Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38896245

RESUMO

PURPOSE: To develop and validate a nomogram model that combines radiomics features, clinical factors, and coagulation function indexes (CFI) to predict intraoperative blood loss (IBL) during cesarean sections, and to explore its application in optimizing perioperative management and reducing maternal morbidity. METHODS: In this retrospective consecutive series study, a total of 346 patients who underwent magnetic resonance imaging (156 for training and 68 for internal test, center 1; 122 for external test, center 2) were included. IBL+ was defined as more than 1000 mL estimated blood loss during cesarean sections. The prediction models of IBL were developed based on machine-learning algorithms using CFI, radiomics features, and clinical factors. ROC analysis was performed to evaluate the performance for IBL diagnosis. RESULTS: The support vector machine model incorporating all three modalities achieved an AUC of 0.873 (95% CI 0.769-0.941) and a sensitivity of 1.000 (95% CI 0.846-1.000) in the internal test set, with an AUC of 0.806 (95% CI 0.725-0.872) and a sensitivity of 0.873 (95% CI 0.799-0.922) in the external test set. It was also scored significantly higher than the CFI model (P = 0.035) on the internal test set, and both the CFI (P = 0.002) and radiomics-CFI models (P = 0.007) on the external test set. Additionally, the nomogram constructed based on three modalities achieved an internal testing set AUC of 0.960 (95% CI 0.806-0.999) and an external testing set AUC of 0.869 (95% CI 0.684-0.967) in the pregnant population without a pernicious placenta previa. It is noteworthy that the AUC of the proposed model did not show a statistically significant improvement compared to the Clinical-CFI model in both internal (P = 0.115) and external test sets (P = 0.533). CONCLUSION: The proposed model demonstrated good performance in predicting intraoperative blood loss (IBL), exhibiting high sensitivity and robust generalizability, with potential applicability to other surgeries such as vaginal delivery and postpartum hysterectomy. However, the performance of the proposed model was not statistically significantly better than that of the Clinical-CFI model.

2.
J Magn Reson Imaging ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38390981

RESUMO

BACKGROUND: Different placenta accreta spectrum (PAS) subtypes pose varying surgical risks to the parturient. Machine learning model has the potential to diagnose PAS disorder. PURPOSE: To develop a cascaded deep semantic-radiomic-clinical (DRC) model for diagnosing PAS and its subtypes based on T2-weighted MRI. STUDY TYPE: Retrospective. POPULATION: 361 pregnant women (mean age: 33.10 ± 4.37 years), suspected of PAS, divided into segment training cohort (N = 40), internal training cohort (N = 139), internal testing cohort (N = 60), and external testing cohort (N = 122). FIELD STRENGTH/SEQUENCE: Coronal T2-weighted sequence at 1.5 T and 3.0 T. ASSESSMENT: Clinical characteristics such as history of uterine surgery and the presence of placenta previa, complete placenta previa and dangerous placenta previa were extracted from clinical records. The DRC model (incorporating radiomics, deep semantic features, and clinical characteristics), a cumulative radiological score method performed by radiologists, and other models (including a radiomics and clinical, the clinical, radiomics and deep learning models) were developed for PAS disorder diagnosing (existence of PAS and its subtypes). STATISTICAL TESTS: AUC, ACC, Student's t-test, the Mann-Whitney U test, chi-squared test, dice coefficient, intraclass correlation coefficients, least absolute shrinkage and selection operator regression, receiver operating characteristic curve, calibration curve with the Hosmer-Lemeshow test, decision curve analysis, DeLong test, and McNemar test. P < 0.05 indicated a significant difference. RESULTS: In PAS diagnosis, the DRC-1 outperformed than other models (AUC = 0.850 and 0.841 in internal and external testing cohorts, respectively). In PAS subtype classification (abnormal adherent placenta and abnormal invasive placenta), DRC-2 model performed similarly with radiologists (P = 0.773 and 0.579 in the internal testing cohort and P = 0.429 and 0.874 in the external testing cohort, respectively). DATA CONCLUSION: The DRC model offers efficiency and high diagnostic sensitivity in diagnosis, aiding in surgical planning. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

