Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Knee Surg ; 36(8): 814-819, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35181873

RESUMO

Robotic-assisted total knee arthroplasty (RA-TKA) has demonstrated improved alignment and outcome scores when compared with manual total knee arthroplasty (M-TKA); however, few studies compare differences in the same patient. This study is a retrospective review that assesses clinical outcomes of 36 patients who underwent a primary RA-TKA and had undergone a prior contralateral M-TKA. All surgeries were performed by a single surgeon at the same institution. Patients were assessed for differences in hospital length of stay, improvement in pre- versus postoperative range of motion, Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores. Student's t-test and Fisher's exact test were utilized to detect significant differences. Patient demographics showed a mean age of 64.5, 24 females (67%), and mean body mass index of 35.1 ± 5.7. The average follow-up time was 2.9 years for M-TKA and 1.3 years for RA-TKA. Hospital length of stay was decreased by 5.5 hours for RA-TKA (p = 0.03). Total postoperative WOMAC score was not statistically different between RA-TKA and M-TKA (p = 0.061); however, pain and stiffness components were statistically improved in RA-TKA (p = 0.041 and p = 0.007), respectively. KOOS was higher in RA-TKA, which approached statistical significance (p = 0.005). Pre- versus postoperative knee flexion improved significantly in both cohorts. There was a significant difference in pre- versus postoperative range of motion at 3, 6, and 12 months follow-up after RA-TKA in comparison to M-TKA (p < 0.05). There were no postoperative complications. Patients who underwent RA-TKA demonstrated early improvement at 1-year follow-up in pain, stiffness, and knee flexion when compared with their prior contralateral M-TKA. There was a significant decrease in postoperative length of stay by 5.5 hours in the RA-TKA group. Limitations include a small sample size and differences in follow-up times between RA-TKA and M-TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Feminino , Humanos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento , Dor/etiologia
2.
J Arthroplasty ; 37(12): 2406-2411, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35738363

RESUMO

BACKGROUND: Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS: We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS: The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION: These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Polietileno , Cobalto , Cromo , Corrosão , Metais , Medição de Risco , Dor/etiologia
3.
Trauma Case Rep ; 38: 100614, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35146108

RESUMO

Three-part proximal humerus fractures in the elderly continue to be difficult to surgically treat. We evaluated the Hawkins wiring (HW) technique, which utilizes figure-of-eight tension band wiring, to treat three-part proximal humerus fractures involving the greater tuberosity. Currently, there is a paucity of data detailing patient outcomes and radiographic follow-up of this technique. The purpose of this case series is to evaluate patient reported outcomes and radiographic follow-up for fractures treated with this technique. Over two years, six patients at our institution underwent HW to treat three-part proximal humerus fractures. Average DASH and Oxford Shoulder scores (OSS) were 20.4 (range, 1-40) and 40 (range, 33-46) respectively. All patients had satisfactory return of function after surgery. Radiographic union was achieved in all six patients and there were no reported complications. HW technique is an efficacious treatment for three-part proximal humerus fractures in elderly patients.

4.
JBJS Case Connect ; 11(2)2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34111035

RESUMO

CASE: Acrometastasis is extremely rare, accounting for 0.1% of all skeletal metastases. Metastases to the carpus are rarer still. This condition can be the first manifestation of an occult malignancy and generally indicates advanced disease. We present the case of a 53-year-old woman with acrometastasis of squamous cell lung cancer to the trapezium as the initial presentation of her malignancy. CONCLUSION: The presentation of acrometastasis can mimic infectious or inflammatory processes, leading to an erroneous diagnosis. Although exceptionally uncommon, it is important to consider as a differential diagnosis for a destructive hand lesion.


Assuntos
Carcinoma de Células Escamosas , Neoplasias Pulmonares , Trapézio , Carcinoma de Células Escamosas/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...