Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
Angew Chem Int Ed Engl ; 61(36): e202205720, 2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-35561144

RESUMO

Enantioselective reactions are at the core of chemical synthesis. Their development mostly relies on prior knowledge, laborious product analysis and post-rationalization by theoretical methods. Here, we introduce a simple and fast method to determine enantioselectivities based on mass spectrometry. The method is based on ion mobility separation of diastereomeric intermediates, formed from a chiral catalyst and prochiral reactants, and delayed reactant labeling experiments to link the mass spectra with the reaction kinetics in solution. The data provide rate constants along the reaction paths for the individual diastereomeric intermediates, revealing the origins of enantioselectivity. Using the derived kinetics, the enantioselectivity of the overall reaction can be predicted. Hence, this method can offer a rapid discovery and optimization of enantioselective reactions in the future. We illustrate the method for the addition of cyclopentadiene (CP) to an α,ß-unsaturated aldehyde catalyzed by a diarylprolinol silyl ether.


Assuntos
Aldeídos , Éteres , Aldeídos/química , Catálise , Éteres/química , Espectrometria de Massas , Estereoisomerismo
3.
Chinese Journal of Cardiology ; (12): 563-569, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-940889

RESUMO

Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.


Assuntos
Humanos , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
Chinese Journal of Cardiology ; (12): 461-466, 2021.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-941302

RESUMO

Objective: To investigate the safety and efficacy of left ventricular guidewire pacing during transcatheter aortic valve replacement (TAVR). Methods: This is a retrospective study. Thirteen patients, who underwent TAVR with left ventricular guidewire pacing from October 2019 to December 2019 in Fuwai Hospital, were included. Clinical data and operational procedure data of the patients were collected. Changes in blood pressure and electrocardiogram were observed during operations. Ascending aorta angiography was performed to evaluate the regurgitation of aortic valve after valve implantion. The incidence of major adverse cardiac events during hospitalization and at 3-months after discharge was recorded. Results: There were 7 male and 6 female patients in this cohort,and age was (73.8±8.3) years old. Among the 13 patients, 9 were tricuspid aortic valves, 3 were bicuspid aortic valves, and 1 was degenerated bioprosthetic surgical aortic valve. TAVR were successfully performed in all of the 13 cases using pacing through the left ventricular guidewire. During balloon dilation, the blood pressure decreased to below 60 mmHg (1 mmHg=0.133 kPa) after 180 beats/min pacing, and the valve release process was smooth and the position was stable. The results of aortography showed that there was no regurgitation in 7 cases, mild regurgitation in 5 cases and moderate regurgitation in 1 case. Three patients required temporary pacing during the procedure due to complete heart block, among whom 1 patient was implanted with permanent pacemaker during hospitalization, and the other 2 patients recovered within 24 hours after operation. In another case, there was no significant change of electrocardiogram during the operation, and complete heart block occurred 10 days after the operation, and treated with permanent pacemaker. The other 10 patients began to carry out bedside activities and rehabilitation training 24 hours after operation. There was no death, myocardial infarction, stroke and other major adverse cardiac events during hospitalization and at 3-month follow-up after discharge. Conclusion: Left ventricular guidewire pacing is a safe and effective strategy for TAVR.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
5.
Chinese Journal of Cardiology ; (12): 66-70, 2021.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-941236

