Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 44(17-18): 1342-1352, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37309725

RESUMO

Meat adulteration detection is a common concern of consumers. Here, we proposed a multiplex digital polymerase chain reaction method and a low-cost device for meat adulteration detection. Using a polydimethylsiloxane microfluidic device, polymerase chain reaction reagents could be pump-free loaded into microchambers (40 × 40 chambers) automatically. Due to the independence of multiplex fluorescence channels, deoxyribonucleic acid templates extracted from different animal species could be distinguished by one test. In this paper, we designed primers and probes for four types of meat (beef, chicken, pork, and duck) and labeled each of the four fluorescent markers (hexachlorocyclohexane [HEX], 6-carboxyfluorescein [FAM], X-rhodamine [ROX], and cyanine dyes 5 [CY5]) on the probes. Specific detection and mixed detection experiments were performed on four types of meat, realizing a limit of detection of 3 copies/µL. A mixture of four different species can be detected by four independent fluorescence channels. The quantitative capability of this method is found to meet the requirements of meat adulteration detections. This method has great potential for point-of-care testing together with portable microscopy equipment.


Assuntos
Contaminação de Alimentos , Carne , Animais , Bovinos , Contaminação de Alimentos/análise , Carne/análise , Reação em Cadeia da Polimerase Multiplex/métodos , Primers do DNA/análise , Patos
2.
Micromachines (Basel) ; 13(9)2022 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-36144017

RESUMO

Nucleic acid detection is widely used in disease diagnosis, food safety, environmental monitoring and many other research fields. The continuous development of rapid and sensitive new methods to detective nucleic acid is very important for practical application. In this study, we developed a rapid nucleic-acid detection method using polymerase chain reaction (PCR) combined with electrokinetic preconcentration based on ion concentration polarization (ICP). Using a Nafion film, the proposed ICP microfluidic chip is utilized to enrich the nucleic acid molecules amplified by PCR thermal cycles. To demonstrate the capability of the microfluidic device and the hybrid nucleic-acid detection method, we present an animal-derived component detection experiment for meat product identification applications. With the reduced cycle numbers of 24 cycles, the detection can be completed in about 35 min. The experimental results show that this work can provide a microfluidic device and straightforward method for rapid detection of nucleic acids with reduced cycle numbers.

3.
Micromachines (Basel) ; 13(6)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35744483

RESUMO

A fluorescence microscope is one of the most important tools for biomedical research and laboratory diagnosis. However, its high cost and bulky size hinder the application of laboratory microscopes in space-limited and low-resource applications. Here, in this work, we proposed a portable and cost-effective fluorescence microscope. Assembled from a set of 3D print components and a webcam, it consists of a three-degree-of-freedom sliding platform and a microscopic imaging system. The microscope is capable of bright-field and fluorescence imaging with micron-level resolution. The resolution and field of view of the microscope were evaluated. Compared with a laboratory-grade inverted fluorescence microscope, the portable microscope shows satisfactory performance, both in the bright-field and fluorescence mode. From the configurations of local resources, the microscope costs around USD 100 to assemble. To demonstrate the capability of the portable fluorescence microscope, we proposed a quantitative polymerase chain reaction experiment for meat product authenticating applications. The portable and low-cost microscope platform demonstrates the benefits in space-constrained environments and shows high potential in telemedicine, point-of-care testing, and more.

4.
Micromachines (Basel) ; 13(5)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35630259

RESUMO

Microfluidic devices offer excellent heat transfer, enabling the biochemical reactions to be more efficient. However, the precision of temperature sensing and control of microfluids is limited by the size effect. Here in this work, the relationship between the microfluids and the glass substrate of a typical microfluidic device is investigated. With an intelligent structure design and liquid metal, we demonstrated that a millimeter-scale industrial temperature sensor could be utilized for temperature sensing of micro-scale fluids. We proposed a heat transfer model based on this design, where the local correlations between the macro-scale temperature sensor and the micro-scale fluids were investigated. As a demonstration, a set of temperature-sensitive nucleic acid amplification tests were taken to show the precision of temperature control for micro-scale reagents. Comparations of theoretical and experimental data further verify the effectiveness of our heat transfer model. With the presented compensation approach, the slight fluorescent intensity changes caused by isothermal amplification polymerase chain reaction (PCR) temperature could be distinguished. For instance, the probability distribution plots of fluorescent intensity are significant from each other, even if the amplification temperature has a difference of 1 °C. Thus, this method may serve as a universal approach for micro-macro interface sensing and is helpful beyond microfluidic applications.

