Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36562720

RESUMO

The atmospheric oxidation of chemicals has produced many new unpredicted pollutants. A microwave plasma torch-based ion/molecular reactor (MPTIR) interfacing an online mass spectrometer has been developed for creating and monitoring rapid oxidation reactions. Oxygen in the air is activated by the plasma into highly reactive oxygen radicals, thereby achieving oxidation of thioethers, alcohols, and various environmental pollutants on a millisecond scale without the addition of external oxidants or catalysts (6 orders of magnitude faster than bulk). The direct and real-time oxidation products of polycyclic aromatic hydrocarbons and p-phenylenediamines from the MPTIR match those of the long-term multistep environmental oxidative process. Meanwhile, two unreported environmental compounds were identified with an MPTIR and measured in the actual water samples, which demonstrates the considerable significance of the proposed device for both predicting the environmental pollutants (non-target screening) and studying the mechanism of atmospheric oxidative processes.

2.
Lab Chip ; 17(9): 1655-1665, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28418438

RESUMO

As an absolute quantification method at the single-molecule level, digital PCR has been widely used in many bioresearch fields, such as next generation sequencing, single cell analysis, gene editing detection and so on. However, existing digital PCR methods still have some disadvantages, including high cost, sample loss, and complicated operation. In this work, we develop an exquisite scalable self-priming fractal branching microchannel net digital PCR chip. This chip with a special design inspired by natural fractal-tree systems has an even distribution and 100% compartmentalization of the sample without any sample loss, which is not available in existing chip-based digital PCR methods. A special 10 nm nano-waterproof layer was created to prevent the solution from evaporating. A vacuum pre-packaging method called self-priming reagent introduction is used to passively drive the reagent flow into the microchannel nets, so that this chip can realize sequential reagent loading and isolation within a couple of minutes, which is very suitable for point-of-care detection. When the number of positive microwells stays in the range of 100 to 4000, the relative uncertainty is below 5%, which means that one panel can detect an average of 101 to 15 374 molecules by the Poisson distribution. This chip is proved to have an excellent ability for single molecule detection and quantification of low expression of hHF-MSC stem cell markers. Due to its potential for high throughput, high density, low cost, lack of sample and reagent loss, self-priming even compartmentalization and simple operation, we envision that this device will significantly expand and extend the application range of digital PCR involving rare samples, liquid biopsy detection and point-of-care detection with higher sensitivity and accuracy.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Linhagem Celular , Desenho de Equipamento , Fractais , Humanos , Células-Tronco Mesenquimais/citologia , Nanotecnologia/instrumentação
3.
Data Brief ; 5: 461-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26594657

RESUMO

This article contains schemes, original experimental data and figures for an integrated modularized microfluidic system described in "An integrated microfluidic system for bovine DNA purification and digital PCR detection [1]". In this data article, we described the structure and fabrication of the integrated modularized microfluidic system. This microfluidic system was applied to isolate DNA from ovine tissue lysate and detect the bovine DNA with digital PCR (dPCR). The DNA extraction efficiency of the microdevice was compared with the efficiency of benchtop protocol.

4.
Anal Biochem ; 491: 55-7, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26364950

RESUMO

In this paper, we described an integrated modularized microfluidic system that contained two distinct functional modules, one for nucleic acids (NA) extraction and the other for digital PCR (dPCR), allowing for detecting the bovine DNA in ovine tissue.


Assuntos
DNA/análise , Técnicas Analíticas Microfluídicas/instrumentação , Reação em Cadeia da Polimerase/instrumentação , Animais , Bovinos , DNA/isolamento & purificação , Carne/análise
5.
Biomed Microdevices ; 17(3): 9970, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26029750

RESUMO

A nanoliter self-priming compartmentalization (SPC) microfluidic chip suited for the digital polymerase chain reaction (dPCR) analysis in point-of-care testing (POCT) has been developed. This dPCR chip is fabricated of polydimethylsiloxane (PDMS). After the dPCR chip is evacuated, there will be a negative pressure environment in the chip because of the gas solubility of PDMS. The negative pressure environment can provide a self-priming power so that the sample solutions can be sucked into each reaction chamber sequentially. The whole sampling process requires no external power and is valve-free. Channels that contain water are designed around each sample panel to prevent the solvent (water) from evaporating during dPCR process. A glass coverslip is also used as a waterproof layer, which is more convenient and more efficient than other waterproof methods seen in literature. This dPCR chip allows three samples to be amplified at the same time. Each sample is distributed into 1040 reaction chambers, and each chamber is only 2.08 nL. Human ß-actin DNA solutions of known concentrations are used as the templates for the dPCR analyses to verify the sensitivity and accuracy of the method. Template DNA solutions diluted to concentrations of 300, 100 and 10 copies/µL are tested and shown that this simple, portable and self-priming dPCR chip can be used at any clinic as a real POCT technique.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/genética , Dispositivos Lab-On-A-Chip , Nanotecnologia/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Primers do DNA/genética , Desenho de Equipamento , Análise de Falha de Equipamento , Microquímica/instrumentação , Microscopia de Fluorescência/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação
6.
Biomed Microdevices ; 17(3): 64, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26022215

