Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Asian J Neurosurg ; 15(3): 566-572, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33145208

RESUMO

OBJECTIVE: The objective is to demonstrate change of cerebral perfusion and cerebrovascular reserve (CVR) in treating patients with cerebrovascular steno-occlusive disease stratified by change of cerebral perfusion and CVR. METHODS: Retrospective review patients with radiographic proven major cerebrovascular steno-occlusive disease whom underwent cerebral perfusion imaging with vasoactive stimuli stress test in Siriraj Hospital and Bangkok General Hospital during 2010-2018. Medical records were also reviewed. Radiographic findings, cerebral perfusion parameters and signal change during the stress test were reviewed and used to categorize into three groups. RESULTS: There were 40 patients sent to radiology department for the evaluation of CVR. One patient had airway problem during the procedure and was excluded. Remaining 39 patients were included in this study (32 males and 7 females, mean age of 54.55 years). In 42 sites involved, 28 (66%) were internal carotid artery, 14 (33%) were middle cerebral arteries. Laterality is left side in 20 cases, right side in 14 cases, and bilateral in 5 cases. Poor CVR response (increased cerebral blood flow <10%) was found in 9 patients (2 severe stenoses and 7 total occlusions). The mean follow-up time was 28.9 months. Eight cases (20.5%) underwent surgical treatment; surgical bypasses and endovascular interventions. Only one patient had subsequential ischemic symptom at immediate postoperative vascular bypass surgery. The remaining patients had no report of progressive or recurrent neurological deficit symptom. CONCLUSION: Poor CVR response is more often found in higher degree of steno-occlusion. Even inconclusive predicting incidence of recurrent ischemic stroke, CVR that reflects the capacity of neuro-autoregulation.

2.
J Med Assoc Thai ; 99(5): 629-35, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27501622

RESUMO

OBJECTIVE: The study is aimed to develop and assess the quality of an evaluation form used to evaluate the nurse anesthetic trainees' skills in undertaking a pre-use check of an anesthetic machine. MATERIAL AND METHOD: An evaluation form comprising 25 items was developed, informed by the guidelines published by national anesthesiologist societies and refined to reflect the anesthetic machine used in our institution. The item-checking included the cylinder supplies and medical gas pipelines, vaporizer back bar, ventilator anesthetic breathing system, scavenging system and emergency back-up equipment. The authors sought the opinions of five experienced anesthetic trainers to judge the validity of the content. The authors measured its inter-rater reliability when used by two achievement scores evaluating the performance of 36 nurse anesthetic trainees undertaking 15-minute anesthetic machine checks and test-retest the reliability correlation scores between the two performances in the seven days interval. RESULTS: The five experienced anesthesiologists agreed that the evaluation form accurately reflected the objectives of anesthetic machine checking, equating to an index of congruency of 1.00. The inter-rater reliability of the independent assessors scoring was 0.977 (p = 0.01) and the test-retest reliability was 0.883 (p = 0.01). CONCLUSION: An evaluation form proved to be a reliable and effective tool for assessing the anesthetic nurse trainees' checking of an anesthetic machine before the use. This evaluation form was brief clear and practical to use, and should help to improve anesthetic nurse education and the patient safety.


Assuntos
Anestesiologia/educação , Anestesiologia/instrumentação , Educação em Enfermagem , Competência Clínica , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudantes de Enfermagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...