RESUMO

Objective: To explore the feasibility of the single-stage stent implantation following rotational atherectomy combined with transcatheter aortic valve replacement (TAVR) in treating patients with severe aortic stenosis(AS) and severe calcified coronary artery stenosis. Methods: Three patients who received single-stage stent implantation following rotational atherectomy combined with TAVR in Fuwai hospital from April to October 2019 were included in this retrospective analysis. Clinical and anatomical features (including echocardiography and aortic CT) of the patients were collected, efficacy and safety of this operation strategy were observed and 6 months follow up results were summarized. Results: Three patients (2 females, 66-80 years old) were included. The mean Society of Thoracic Surgeons (STS) risk score was 7.8%. The mean maximum velocity of aortic valve was 4.4 m/s, the mean transvalvular pressure gradient was 53.2 mmHg (1 mmHg=0.133 kPa), mean left ventricular ejection fraction (LVEF) was 48.6%. All three patients had severe calcified coronary artery stenosis: left anterior descending artery (LAD, n=2) and left main coronary artery (LM, n=1), requiring rotary grinding. The mean SYNTAX score was 20. All the procedures were performed through transfemoral access. After aortic valve crossing, all coronary lesions were successfully treated with stent implantation following rotational atherectomy, transfemoral TAVR was then immediately performed with a self-expandable Venus-A valve. One patient underwent"valve-in-valve"implantation due to the high-implantation position of the first valve. The procedures were completed without complications in all the three patients. The immediate effect was satisfactory. Echocardiography results showed that the mean maximum velocity of aortic valve was 2.1 m/s, mean gradient was 9.3 mmHg, and mean LVEF was 59% after the procedure. There was no death and revascularization during the 6 months follow-up. Conclusion: In patients with severe calcified coronary artery and severe AS with high risk of cardiac surgery, the single-stage stent implantation following rotational atherectomy combined with TAVR is feasible and results are satisfactory in this patient cohort.

6.
PeerJ ; 6: e5111, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29942714

RESUMO

BACKGROUND: Aflatoxin B1 (AFB1), deoxynivalenol (DON), HT-2, ochratoxin A (OTA), zearalenone (ZEA) are the most common mycotoxins that are found in corn-based animal feed which have multiple toxic effects on animals and humans. Previous studies reported that these mycotoxins impaired mammalian oocyte quality. However, the effective concentrations of mycotoxins to animal oocytes were different. METHODS: In this study we aimed to compare the sensitivity of mouse and porcine oocytes to AFB1, DON, HT-2, OTA, and ZEA for mycotoxin research. We adopted the polar body extrusion rate of mouse and porcine oocyte as the standard for the effects of mycotoxins on oocyte maturation. RESULTS AND DISCUSSION: Our results showed that 10 µM AFB1 and 1 µM DON significantly affected porcine oocyte maturation compared with 50 µM AFB1 and 2 µM DON on mouse oocytes. However, 10 nM HT-2 significantly affected mouse oocyte maturation compared with 50 nM HT-2 on porcine oocytes. Moreover, 5 µM OTA and 10 µM ZEA significantly affected porcine oocyte maturation compared with 300 µM OTA and 50 µM ZEA on mouse oocytes. In summary, our results showed that porcine oocytes were more sensitive to AFB1, DON, OTA, and ZEA than mouse oocytes except HT-2 toxin.

7.
Toxins (Basel) ; 10(3)2018 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-29518909

RESUMO

The objective of this study was to investigate the individual and combined contamination of aflatoxin B1 (AFB1), zearalenone (ZEN) and deoxynivalenol (DON) in feedstuffs from different Provinces of China between 2016 and 2017. A total of 1569 samples, including 742 feed ingredients and 827 complete pig feed samples, were collected from various regions of China for mycotoxins analysis. The results showed that individual occurrence rates of AFB1, ZEN, and DON were more than 83.3%, 88%, and 74.5%, respectively, in all the tested samples. DON was the most prevalent contaminant, followed by ZEN and AFB1, with the average concentrations ranging from 450.0-4381.5 µg/kg, 2.3-729.2 µg/kg, and 1.3-10.0 µg/kg, respectively. Notable, 38.2%, 10.8%, and 0.6% of complete pig feeds were contaminated with DON, ZEN, and AFB1 over China's regulatory limits, respectively. Moreover, over 75.0% analyzed samples were co-contaminated with two or three mycotoxins. In conclusion, the current study revealed that the feedstuffs in China were severely contaminated with DON, followed by ZEN and AFB1 during the past two years. These findings highlight the importance of monitoring mycotoxins in livestock feed and implementing feed management and bioremediation strategies to reduce mycotoxin exposure.


