17.
Rinsho Byori ; 62(4): 315-23, 2014 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-25022060

RESUMO

BACKGROUND: The measurement of antinuclear antibodies (ANA) is used for screening of connective tissue diseases (CTD) in the laboratory. ANA detection is performed by indirect immunofluorescence (IF) assay on HEp-2 cells from human larynx carcinoma. However, it lacks specificity for the identification of specific diseases and antigen reactivity. The aim of the present study was to evaluate the EliA CTD Screen (EliA), a new enzyme fluoroimmunoassay (Phadia AB, Uppsala, Sweden) for detection of ANA in human serum. PATIENTS AND METHODS: The study involved a total of 732 serum samples, 200 from healthy donors, 297 from patients with CTD and 235 from patients with rheumatoid arthritis, vasculitis syndrome and relative disease of CTD. For all sera, ANA was measured by IF, commercial assay (MESACUP) and EliA. RESULT: The sensitivity and specificity of EliA were 73.7% and 78.7%, respectively, whereas those of MESACUP were 80.8% and 64.7%, respectively. Area under the receiver operating curves for EliA, MESACUP and IF were 0.821, 0.786 and 0.730, respectively. The concordance rate between EliA and MESACUP was 84.2%. These discrepancies between those 2 assays were found in 84 sera. Further investigation were done by each ANA antigen tests for the discrepant results of EliA in 83 sera. The discrepancies might be occurred by antigen difference or non-specific response. CONCLUSION: AUC results showed that the diagnostic performance of EliA was superior to MESACUP and IF. EliA had a good performance as method for screening of CTD.


Assuntos
Anticorpos Antinucleares/sangue , Fluorimunoensaio/métodos , Técnicas Imunoenzimáticas/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antinucleares/imunologia , Doenças do Tecido Conjuntivo/sangue , Doenças do Tecido Conjuntivo/diagnóstico , Doenças do Tecido Conjuntivo/imunologia , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade
18.
Rinsho Byori ; 62(4): 369-77, 2014 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-25022066

RESUMO

The pathogenic chromosome translocations present in various hematological malignancies result in the formation of fusion genes, which are detected by a reverse transcription-polymerase chain reaction method. Furthermore, with this method, it is possible to sensitively detect minimal residual disease (MRD), which is difficult by a morphological testing. It has now been established that the detection of MRD is important for the diagnosis, treatment policy, evaluation of the prognosis, and monitoring of leukemia. In particular, quantitative analysis of MRD is important for evaluation of the curative effect and prediction of recurrence. In addition, mutation analysis is valuable to decide on the therapeutic protocol for imatinib-resistant patients, and the stratification of treatment for acute myeloid leukemia. At present, however, there is no standard laboratory procedure for genetic testing for leukemia. Here, the problems related to external precision management and analytical error are discussed.


Assuntos
Testes Genéticos , Neoplasias Hematológicas/genética , Leucemia/genética , Neoplasia Residual/genética , Diagnóstico Diferencial , Testes Genéticos/instrumentação , Neoplasias Hematológicas/diagnóstico , Humanos , Leucemia/diagnóstico , Neoplasia Residual/diagnóstico , Recidiva
19.
PLoS One ; 9(1): e86606, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24466168

RESUMO

BACKGROUND: Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. METHODS: We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. RESULTS: Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. CONCLUSIONS: We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.


Assuntos
Alcaptonúria/urina , Ácido Homogentísico/urina , Hidróxidos/farmacologia , Fenilcetonúrias/urina , Compostos de Potássio/farmacologia , Hidróxido de Sódio/farmacologia , Adulto , Alcaptonúria/diagnóstico , Estudos de Casos e Controles , Feminino , Voluntários Saudáveis , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Oxirredução , Fenilcetonúrias/diagnóstico , Espectrofotometria , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...