Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(5): 1419-23, 2015 May.
Artigo em Chinês | MEDLINE | ID: mdl-26415471

RESUMO

Fiber-coupling surface Plasmon resonance sensor has attractive advantages of information transmission such as small volume, anti-electric magnetic field interference, and online real-time remote detection. In order to improve the performance of the sensor, the effect of the residual fiber thickness and the silver film thickness to the sensitivity of the sensor and the depth of the resonance peaks and full width ar half maximum (FWHM) are analyzed respectively. The results show that the increasing fiber residual thickness weakens the SPR phenomenon, and that the increasing silver film thickness widens the resonance peak, while the sensitivity of the sensor does not change monotonously. Through the integration of refractive index sensing sensitivity and full width at half maximum, figure of merit is presented and regarded as the optimized objective. The optimal design is achieved in the case of the fiber residual thickness for 66. 5 µm, and the silver film thickness for 50 nm. The optimized design with the figure of merit of 98. 67 is expected to be applied in the bio-chemical sensing and analysis.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(3): 577-81, 2014 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-25208368

RESUMO

Surface plasmon resonance, which utilizes the resonance of optical evanescent wave with the metal surface plasmon wave, has been developed into a high sensitivity, rapid, label-less measurement method for chemical and biological analysis. In order to improve the spectral sensitivity in refractive index for a side polished fiber surface plasmon resonance sensor, the whole cladding layer and part of core of a multimode fiber was polished off. Additionally, an extra chrome layer with relatively high refractive index was coated on the polished zone before a gold film. The results showed that the sensor can measure the refractive index range from 1.333 to 1. 431 RIU, with the average spectral sensitivity of 4.11 x 10(3) nm RIU(-1), which is better than the reported results. Especially, in the refractive index range of 1. 417 1. 431 RIU, the sensitivity reaches to 1.09 x 10(4) nm RIU(-1). The minimum resolution of approximately 3.6 x 10(-5) RIU was estimated by a combination analysis with the sensor sensitivity and stability. The superiorities possessed by the proposed sensor in high sensitivity, wide detection range, small size and good stability and reproducibility, etc., make it a good candidate for food testing, environmental monitoring, biomedical testing and other related fields.


Assuntos
Tecnologia de Fibra Óptica , Ressonância de Plasmônio de Superfície , Desenho de Equipamento , Ouro , Fibras Ópticas , Refratometria , Reprodutibilidade dos Testes
3.
Ying Yong Sheng Tai Xue Bao ; 22(10): 2673-80, 2011 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-22263473

RESUMO

By using coupling coordinated degree model, scissors difference methods, and coupling degree model, this paper analyzed the coupling coordinated status, development speed difference, and coupling development trend between economic and environmental systems in Shenyang Metropolitan Area in 1990-2009. In the study period, the coupling level of the relations between economic and environmental development was ascending, with the coupling degree increased from 0.42 to 0.89, which reflected the more and more harmonious relationships between economy and environment. The decrease of economic development speed and the increase of environmental construction speed reduced the scissor difference of the two systems from 0.63 degrees to 0.22 degrees, demonstrating the contribution of the economic development speed to the coupling coordinated status. The coupling degree between the economic and environmental systems stretched across in a [45 degrees, 90 degrees] region, which meant that the two systems were in a co-developing status. As the discrepancy between the development speeds of the two systems became smaller, the coupling degree was closer to 45 degrees, and the two systems were becoming better coordinated.


Assuntos
Conservação dos Recursos Naturais/economia , Ecossistema , Monitoramento Ambiental/métodos , China , Cidades , Modelos Teóricos , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...