Assuntos
Aflatoxina B1/análise , Ração Animal/análise , Contaminação de Alimentos/análise , Tricotecenos/análise , Zearalenona/análise , China , Monitoramento Ambiental
8.
Chinese Journal of Biotechnology ; (12): 973-982, 2018.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-687719

RESUMO

The objectiue was to explore how to improve stem cell derivation from human great saphenous vein. After the saphenous vein was cut into small pieces, the cells of the vessel wall were obtained by tissue adherent method and digestion with type Ⅱ collagenase. The morphological changes of blood vessel wall were observed under inverted microscope. The survival of vascular wall cells was assessed by trypan blue staining. Stem cells doubly positive for CD34 and CD117 were sorted out by immunofluorescent staining and flow cytometry. The cells obtained by tissue adherence method exhibited signs of fibrotic changes and aging at the third passage (P3), while the cells extracted by enzymatic digestion still showed colony-like growth. Survival rates of these two groups of cells were (91.7±1.2)% and (97.2±0.7)%, (P=0.005). The results of flow cytometry showed that the positive rates of CD34 and CD117 double positive cells in these two groups were (0.16± 0.05)% and (0.44±0.07)%, respectively, with statistical significance (P=0.005). Immunofluorescent staining showed that the positive rates of double positive stem cells in the two groups were (89.41±2.06)% and (94.03±1.83)%, P<0.05 one week after the sorted stem cells were cultured. The positive rates of CD31, VEGF2 and SMA in the stem cells determined by flow cytometry were (0.12±0.01)%, (0.19±0.02)% and (0.45±0.01)%, respectively, which were not statistically different from those of the control groups. This could rule out substantial inclusion of mature endothelial cells and smooth muscle cells. Tube forming experiment confirmed that these vascular stem cells had developmental plasticity. More viable and morphologically healthy vascular stem cells can be derived by enzymatic digestion. These cells can be widely used in clinical and basic research.

9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-698690

RESUMO

BACKGROUND:In general, a single-type artificial bone is difficult to meet the requirements for bone defect repair and extracellular matrix of bone tissue engineering. Compositing and processing the materials with different properties can form the composite-type artificial bone, which can either ensure the biological activity or effectively improve its mechanical properties.OBJECTIVE: To summarize the present situation of the application of composite-type artificial bone and prospects the development trend. METHODS:The literatures were retrieved from CNKI, ScienceDirect, PubMed, SpingerLink, El Village, Wiley databases from January 2000 to April 2017. The key words were "composite scaffold, tissue engineering, artificial bone" in Chinese and English, respectively. The selected literatures were analyzed according to the inclusion and exclusion criteria. RESULTS AND CONCLUSION: The requirements for the scaffolds used for bone tissue engineering are complex and it should carefully consider and control various factors used in the design and preparation of scaffolds, including microporous structure, mechanical strength, degradation rate, porosity, growth factor, morphology and surface chemistry, so as to meet the bone tissue engineering applications. The preparation of tissue-engineered bone scaffold is based on biological active substances and matrix materials through a reasonable manner. It simulates the components of natural bone matrix, promotes the adhesion, proliferation and differentiation of bioactive substances, and gives play to its functions of osteogenesis. Although existing techniques and methods have made significant progress in the preparation of composite scaffolds, there is no technique or method to fully meet all the requirements for preparation of tissue-engineered bone scaffold.

10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-508231

RESUMO

BACKGROUND:The application of virtual reality technology in preoperative simulation can reduce the risk in operation effectively and improve the quality of surgery. Virtual reality technology has very important practical significance in the application of surgery. OBJECTIVE:The reverse engineering and virtual reality technology were used to achieve the preoperative simulation of a case of Pilon fracture. METHODS:The affected bones were reconstructed according to the CT data using the patient’s ankle portion in MIMICS software, and the separated bone fractures were restored. According to the characteristics of virtual reality technology, further processing on bone model was carried out using Geomagic software;the models of the fractured bones were exported with STL format. The restored bone fragments were checked up to determine integrity in the virtual reality operation platform. These models were used to do simulated operations in the virtual reality operation platform. RESULTS AND CONCLUSION:A case of Pilon fracture was simulated by using reverse engineering and virtual reality technology preoperatively. The processed 3D model was introduced into the virtual reality system to simulate the operation and help doctors choose the type, position and direction of the surgical approach and plate;the effect is good.

