Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 23: 1146-1155, 2017 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-28259893

RESUMO

BACKGROUND Colorectal adenocarcinoma is the second leading cause of cancer-related death in the world. The stage of the disease is related to the survival of the patient, and in early phases surgery is the main modality of treatment. The main aim of modern medicinal chemistry is to synthesize small molecules via drug designing, especially by targeting tumor cells. MATERIAL AND METHODS A new series of 19 compounds containing benzothiazole and thiazole were designed. Molecular docking studies were performed on the designed series of molecules. Compounds showing good binding affinity towards the EGFR receptor were selected for synthetic studies. Characterization of the synthesized compounds was done by FTIR, 1HNMR, Mass and C, H, N, analysis. RESULTS The anticancer evaluation of the synthesized compounds was done at NIC, USA at a single dose against colon cancer cell lines HCT 116, HCT15, and HC 29. The active compounds were further evaluated for the 5-dose testing. Compounds were designed by using docking analysis. To ascertain the interaction of EGFR tyrosine kinase binding, energy calculation was used. CONCLUSIONS The results of the present study indicate that the designed compounds show good activity against colon cancer cell lines, which may be further studied to design new potential molecules.


Assuntos
Neoplasias do Colo/patologia , Desenho de Fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Trifosfato de Adenosina , Antineoplásicos/química , Antineoplásicos/farmacologia , Benzotiazóis/química , Benzotiazóis/farmacologia , Sítios de Ligação , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Cristalografia por Raios X , Relação Dose-Resposta a Droga , Humanos , Ligação de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Simulação de Acoplamento Molecular
2.
Basic Res Cardiol ; 103(6): 587-97, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18787802

RESUMO

BACKGROUND: Cardiac marker release after percutaneous coronary interventions (PCI) reflects myocardial necrosis which is usually the result of periprocedural (micro)embolization of atherothrombotic debris and associated with impaired left ventricular function and adverse outcome. METHODS: In this prospective study, we examined 55 patients treated by direct stenting of single de-novo lesions to assess the relationship between plaque composition, as determined by preinterventional intravascular ultrasound (IVUS) with radiofrequency data (IVUS-RF) analysis (so-called Virtual Histology) versus coronary microembolization, as determined by serial measurement of cardiac markers. IVUS was performed with an electronic system and 20-MHz IVUS catheters. Serum creatine kinase (CK) and cardiac troponin I (CTnI) were determined before PCI and after 6, 12, and 24 hours. RESULTS: Plaques had a volume of 99 +/- 63 mm(3) and were composed of fibrous (61 +/- 9%) and fibro-fatty tissue (27 +/- 12%), dense calcium (4 +/- 3%), and necrotic core (NC) (8 +/- 6%). NC volume per se, volume per 10 mm of segment length, and volume % were correlated (r = 0.64, 0.66, and 0.52 respectively; all P < 0.01) with the maximum increase in cardiac markers (CK 55.4 +/- 55.7 U/l; CTnI 0.49 +/- 0.68 ng/ml). Patients in the 4th quartile of NC volume (>10.8 mm(3)) had a particularly high increase in markers (P < 0.001). In contrast, total plaque volume and plaque components other than NC had no relation with cardiac markers (ns). CONCLUSIONS: Patients with large NC in culprit lesions may experience more myocardial injury from peri-interventional microembolization. IVUS-RF assessment before PCI has the potential to identify lesions at particular high risk which may help to tailor PCI.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/patologia , Oclusão Coronária/patologia , Vasos Coronários/patologia , Embolia/patologia , Stents , Idoso , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Oclusão Coronária/sangue , Oclusão Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Creatina Quinase/sangue , Embolia/sangue , Embolia/diagnóstico por imagem , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Necrose/sangue , Necrose/diagnóstico por imagem , Necrose/patologia , Estudos Prospectivos , Índice de Gravidade de Doença , Troponina I/sangue , Ultrassonografia de Intervenção
3.
Anal Chim Acta ; 587(1): 104-9, 2007 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-17386760

RESUMO

A Ru(bpy)(3)(2+)-based electrochemiluminescence (ECL) detection coupled with capillary electrophoresis (CE) has been established for the determination of sinomenine for the first time. Optimum separation was achieved with a fused-silica capillary column (50 cm x 25 microm i.d.) and a background electrolyte of 50 mM sodium phosphate (pH 5.0) at a separation voltage of 15 kV. The content of sinomenine was detected by ECL at the detection voltage of 1.15 V (versus Ag/AgCl) with 5 mM Ru(bpy)(3)(2+) in 75 mM phosphate solution (pH 8.0) when a chemically modified platinum electrode by europium(III)-doped prussian blue analogue (Eu-PB) was used as a working electrode. Under the optimized conditions, the ECL intensity was in proportion to sinomenine concentration in the range from 0.01 to 1.0 microg mL(-1) with a detection limit of 2.0 ng mL(-1) (3sigma). The relative standard derivations of migration time and ECL intensity were 0.93 and 1.11%, respectively. The level of sinomenine in Sinomenium acutum Rehd. et Wils was easily determined with recoveries between 98.6 and 102.7%.


Assuntos
Eletroquímica/métodos , Eletroforese Capilar/métodos , Morfinanos/análise , Calibragem , Eletrodos , Eletrólitos/química , Ferrocianetos/farmacologia , Concentração de Íons de Hidrogênio , Luminescência , Medicina Tradicional Chinesa/métodos , Fosfatos/farmacologia , Extratos Vegetais , Platina/química , Rubídio/química , Solventes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...