5.
Biosensors (Basel) ; 12(5)2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35624651

RESUMO

Cell culture plays an essential role in tissue engineering and high-throughput drug screening. Compared with two-dimensional (2D) in vitro culture, three-dimensional (3D) in vitro culture can mimic cells in vivo more accurately, including complex cellular organizations, heterogeneity, and cell-extracellular matrix (ECM) interactions. This article presents a droplet-based microfluidic chip that integrates cell distribution, 3D in vitro cell culture, and in situ cell monitoring in a single device. Using the microfluidic "co-flow step emulsification" approach, we have successfully prepared close-packed droplet arrays with an ultra-high-volume fraction (72%) which can prevent cells from adhering to the chip surface so as to achieve a 3D cell culture and make scalable and high-throughput cell culture possible. The proposed device could produce droplets from 55.29 ± 1.52 to 95.64 ± 3.35 µm, enabling the diverse encapsulation of cells of different sizes and quantities. Furthermore, the cost for each microfluidic CFSE chip is approximately USD 3, making it a low-cost approach for 3D cell culture. The proposed device is successfully applied in the 3D culture of saccharomyces cerevisiae cells with an occurrence rate for proliferation of 80.34 ± 3.77%. With low-cost, easy-to-operate, high-throughput, and miniaturization characteristics, the proposed device meets the requirements for 3D in vitro cell culture and is expected to be applied in biological fields such as drug toxicology and pharmacokinetics.


Assuntos
Técnicas de Cultura de Células , Microfluídica , Contagem de Células , Técnicas de Cultura de Células/métodos , Técnicas de Cultura de Células em Três Dimensões , Microfluídica/métodos , Engenharia Tecidual
6.
Anal Chem ; 94(9): 3939-3947, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35200004

RESUMO

Digital polymerase chain reaction (PCR) plays important roles in the detection and quantification of nucleic acid targets, while there still remain challenges including high cost, complex operation, and low integration of the instrumental system. Here, in this work, a novel microfluidic chip based on co-flow step emulsification is proposed for droplet digital PCR (ddPCR), which can achieve droplet generation, droplet array self-assembly, PCR amplification, and fluorescence detection on a single device. With the combination of single-layer lithography and punching operation, a step microstructure was constructed and it served as the key element to develop a Laplace pressure gradient at the Rayleigh-Plateau instability interface so as to achieve droplet generation. It is demonstrated that the fabrication of step microstructure is low cost, easy-to-operate, and reliable. In addition, the single droplet volume can be adjusted flexibly due to the co-flow design; thus, the ddPCR chip can get an ultrahigh upper limit of quantification to deal with DNA templates with high concentrations. Furthermore, the volume fraction of the resulting droplets in this ddPCR chip can be up to 72% and it results in closely spaced droplet arrays, makes the best of CCD camera for fluorescence detections, and is beneficial for the minimization of a ddPCR system. The quantitative capability of the ddPCR chip was evaluated by measuring template DNA at concentrations from 20 to 50 000 copies/µL. Owing to the characteristics of low cost, easy operation, excellent quantitative capability, and minimization, the proposed ddPCR chip meets the requirements of DNA molecule quantification and is expected to be applied in the point-of-care testing field.


Assuntos
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , DNA/análise , DNA/genética , Microfluídica , Ácidos Nucleicos/análise , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase em Tempo Real
7.
Cell Rep ; 36(11): 109690, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34525358

RESUMO

Recombinant bacterial colonization plays an indispensable role in disease prevention, alleviation, and treatment. Successful application mainly depends on whether bacteria can efficiently spatiotemporally colonize the host gut. However, a primary limitation of existing methods is the lack of precise spatiotemporal regulation, resulting in uncontrolled methods that are less effective. Herein, we design upconversion microgels (UCMs) to convert near-infrared light (NIR) into blue light to activate recombinant light-responsive bacteria (Lresb) in vivo, where autocrine "functional cellular glues" made of adhesive proteins assist Lresb inefficiently colonizing the gut. The programmable engineering platform is further developed for the controlled and effective colonization of Escherichia coli Nissle 1917 (EcN) in the gut. The colonizing bacteria effectively alleviate DSS-induced colitis in mice. We anticipate that this approach could facilitate the clinical application of engineered microbial therapeutics to accurately and effectively regulate host health.