11.
Journal of Medical Biomechanics ; (6): E249-E255, 2015.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-804475

RESUMO

Objective To analyze the influence of microporous parameters on mechanical behavior of bone tissue engineered-scaffolds, and provide references for optimizing the microporous structure design. Methods The finite element models of scaffolds with microporous structures were established by using ANYSYS software. The relationships between porosity and maximum equivalent stress as well as maximum total deformation were calculated. The effects of microporous spacing and diameter on maximum equivalent stress, maximum total deformation and internal strain were compared and analyzed. Results The influence rule of microporous spacing in x and y direction was consistent. With the increase of microporous spacing from 0.6 mm to 2.0 mm, the maximum equivalent stress reduced from 63.1 MPa to 46.3 MPa, the maximum total deformation reduced from 23.8 μm to 21.8 μm, and the proportion of the best strain range increased from 80% to 84%. However, with the increase of microporous spacing in z direction, the maximum equivalent stress increased from 38.3 MPa to 47.8 MPa, the maximum total deformation increased from 20. 8 μm to 22.8 μm, and the proportion of the best strain range fluctuated within the range of 82%-85%. With the increase of microporous diameter in x and y direction from 0.1 mm to 1.0 mm, the maximum equivalent stress increased from 32.4 MPa to 78.4 MPa, the maximum total deformation increased from 19.9 μm to 38.2 μm, and the proportion of the best strain range reduced from 90% to 53%. With the increase of microporous diameter in z direction, the maximum equivalent stress reduced from 58.8 MPa to 37.9 MPa, the maximum total deformation increased from 23.3 μm to 25.9 μm, and the proportion of the best strain range increased from 82% to 87%. Conclusions The greater the porosity and the proportion of the best strain range, the smaller maximum equivalent stress and maximum total deformation would be, the scaffolds would have the better biological and mechanical properties. These results have reference values for design and optimization of scaffold structure.

12.
China Medical Equipment ; (12): 82-84, 2014.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-456646

RESUMO

Distal tibial fractures (Distal tibial fracture) is a common clinical fractures type, more for high-energy damage, fracture type is more complicated. Because of the distal tibia special anatomic structure (soft tissue is less, less blood supply), if the operation method is not suitable or fixed equipment selection is not reasonable, because fracture healing, osteomyelitis, also can damage the function of the ankle joint. Treatment shall be based on the fracture position, type, in the process of the polluted situation and surrounding soft tissue trauma injury and so on many factors that determine the way and the internal fixation methods. This paper reviews recent year different types of distal tibial fracture fixation and fixed ways of literature research, in the treatment of distal tibial fracture clinical practice to provide the reference of objective reasonably select fixation and evaluation standard.

13.
Chinese Journal of Cardiology ; (12): 577-582, 2013.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-261493

RESUMO

<p><b>OBJECTIVE</b>To evaluate the safety and feasibility of carotid artery stenting (CAS) for treating patients with coexisting carotid and coronary artery disease.</p><p><b>METHODS</b>The clinical data of 237 consecutive patients [(66.1 ± 7.7) years old, 79.7% male] with coexisting carotid and coronary artery disease undergoing CAS in Fuwai hospital from January 2005 to June 2010. The patients were analyzed retrospectively.Indication for CAS was defined as carotid artery diameter reduction of > 60% (symptomatic) or > 80% (asymptomatic) with suitable carotid artery anatomy for stenting. Thirty-day rates of stroke, death and myocardial infarction after CAS were assessed.</p><p><b>RESULTS</b>All patients suffered from coronary artery disease, of whom 87(36.7%) had unstable angina pectoris and 82(34.6%) had recent myocardial infarction (< 30 days). The procedural success rate of CAS was 99.2 % (235/237). Cerebral protection devices were used in 234 patients (99.6%). Among them, 36(15.2%) patients received simultaneous bilateral CAS and 79(33.3%) patients underwent simultaneous percutaneous intervention of other non-coronary arteries.Within 30 days after CAS, 127(53.6%) patients underwent coronary revascularization, including 118(49.6%) coronary artery bypass grafting and 9 (3.8%) percutaneous coronary intervention. The rate of major stroke, minor stroke, death and myocardial infarction from time of CAS to 30 days was 2.1% (5/237), 3.0% (7/237),0.4% (1/237) and 0.4% (1/237) respectively.</p><p><b>CONCLUSION</b>Data from this study indicate that CAS is safe and feasible for treating patients with coexisting carotid and coronary artery disease with a low incidence of periprocedural complication rate.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artérias Carótidas , Estenose das Carótidas , Terapêutica , Doença da Artéria Coronariana , Seguimentos , Estudos Retrospectivos , Stents
14.
Chinese Journal of Cardiology ; (12): 278-282, 2012.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-275059

