Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Leg Med (Tokyo) ; 54: 101993, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34808562

RESUMO

Based on the screening results of mass analyses using gas chromatography- mass spectrometry (GC-MS) and liquid chromatograph-tandem mass spectrometry (LC-MS/MS), we assessed the performance of Status DS10 (Status) and DRIVEN-FLOW® M8-Z (DF8), and compared the results with those of Triage DOA® (Triage) using 356 autopsy urine samples within one month of death. The sensitivity to benzodiazepines was 0.52 in Triage, 0.59 in Status, and 0.58 in DF8 with few false-positive cases. Triage detected triazolo-derivatives more easily than DF8. DF8 detected diazepam and nitro-benzodiazepines more easily than Status and Triage, with Status performing better than Triage. However, lorazepam detection with Status was difficult. There were 11 false-positive cases for amphetamines in Triage and 12 for Status-AMP at more than one week after death, but there were no false-positive in Status-MET and DF8. Tricyclic antidepressant (TCA) was detected in five cases by mass analysis, while there were 6 false-positive cases in Triage and 10 in both Status and DF8. In the TCA false-positive cases, tricyclic psychotics such as quetiapine, chlorpromazine, and carbamazepine existed. There were 23 true-positive and 6 false-positive cases for zolpidem in DF8 without false-negative cases. The accuracy of Status and DF8 for barbiturates or opiates was almost 1, but Triage was 0.98. There were no samples containing cocaine, THC, phencyclidine, or methadone. Based on the above, we conclude that Status and DF8 are comparable or slightly better than Triage, with fewer false-positive and fewer false-negative cases, except for TCA.


Assuntos
Detecção do Abuso de Substâncias , Triagem , Autopsia , Cromatografia Líquida , Avaliação Pré-Clínica de Medicamentos , Humanos , Imunoensaio , Espectrometria de Massas em Tandem
2.
Leg Med (Tokyo) ; 48: 101804, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33152676

RESUMO

The efficacy of DRIVEN-FLOW® M7-II(DFM7II) for seven drug groups was compared with Triage DOA® (Triage) using 340 autopsy urine samples taken from bodies within 1 month of death based on mass screening analysis of GC/MS and LC-MS/MS. The sensitivity to benzodiazepines was 0.56 in Triage and 0.53 in DFM7II with few false positives, and their accuracy was 0.88. Triage detected triazolo diazepine derivatives more easily than DFM7II. DFM7II detected diazepam and nitro benzodiazepines more easily than Triage. There were nine amphetamine false-positive cases of more than 10 days after death in Triage, but these were absent in DFM7II during this period. The accuracy of amphetamines for Triage was 0.96 and for DFM7II was 1. Tricyclic antidepressant (TCA) was detected in five cases by mass analysis, while there were four false-positive cases using Triage and eight cases using DFM7II. In the TCA false-positive cases of both kits, tricyclic psychotics such as chlorpromazine, carbamazepine, and quetiapine were included as well as the drug poisoning cases. There were no samples containing cocaine or THC. The accuracy of DFM7II for opiate and barbiturates was 1, but those of Triage was less than 1. Based on the above, DFM7II is a more accurate kit with fewer false-positives for target drug groups, other than TCA, than Triage.


Assuntos
Anfetamina/urina , Antidepressivos Tricíclicos/urina , Autopsia/métodos , Azepinas/urina , Benzodiazepinas/urina , Medicina Legal/métodos , Kit de Reagentes para Diagnóstico , Detecção do Abuso de Substâncias/métodos , Triazóis/urina , Reações Falso-Positivas , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...