1.
Catheter Cardiovasc Interv ; 89(5): 888-897, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27315598

RESUMO

OBJECTIVES: To quantify the impact of image optimization on absorbed radiation dose and associated risk in children undergoing cardiac catheterization. BACKGROUND: Various imaging and fluoroscopy system technical parameters including camera magnification, source-to-image distance, collimation, antiscatter grids, beam quality, and pulse rates, all affect radiation dose but have not been well studied in younger children. METHODS: We used anthropomorphic phantoms (ages: newborn and 5 years old) to measure surface radiation exposure from various imaging approaches and estimated absorbed organ doses and effective doses (ED) using Monte Carlo simulations. Models developed in the National Academies' Biological Effects of Ionizing Radiation VII report were used to compare an imaging protocol optimized for dose reduction versus suboptimal imaging (+20 cm source-to-image-distance, +1 magnification setting, no collimation) on lifetime attributable risk (LAR) of cancer. RESULTS: For the newborn and 5-year-old phantoms, respectively ED changes were as follows: +157% and +232% for an increase from 6-inch to 10-inch camera magnification; +61% and +59% for a 20 cm increase in source-to-image-distance; -42% and -48% with addition of 1-inch periphery collimation; -31% and -46% with removal of the antiscatter grid. Compared with an optimized protocol, suboptimal imaging increased ED by 2.75-fold (newborn) and fourfold (5 years old). Estimated cancer LAR from 30-min of posteroanterior fluoroscopy using optimized versus suboptimal imaging, respectively was 0.42% versus 1.23% (newborn female), 0.20% versus 0.53% (newborn male), 0.47% versus 1.70% (5-year-old female) and 0.16% versus 0.69% (5-year-old male). CONCLUSIONS: Radiation-related risks to children undergoing cardiac catheterization can be substantial but are markedly reduced with an optimized imaging approach. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Fluoroscopia/efeitos adversos , Neoplasias Induzidas por Radiação/etiologia , Imagens de Fantasmas , Medição de Risco/métodos , Cateterismo Cardíaco/efeitos adversos , Pré-Escolar , Feminino , Humanos , Incidência , Recém-Nascido , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Doses de Radiação , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...