RESUMO

<p><b>OBJECTIVE</b>To evaluate the safety and feasibility of simultaneous bilateral carotid stenting for treating patients with bilateral atherosclerotic carotid stenosis.</p><p><b>METHODS</b>The clinical data of 39 consecutive patients with bilateral atherosclerotic carotid stenosis undergoing simultaneous bilateral carotid artery stenting in Fuwai hospital from January 2005 to December 2009 were collected and analyzed retrospectively. The reduction of the angiographic diameter stenosis after stenting and clinical outcomes of 30 days after stenting including hyperperfusion syndrome, hemodynamic depression, stroke, myocardial infarction and death were assessed.</p><p><b>RESULTS</b>The patients were 43 - 78 (65.9 ± 8.5) years old, and there were 25 (64.1%) male. Carotid stenting procedure success rate was 100%. Distal embolic protection devices were used in all patients, and 20 (51.3%) out of 39 patients underwent coronary artery bypass surgery after carotid stenting. The angiographic diameter stenosis reduced from (87.0 ± 5.8)% to (10.2 ± 5.6)% after stenting (P < 0.01). Up to 30 days after carotid artery stenting, the incidence of hyperperfusion syndrome, hemodynamic depression, minor stroke, major stroke, myocardial infarction and death was 2.6% (1/39), 28.2% (11/39), 5.1% (2/29), 0, 2.6% (1/39), 2.6% (1/39), respectively.</p><p><b>CONCLUSION</b>The data show that simultaneous bilateral carotid stenting is a technically feasible and safe alternative for patients with severe bilateral atherosclerotic carotid stenosis.</p>


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão , Artérias Carótidas , Estenose das Carótidas , Cirurgia Geral , Estudos Retrospectivos , Stents , Resultado do Tratamento
15.
Chinese Medical Journal ; (24): 4221-4225, 2012.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-339867

RESUMO

<p><b>BACKGROUND</b>Among patients with advanced multivessel coronary disease, left ventricular (LV) function is widely variable, and clinical and angiographic correlates of ventricular dysfunction remain to be defined.</p><p><b>METHODS</b>Among 73 339 patients undergoing diagnostic cardiac catheterization at a single center in China, patients with left ventriculographic assessment were identified with three-vessel coronary disease with or without left main involvement. Clinical and angiographic characteristics were examined among patients with normal or varying extent of LV dysfunction, and predictors of LV impairment (ejection fraction (EF): < 25%, 25% - 40% or > 40%) were determined.</p><p><b>RESULTS</b>Among 11 950 patients identified with three-vessel coronary disease, the sample distribution of LVEF was > 40%, n = 10 776; 25% - 40%, n = 948; < 25%, n = 226. Patients with reduced LV function (< 40%) more commonly were male and had a history of myocardial infarction (MI), diabetes or unstable angina. Hypertension was more frequent in those with LVEF ≥ 40%. In a multivariate Logistic regression analysis, prior MI (odds ratio (OR), 3.37; 95% confidence interval (CI), 2.96 - 3.84) was most predictive of LVEF < 40%, followed by male gender, diabetes, and presentation with unstable angina. For LVEF < 25%, only prior MI was identified as a significant correlate of severe LV dysfunction (OR 4.06, 95%CI 3.06 - 5.39). Following exclusion of patients with previous MI (n = 7416), male gender and diabetes were predictive of LVEF < 40%, yet presentation with unstable angina was the only factor significantly associated with LVEF < 25%.</p><p><b>CONCLUSION</b>Among individuals identified with three-vessel coronary disease with or without left main involvement, previous MI was the most significant risk factor of LV dysfunction.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Coronária , Doença das Coronárias , Patologia , Disfunção Ventricular Esquerda , Patologia
16.
Chinese Journal of Cardiology ; (12): 238-241, 2011.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-272270