RESUMO

A nanoliter self-priming compartmentalization (SPC) microfluidic chip suited for the digital polymerase chain reaction (dPCR) analysis in point-of-care testing (POCT) has been developed. This dPCR chip is fabricated of polydimethylsiloxane (PDMS). After the dPCR chip is evacuated, there will be a negative pressure environment in the chip because of the gas solubility of PDMS. The negative pressure environment can provide a self-priming power so that the sample solutions can be sucked into each reaction chamber sequentially. The whole sampling process requires no external power and is valve-free. Channels that contain water are designed around each sample panel to prevent the solvent (water) from evaporating during dPCR process. A glass coverslip is also used as a waterproof layer, which is more convenient and more efficient than other waterproof methods seen in literature. This dPCR chip allows three samples to be amplified at the same time. Each sample is distributed into 1040 reaction chambers, and each chamber is only 2.08 nL. Human ß-actin DNA solutions of known concentrations are used as the templates for the dPCR analyses to verify the sensitivity and accuracy of the method. Template DNA solutions diluted to concentrations of 300, 100 and 10 copies/µL are tested and shown that this simple, portable and self-priming dPCR chip can be used at any clinic as a real POCT technique.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/genética , Dispositivos Lab-On-A-Chip , Nanotecnologia/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Primers do DNA/genética , Desenho de Equipamento , Análise de Falha de Equipamento , Microquímica/instrumentação , Microscopia de Fluorescência/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação
7.
Lab Chip ; 14(6): 1176-85, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24481046

RESUMO

An integrated on-chip valve-free and power-free microfluidic digital PCR device is for the first time developed by making use of a novel self-priming compartmentalization and simple dehydration control to realize 'divide and conquer' for single DNA molecule detection. The high gas solubility of PDMS is exploited to provide the built-in power of self-priming so that the sample and oil are sequentially sucked into the device to realize sample self-compartmentalization based on surface tension. The lifespan of its self-priming capability was about two weeks tested using an air-tight packaging bottle sealed with a small amount of petroleum jelly, which is significant for a practical platform. The SPC chip contains 5120 independent 5 nL microchambers, allowing the samples to be compartmentalized completely. Using this platform, three different abundances of lung cancer related genes are detected to demonstrate the feasibility and flexibility of the microchip for amplifying a single nucleic acid molecule. For maximal accuracy, within less than 5% of the measurement deviation, the optimal number of positive chambers is between 400 and 1250 evaluated by the Poisson distribution, which means one panel can detect an average of 480 to 4804 template molecules. This device without world-to-chip connections eliminates the constraint of the complex pipeline control, and is an integrated on-chip platform, which would be a significant improvement to digital PCR automation and more user-friendly.


Assuntos
DNA de Neoplasias/química , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Linhagem Celular Tumoral , Humanos
8.
Lab Chip ; 12(22): 4755-63, 2012 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-22986619

RESUMO

Digital nucleic acid amplification provides unprecedented opportunities for absolute nucleic acid quantification by counting of single molecules. This technique is useful for molecular genetic analysis in cancer, stem cell, bacterial, non-invasive prenatal diagnosis in which many biologists are interested. This paper describes a self-priming compartmentalization (SPC) microfluidic chip platform for performing digital loop-mediated amplification (LAMP). The energy for the pumping is pre-stored in the degassed bulk PDMS by exploiting the high gas solubility of PDMS; therefore, no additional structures other than channels and reservoirs are required. The sample and oil are sequentially sucked into the channels, and the pressure difference of gas dissolved in PDMS allows sample self-compartmentalization without the need for further chip manipulation such as with pneumatic microvalves and control systems, and so on. The SPC digital LAMP chip can be used like a 384-well plate, so, the world-to-chip fluidic interconnections are avoided. The microfluidic chip contains 4 separate panels, each panel contains 1200 independent 6 nL chambers and can be used to detect 4 samples simultaneously. Digital LAMP on the microfluidic chip was tested quantitatively by using ß-actin DNA from humans. The self-priming compartmentalization behavior is roughly predictable using a two-dimensional model. The uniformity of compartmentalization was analyzed by fluorescent intensity and fraction of volume. The results showed that the feasibility and flexibility of the microfluidic chip platform for amplifying single nucleic acid molecules in different chambers made by diluting and distributing sample solutions. The SPC chip has the potential to meet the requirements of a general laboratory: power-free, valve-free, operating at isothermal temperature, inexpensive, sensitive, economizing labour time and reagents. The disposable analytical devices with appropriate air-tight packaging should be useful for point-of-care, and enabling it to become one of the common tools for biology research, especially, in point-of-care testing.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Dimetilpolisiloxanos/química , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...