Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 10(3)2017 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-28772624

RESUMO

The steel frame reinforced with steel shear wall is a lateral load resisting system and has higher strength and shear performance than the concrete shear wall system. Especially, using corrugated steel plates in these shear wall systems improves out-of-plane stiffness and flexibility in the deformation along the corrugation. In this paper, a cyclic loading test of this steel frame reinforced with trapezoidal-corrugated steel plate was performed to evaluate the structural performance. The hysteresis behavior and the energy dissipation capacity of the steel frame were also compared according to the corrugated direction of the plate. For the test, one simple frame model without the wall and two frame models reinforced with the plate are considered and designed. The test results showed that the model reinforced with the corrugated steel plate had a greater accumulated energy dissipation capacity than the experimental result of the non-reinforced model. Furthermore, the energy dissipation curves of two reinforced frame models, which have different corrugated directions, produced similar results.

2.
Forensic Sci Int ; 248: 154-71, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25637956

RESUMO

This paper presents a statistical model for the quantification of the weight of fingerprint evidence. Contrarily to previous models (generative and score-based models), our model proposes to estimate the probability distributions of spatial relationships, directions and types of minutiae observed on fingerprints for any given fingermark. Our model is relying on an AFIS algorithm provided by 3M Cogent and on a dataset of more than 4,000,000 fingerprints to represent a sample from a relevant population of potential sources. The performance of our model was tested using several hundreds of minutiae configurations observed on a set of 565 fingermarks. In particular, the effects of various sub-populations of fingers (i.e., finger number, finger general pattern) on the expected evidential value of our test configurations were investigated. The performance of our model indicates that the spatial relationship between minutiae carries more evidential weight than their type or direction. Our results also indicate that the AFIS component of our model directly enables us to assign weight to fingerprint evidence without the need for the additional layer of complex statistical modeling involved by the estimation of the probability distributions of fingerprint features. In fact, it seems that the AFIS component is more sensitive to the sub-population effects than the other components of the model. Overall, the data generated during this research project contributes to support the idea that fingerprint evidence is a valuable forensic tool for the identification of individuals.


Assuntos
Dermatoglifia , Modelos Estatísticos , Análise Espacial , Humanos , Funções Verossimilhança
3.
Biochemistry ; 52(48): 8652-62, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24175947

RESUMO

The cocaine-binding aptamer is unusual in that it tightly binds molecules other than the ligand it was selected for. Here, we study the interaction of the cocaine-binding aptamer with one of these off-target ligands, quinine. Isothermal titration calorimetry was used to quantify the quinine-binding affinity and thermodynamics of a set of sequence variants of the cocaine-binding aptamer. We find that the affinity of the cocaine-binding aptamer for quinine is 30-40 times stronger than it is for cocaine. Competitive-binding studies demonstrate that both quinine and cocaine bind at the same site on the aptamer. The ligand-induced structural-switching binding mechanism of an aptamer variant that contains three base pairs in stem 1 is retained with quinine as a ligand. The short stem 1 aptamer is unfolded or loosely folded in the free form and becomes folded when bound to quinine. This folding is confirmed by NMR spectroscopy and by the short stem 1 construct having a more negative change in heat capacity of quinine binding than is seen when stem 1 has six base pairs. Small-angle X-ray scattering (SAXS) studies of the free aptamer and both the quinine- and the cocaine-bound forms show that, for the long stem 1 aptamers, the three forms display similar hydrodynamic properties, and the ab initio shape reconstruction structures are very similar. For the short stem 1 aptamer there is a greater variation among the SAXS-derived ab initio shape reconstruction structures, consistent with the changes expected with its structural-switching binding mechanism.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , Cocaína/metabolismo , Quinina/metabolismo , Aptâmeros de Nucleotídeos/química , Sequência de Bases , Sítios de Ligação , Ligação Competitiva , Cocaína/química , Hidrodinâmica , Ligantes , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Concentração Osmolar , Quinina/química , Especificidade por Substrato , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...