RESUMO

<p><b>OBJECTIVE</b>In this study we investigated the functional restoration of nonsense mutations in the SCN5A gene.</p><p><b>METHODS</b>The readthrough-enhancing reagents were introduced to HEK293 cells to suppress one nonsense mutation W822X in the SCN5A gene. Patch-clamp was used to record the whole-cell current and dynamics. Western blot and immunofluorescence staining were used to certify the expression and the location of the sodium channel.</p><p><b>RESULTS</b>In transfected HEK293 cells, the nonsense mutation in SCN5A inhibited the expression level of full-length protein, and the sodium currents from the mutant channels were less than 3% of the wild-type level. Readthrough enhancement by decreasing translation termination efficiency with a siRNA targeting eukaryotic release factor eRF3a (a GTPase that binds eRF1), the sodium current from the mutant cDNAs was restored to as much as 30% of the wild-type. After the treatment by the readthrough-enhancing reagents, the channels from cDNA carrying W822X remained the features of wild-type phenotype, and Western blot and immunochemical staining also showed the expression of full-length channel proteins.</p><p><b>CONCLUSION</b>Readthrough-enhancing reagents could effectively suppress nonsense mutations in SCN5A and partially restore the function of sodium channel and the expression of full-length channels.</p>


Assuntos
Humanos , Códon sem Sentido , Células HEK293 , Técnicas de Patch-Clamp , Plasmídeos , RNA Interferente Pequeno , Canais de Sódio , Genética , Metabolismo , Transfecção
17.
Lab Chip ; 8(6): 885-91, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18497907

RESUMO

Sarin (C(4)H(10)FO(2)P,O-isopropyl methylphosphonofluoridate) is a colourless, odourless and highly toxic phosphonate that acts as a cholinesterase inhibitor and disrupts neuromuscular transmission. Sarin and related phosphonates are chemical warfare agents, and there is a possibility of their application in a military or terrorist attack. This paper reports a lab-on-a-chip device for detecting a trace amount of sarin in a small volume of blood. The device should allow early detection of sarin exposure during medical triage to differentiate between those requiring medical treatment from mass psychogenic illness cases. The device is based on continuous-flow microfluidics with sequential stages for lysis of whole blood, regeneration of free nerve agent from its complex with blood cholinesterase, protein precipitation, filtration, enzyme-assisted reaction and optical detection. Whole blood was first mixed with a nerve gas regeneration agent, followed by a protein precipitation step. Subsequently, the lysed product was filtered on the chip in two steps to remove particulates and fluoride ions. The filtered blood sample was then tested for trace levels of regenerated sarin using immobilised cholinesterase on the chip. Activity of immobilised cholinesterase was monitored by the enzyme-assisted reaction of a substrate and reaction of the end-product with a chromophore. Resultant changes in chromophore-induced absorbance were recorded on the chip using a Z-shaped optical window. Loss of enzyme activity obtained prior and after passage of the treated blood sample, as shown by a decrease in recorded absorbance values, indicates the presence of either free or regenerated sarin in the blood sample. The device was fabricated in PMMA (polymethylmethacrylate) using CO(2)-laser micromachining. This paper reports the testing results of the different stages, as well as the whole device with all stages in the required assay sequence. The results demonstrate the potential use of a field-deployable hand-held device for point-of-care triage of suspected nerve agent casualties.


Assuntos
Técnicas Biossensoriais/métodos , Substâncias para a Guerra Química/análise , Inibidores da Colinesterase/sangue , Procedimentos Analíticos em Microchip/métodos , Sarina/sangue , Técnicas Biossensoriais/instrumentação , Precipitação Química , Colinesterases/química , Colinesterases/metabolismo , Enzimas/química , Enzimas/metabolismo , Filtração , Humanos , Dispositivos Lab-On-A-Chip , Óptica e Fotônica , Proteínas/química , Proteínas/metabolismo , Fatores de Tempo
18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-401528

RESUMO

Normal cells have limited proliferation ability.After certain cycles of proliferation,they will lose the response ability to growth factors and finally cease division and start the course of aging. In current opinion,lacking of the terminal end of a chromosome(telomere)is the cause for cells to loss the proliferation ability and leads cells to aging and death.The human telomerase catalytic subunit 1(hTERT)can activate telomemse which prolong DNAs of the terminal end of chmmosome and help cells gain genomic stabilization.The discoveries of telomere,telomerase and hTERT provide new idea for studying of cell aging and the findings are also applied in the establishment of immortal cell line. Also they may play an important role in the studv of biological feature of seed cell in tissue engineering and the establishment of cell bank.

