Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Nucl Cardiol ; 8(1): 113-116, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36540187

RESUMO

Since Agatston et al. first reported quantification of the coronary artery calcification score (CACS) in 1990, discussion of its clinical significance and use in diagnostic management has continued. Recent papers have reported the relationship between CACS and myocardial perfusion single photon emission computed tomography (SPECT: MPS) and its combined diagnostic value. When interpreting CACS results, it should be noted that the frequency of significant ischemia detected by MPS, likelihood of coronary artery disease (CAD), and event rate gradually increased from mild to moderate CACS (1-400). At present, high CACS is considered to be moderately consistent with abnormal MPS, and abnormal CACS in normal MPS may contribute to CAD risk stratification. However, it should be noted that CACS=0 does not completely exclude CAD, which is particularly important when using CACS as a gatekeeper for MPS. Both stand-alone computed tomography (CT) scanner and hybrid SPECT-CT scanner are available for combined risk stratification of CACS and MPS in addition to improvement of image quality with attenuation correction.

2.
Heart Vessels ; 37(8): 1411-1417, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35133499

RESUMO

Some patients with pacemakers present with first-degree atrioventricular (AV) block. To avoid right ventricular (RV) pacing, preserving intrinsic AV conduction as much as possible is recommended. However, there is no clear cutoff AV interval to determine whether intrinsic AV conduction should be preserved or RV pacing should be delivered. This study aimed to compare a pacing mode-preserving, intrinsic AV conduction with the DDD mode delivering RV pacing in terms of echocardiographic parameters in patients with first-degree AV block and to investigate whether RV pacing induces heart failure (HF). Stroke volume (SV) was measured to determine the optimal AV delay with the intrinsic AV conduction rhythm and the DDD pacing delivering RV pacing. Echocardiographic evaluation was performed for 6-month follow-up period. Seventeen patients were studied. At baseline, mean intrinsic PQ interval was 250 ± 40 ms. SV was greater with RV pacing with optimal AV delay of 160 ms than with intrinsic AV conduction rhythm in all patients. Therefore, pacemakers were set to the DDD to deliver RV pacing. During follow-up, seven patients developed HF. Mean baseline E/E' ratio in patients who developed HF (HF group) during RV pacing was higher than in patients without HF (non = HF group; 17.9 ± 8 versus 11.5 ± 2, P = 0.018) Even within HF group patients without a high baseline E/E' ratio, it increased with RV pacing (22.2 ± 6 versus 11.6 ± 2; P < 0.001). In patients with pacemaker and first-degree AV block, RV pacing with the optimal AV delay of 160 ms increased SV. However, the risk of HF may be increased with RV pacing if the E/E' ratio is > 15 during intrinsic AV conduction or RV pacing. RV pacing should be avoided in patients with high E/E' ratio under intrinsic AV conduction or RV pacing.


Assuntos
Bloqueio Atrioventricular , Insuficiência Cardíaca , Marca-Passo Artificial , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...