3.
Comput Methods Programs Biomed ; 233: 107466, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36907040

RESUMO

BACKGROUND AND OBJECTIVES: Radiomics and deep learning are two popular technologies used to develop computer-aided detection and diagnosis schemes for analysing medical images. This study aimed to compare the effectiveness of radiomics, single-task deep learning (DL) and multi-task DL methods in predicting muscle-invasive bladder cancer (MIBC) status based on T2-weighted imaging (T2WI). METHODS: A total of 121 tumours (93 for training, from Centre 1; 28 for testing, from Centre 2) were included. MIBC was confirmed with pathological examination. A radiomics model, a single-task model, and a multi-task model based on T2WI were constructed in the training cohort with five-fold cross-validation, and validation was conducted in the external test cohort. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of each model. DeLong's test and a permutation test were used to compare the performance of the models. RESULTS: The area under the ROC curve (AUC) values of the radiomics, single-task and multi-task models in the training cohort were: 0.920, 0.933 and 0.932, respectively; and were 0.844, 0.884 and 0.932, respectively, in the test cohort. The multi-task model achieved better performance in the test cohort than did the other models. No statistically significant differences in AUC values and Kappa coefficients were observed between pairwise models, in either the training or test cohorts. According to the Grad-CAM feature visualization results, the multi-task model focused more on the diseased tissue area in some samples of the test cohort compared with the single-task model. CONCLUSIONS: The T2WI-based radiomics, single-task, and multi-task models all exhibited good diagnostic performance in preoperatively predicting MIBC, in which the multi-task model had the best diagnostic performance. Compared with the radiomics method, our multi-task DL method had the advantage of saving time and effort. Compared with the single-task DL method, our multi-task DL method had the advantage of being more lesion-focused and more reliable for clinical reference.


Assuntos
Aprendizado Profundo , Neoplasias da Bexiga Urinária , Humanos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Imageamento por Ressonância Magnética , Curva ROC , Músculos/diagnóstico por imagem , Estudos Retrospectivos
4.
Eur Radiol ; 33(4): 2699-2709, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36434397

RESUMO

OBJECTIVES: To compare the diagnostic performance of a novel deep learning (DL) method based on T2-weighted imaging with the vesical imaging-reporting and data system (VI-RADS) in predicting muscle invasion in bladder cancer (MIBC). METHODS: A total of 215 tumours (129 for training and 31 for internal validation, centre 1; 55 for external validation, centre 2) were included. MIBC was confirmed by pathological examination. VI-RADS scores were provided by two groups of radiologists (readers 1 and readers 2) independently. A deep convolutional neural network was constructed in the training set, and validation was conducted on the internal and external validation sets. ROC analysis was performed to evaluate the performance for MIBC diagnosis. RESULTS: The AUCs of the DL model, readers 1, and readers 2 were as follows: in the internal validation set, 0.963, 0.843, and 0.852, respectively; in the external validation set, 0.861, 0.808, and 0.876, respectively. The accuracy of the DL model in the tumours scored VI-RADS 2 or 3 was higher than that of radiologists in the external validation set: for readers 1, 0.886 vs. 0.600, p = 0.006; for readers 2, 0.879 vs. 0.636, p = 0.021. The average processing time (38 s and 43 s in two validation sets) of the DL method was much shorter than the readers, with a reduction of over 100 s in both validation sets. CONCLUSIONS: Compared to radiologists using VI-RADS, the DL method had a better diagnostic performance, shorter processing time, and robust generalisability, indicating good potential for diagnosing MIBC. KEY POINTS: • The DL model shows robust performance for MIBC diagnosis in both internal and external validation. • The diagnostic performance of the DL model in the tumours scored VI-RADS 2 or 3 is better than that obtained by radiologists using VI-RADS. • The DL method shows potential in the preoperative assessment of MIBC.


Assuntos
Aprendizado Profundo , Neoplasias da Bexiga Urinária , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Bexiga Urinária/patologia , Músculos/patologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...