19.
Chinese Journal of Cardiology ; (12): 313-316, 2008.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-243786

RESUMO

<p><b>OBJECTIVE</b>To explore the disease-causing gene mutation in Chinese families with hypertrophic cardiomyopathy (HCM) and to analyze the correlation between the genotype and phenotype.</p><p><b>METHODS</b>Samples of peripheral blood were collected from three Chinese families with HCM (at least two HCM patients existed/family). The exons in the functional regions of the beta myosin heavy chain gene (MYH7) were amplified with PCR and the products were sequenced.</p><p><b>RESULTS</b>A Val606Met missen mutation was identified in the exon 16 of MYH7 gene in a Chinese family and this mutation was identified in all HCM patients (n = 4) and there was also a 15-years-old young mutation carrier who was not HCM patient now (penetrance of 80%). This mutation was not identified in other healthy family members in this family, in other 2 Chinese familiar HCM families and in 120 non-HCM control patients.</p><p><b>CONCLUSION</b>The Val606Met missen mutation is closely associated with familiar HCM in a Chinese family which is associated with clinical phenotype with a penetrance of 80%.</p>


Assuntos
Adolescente , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sequência de Bases , Miosinas Cardíacas , Genética , Cardiomiopatia Hipertrófica Familiar , Genética , Éxons , Genótipo , Mutação de Sentido Incorreto , Cadeias Pesadas de Miosina , Genética , Linhagem
20.
Chinese Medical Journal ; (24): 150-154, 2007.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-273319

RESUMO

<p><b>BACKGROUND</b>Atrial fibrillation is a common arrhythmia with multi-factorial pathogenesis. Recently, a single nucleotide polymorphism (G/T) at position 1057 in the KCNE4 gene, resulting in a glutamic acid (Glu, E)/aspartic acid (Asp, D) substitution at position 145 of the KCNE4 peptide, was found in our laboratory to be associated with idiopathic atrial fibrillation (atrial fibrillation more frequent with KCNE4 145D). However, the functional effect of the KCNE4 145E/D polymorphism is still unknown.</p><p><b>METHODS</b>We constructed KCNE4 (145E/D) expression plasmids and transiently co-transfected them with the KCNQ1 gene into Chinese hamster ovary-K1 cells and performed whole-cell patch-clamping recording to identify the possible functional consequences of the single nucleotide polymorphism. Quantitative data were analyzed by Student;s t test. Probability values less than 0.05 were considered statistically significant.</p><p><b>RESULTS</b>A slowly activating, non-inactivating voltage-dependent current ((24.0 +/- 2.9) pA/pF, at +60 mV)) could be recorded in the cells transfected with KCNQ1 alone. Co-expression of wild type KCNE4 inhibited the KCNQ1 current ((7.3 +/- 1.1) pA/pF)). By contrast, co-expression of KCNE4 (145D) augment the KCNQ1 current ((42.9 +/- 7) pA/pF)). The V(1/2) of activation for the KCNQ1/KCNE4 (145D) current was shifted significantly towards the depolarizing potential compared to that for the KCNQ1 current ((-2.3 +/- 0.2) mv vs (-13.0 +/- 1.5) mv, P < 0.01)) without changing the slope factorkappa. Furthermore, KCNE4 (145D) also affected the activation and deactivation kinetics of KCNQ1 channels.</p><p><b>CONCLUSION</b>We provide experimental evidence that the KCNE4 (145E/D) polymorphism exerts the effect of "gain of function" on the KCNQ1 channel. It may underlie the genetic mechanism of atrial fibrillation. Further studies on the functional association between I(Ks) and KCNE4 (145D) polymorphism in cardiac myocytes are suggested.</p>


Assuntos
Animais , Cricetinae , Humanos , Células CHO , Cricetulus , Canal de Potássio KCNQ1 , Fisiologia , Polimorfismo de Nucleotídeo Único , Canais de Potássio de Abertura Dependente da Tensão da Membrana , Genética , Fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...