Assuntos
Escherichia coli/efeitos da radiação , Raios Infravermelhos , Optogenética/métodos , Probióticos/administração & dosagem , Proteínas/química , Administração Oral , Animais , Comportamento Animal , Colite/induzido quimicamente , Colite/microbiologia , Colite/patologia , Colite/terapia , Escherichia coli/química , Escherichia coli/crescimento & desenvolvimento , Trato Gastrointestinal/metabolismo , Trato Gastrointestinal/microbiologia , Géis/química , Expressão Gênica , Masculino , Metaboloma , Camundongos , Camundongos Endogâmicos C57BL , Fator de Crescimento Transformador beta1/genética , Fator de Crescimento Transformador beta1/metabolismo
8.
Micromachines (Basel) ; 12(8)2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34442523

RESUMO

Droplet-based micromixers have shown great prospects in chemical synthesis, pharmacology, biologics, and diagnostics. When compared with the active method, passive micromixer is widely used because it relies on the droplet movement in the microchannel without extra energy, which is more concise and easier to operate. Here we present a droplet rotation-based microfluidic mixer that allows rapid mixing within individual droplets efficiently. PDMS deformation is used to construct subsidence on the roof of the microchannel, which can deviate the trajectory of droplets. Thus, the droplet shows a rotation behavior due to the non-uniform distribution of the flow field, which can introduce turbulence and induce cross-flow enhancing 3D mixing inside the droplet, achieving rapid and homogenous fluid mixing. In order to evaluate the performance of the droplet rotation-based microfluidic mixer, droplets with highly viscous fluid (60% w/w PEGDA solution) were generated, half of which was seeded with fluorescent dye for imaging. Mixing efficiency was quantified using the mixing index (MI), which shows as high as 92% mixing index was achieved within 12 mm traveling. Here in this work, it has been demonstrated that the microfluidic mixing method based on the droplet rotation has shown the advantages of low-cost, easy to operate, and high mixing efficiency. It is expected to find wide applications in the field of pharmaceutics, chemical synthesis, and biologics.

9.
Micromachines (Basel) ; 12(6)2021 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-34198559

RESUMO

Droplet digital polymerase chain reaction (ddPCR) suffers from the need for specific equipment and skilled personnel; thus, we here present a chamber-based digital PCR microfluidic device that is compatible with fluorescence image read-out systems and removes bubbles by a pre-degassed microfluidic device that consists of a pilot channel and micro chamber arrays. Digitalized PCR reagents are introduced into micro chambers, and thermocycles are taken to perform a DNA amplification process. Then, fluorescence images of a micro chamber array are read out and analyzed to obtain the total number of positive chambers. Thereby, the copy numbers of target DNA are calculated for quantitative detections. As a validation, this device is evaluated by the application of meat authentication. We performed dPCR tests using DNA templates extracted from a pure mutton DNA template with different dilutions. Then, the dPCR chip was used to identify the meat authentication using mutton-chicken mixtures with different mass ratios, showing its performance in real biotechnical applications.

10.
Micromachines (Basel) ; 11(3)2020 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-32164167

RESUMO

Microfluidic chips-in which chemical or biological fluid samples are mixed into linear or nonlinear concentration distribution profiles-have generated enormous enthusiasm of their ability to develop patterns for drug release and their potential toxicology applications. These microfluidic devices have untapped potential for varying concentration patterns by the use of one single device or by easy-to-operate procedures. To address this challenge, we developed a soft-lithography-fabricated microfluidic platform that enabled one single device to be used as a concentration maker, which could generate linear, bell-type, or even S-type concentration profiles by tuning the feed flow rate ratios of each independent inlet. Here, we present an FFRR (feed flow rate ratio) adjustment approach to generate tens of types of concentration gradient profiles with one single device. To demonstrate the advantages of this approach, we used a Christmas-tree-like microfluidic chip as the demo. Its performance was analyzed using numerical simulation models and experimental investigations, and it showed an excellent time response (~10 s). With on-demand flow rate ratios, the FFRR microfluidic device could be used for many lab-on-a-chip applications where flexible concentration profiles are required for analysis.

11.
Materials (Basel) ; 12(22)2019 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-31717693

RESUMO

The microelectrode is an essential and vital part in microsensors that are largely used in industrial, chemical, and biological applications. To obtain desired microelectrodes in great quality, it is also of great necessity and significance to develop a robust method to fabricate the microelectrode pattern. This work developed a four-terminal differential microelectrode that aims at recognizing microparticles in fluids. This microelectrode pair consisted of a high height-width ratio microelectrode array fabricated using a pre-designed microelectrode pattern (a micro-scale channel) and melted liquid metal. The surface treatment of microelectrodes was also investigated to reveal its impacts on the continuality of melting metal and the quality of the fabricated microelectrode patterns. To evaluate the performance of micro-casting fabricated electrodes, a microfluidic device was packaged using a microelectrode layer and a flow layer. Then impedance cytometer experiments were performed using sample fluids with polymer particles in two different sizes in diameter (5 µm and 10 µm). In addition, engine oil was tested on the microelectrodes as complex samples. The number of abrasive particles in the engine oil can be collected from the developed microfluidic device for further analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...