Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mod Pathol ; 35(10): 1362-1369, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35729220

RESUMO

Ki67 has potential clinical importance in breast cancer but has yet to see broad acceptance due to inter-laboratory variability. Here we tested an open source and calibrated automated digital image analysis (DIA) platform to: (i) investigate the comparability of Ki67 measurement across corresponding core biopsy and resection specimen cases, and (ii) assess section to section differences in Ki67 scoring. Two sets of 60 previously stained slides containing 30 core-cut biopsy and 30 corresponding resection specimens from 30 estrogen receptor-positive breast cancer patients were sent to 17 participating labs for automated assessment of average Ki67 expression. The blocks were centrally cut and immunohistochemically (IHC) stained for Ki67 (MIB-1 antibody). The QuPath platform was used to evaluate tumoral Ki67 expression. Calibration of the DIA method was performed as in published studies. A guideline for building an automated Ki67 scoring algorithm was sent to participating labs. Very high correlation and no systematic error (p = 0.08) was found between consecutive Ki67 IHC sections. Ki67 scores were higher for core biopsy slides compared to paired whole sections from resections (p ≤ 0.001; median difference: 5.31%). The systematic discrepancy between core biopsy and corresponding whole sections was likely due to pre-analytical factors (tissue handling, fixation). Therefore, Ki67 IHC should be tested on core biopsy samples to best reflect the biological status of the tumor.


Assuntos
Neoplasias da Mama , Biomarcadores Tumorais/análise , Biópsia , Neoplasias da Mama/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imuno-Histoquímica , Antígeno Ki-67/análise , Receptores de Estrogênio
2.
Histopathology ; 75(2): 225-235, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31017314

RESUMO

AIMS: The nuclear proliferation marker Ki67 assayed by immunohistochemistry has multiple potential uses in breast cancer, but an unacceptable level of interlaboratory variability has hampered its clinical utility. The International Ki67 in Breast Cancer Working Group has undertaken a systematic programme to determine whether Ki67 measurement can be analytically validated and standardised among laboratories. This study addresses whether acceptable scoring reproducibility can be achieved on excision whole sections. METHODS AND RESULTS: Adjacent sections from 30 primary ER+ breast cancers were centrally stained for Ki67 and sections were circulated among 23 pathologists in 12 countries. All pathologists scored Ki67 by two methods: (i) global: four fields of 100 tumour cells each were selected to reflect observed heterogeneity in nuclear staining; (ii) hot-spot: the field with highest apparent Ki67 index was selected and up to 500 cells scored. The intraclass correlation coefficient (ICC) for the global method [confidence interval (CI) = 0.87; 95% CI = 0.799-0.93] marginally met the prespecified success criterion (lower 95% CI ≥ 0.8), while the ICC for the hot-spot method (0.83; 95% CI = 0.74-0.90) did not. Visually, interobserver concordance in location of selected hot-spots varies between cases. The median times for scoring were 9 and 6 min for global and hot-spot methods, respectively. CONCLUSIONS: The global scoring method demonstrates adequate reproducibility to warrant next steps towards evaluation for technical and clinical validity in appropriate cohorts of cases. The time taken for scoring by either method is practical using counting software we are making publicly available. Establishment of external quality assessment schemes is likely to improve the reproducibility between laboratories further.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama , Imuno-Histoquímica/normas , Antígeno Ki-67/análise , Patologia Clínica/normas , Feminino , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
3.
Mod Pathol ; 28(6): 778-86, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25698062

RESUMO

Although an important biomarker in breast cancer, Ki67 lacks scoring standardization, which has limited its clinical use. Our previous study found variability when laboratories used their own scoring methods on centrally stained tissue microarray slides. In this current study, 16 laboratories from eight countries calibrated to a specific Ki67 scoring method and then scored 50 centrally MIB-1 stained tissue microarray cases. Simple instructions prescribed scoring pattern and staining thresholds for determination of the percentage of stained tumor cells. To calibrate, laboratories scored 18 'training' and 'test' web-based images. Software tracked object selection and scoring. Success for the calibration was prespecified as Root Mean Square Error of scores compared with reference <0.6 and Maximum Absolute Deviation from reference <1.0 (log2-transformed data). Prespecified success criteria for tissue microarray scoring required intraclass correlation significantly >0.70 but aiming for observed intraclass correlation ≥0.90. Laboratory performance showed non-significant but promising trends of improvement through the calibration exercise (mean Root Mean Square Error decreased from 0.6 to 0.4, Maximum Absolute Deviation from 1.6 to 0.9; paired t-test: P=0.07 for Root Mean Square Error, 0.06 for Maximum Absolute Deviation). For tissue microarray scoring, the intraclass correlation estimate was 0.94 (95% credible interval: 0.90-0.97), markedly and significantly >0.70, the prespecified minimum target for success. Some discrepancies persisted, including around clinically relevant cutoffs. After calibrating to a common scoring method via a web-based tool, laboratories can achieve high inter-laboratory reproducibility in Ki67 scoring on centrally stained tissue microarray slides. Although these data are potentially encouraging, suggesting that it may be possible to standardize scoring of Ki67 among pathology laboratories, clinically important discrepancies persist. Before this biomarker could be recommended for clinical use, future research will need to extend this approach to biopsies and whole sections, account for staining variability, and link to outcomes.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/patologia , Imuno-Histoquímica/normas , Antígeno Ki-67/análise , Análise Serial de Tecidos/normas , Feminino , Humanos
4.
J Natl Cancer Inst ; 105(24): 1897-906, 2013 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-24203987

RESUMO

BACKGROUND: In breast cancer, immunohistochemical assessment of proliferation using the marker Ki67 has potential use in both research and clinical management. However, lack of consistency across laboratories has limited Ki67's value. A working group was assembled to devise a strategy to harmonize Ki67 analysis and increase scoring concordance. Toward that goal, we conducted a Ki67 reproducibility study. METHODS: Eight laboratories received 100 breast cancer cases arranged into 1-mm core tissue microarrays-one set stained by the participating laboratory and one set stained by the central laboratory, both using antibody MIB-1. Each laboratory scored Ki67 as percentage of positively stained invasive tumor cells using its own method. Six laboratories repeated scoring of 50 locally stained cases on 3 different days. Sources of variation were analyzed using random effects models with log2-transformed measurements. Reproducibility was quantified by intraclass correlation coefficient (ICC), and the approximate two-sided 95% confidence intervals (CIs) for the true intraclass correlation coefficients in these experiments were provided. RESULTS: Intralaboratory reproducibility was high (ICC = 0.94; 95% CI = 0.93 to 0.97). Interlaboratory reproducibility was only moderate (central staining: ICC = 0.71, 95% CI = 0.47 to 0.78; local staining: ICC = 0.59, 95% CI = 0.37 to 0.68). Geometric mean of Ki67 values for each laboratory across the 100 cases ranged 7.1% to 23.9% with central staining and 6.1% to 30.1% with local staining. Factors contributing to interlaboratory discordance included tumor region selection, counting method, and subjective assessment of staining positivity. Formal counting methods gave more consistent results than visual estimation. CONCLUSIONS: Substantial variability in Ki67 scoring was observed among some of the world's most experienced laboratories. Ki67 values and cutoffs for clinical decision-making cannot be transferred between laboratories without standardizing scoring methodology because analytical validity is limited.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/imunologia , Antígeno Ki-67/análise , Laboratórios/normas , Análise Serial de Tecidos/normas , Feminino , Humanos , Imuno-Histoquímica , Cooperação Internacional , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...