1.
Bone Joint J ; 97-B(8): 1024-30, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26224816

RESUMO

Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty (THA). Modular junctions are a potential source of such wear products and are associated with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our unit for this complication following metal-on-highly cross-linked polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as infection, and present the aggregate laboratory results and pathological findings in this series. The clinical presentation was pain, swelling or instability. Solid, cystic and mixed soft-tissue lesions were noted on imaging and confirmed intra-operatively. Corrosion at the head-neck junction was noted in all cases. No bacteria were isolated on multiple pre- and intra-operative samples yet the mean erythrocyte sedimentation rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft-tissue reactions can occur in MoP THA owing to corrosion products released from the head-neck junction. The diagnosis should be carefully considered when investigating pain after THA. This may avoid the misdiagnosis of periprosthetic infection with an unidentified organism and mitigate the unnecessary management of these cases with complete single- or two-stage exchange.


Assuntos
Artroplastia de Quadril/instrumentação , Reação a Corpo Estranho/diagnóstico , Prótese de Quadril/efeitos adversos , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sedimentação Sanguínea , Proteína C-Reativa/análise , Contagem de Células , Corrosão , Erros de Diagnóstico , Reação a Corpo Estranho/etiologia , Humanos , Metais , Polietileno , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia
2.
Soud Lek ; 56(3): 36-7, 2011 Jul.
Artigo em Tcheco | MEDLINE | ID: mdl-21887896

RESUMO

In this test were verify the possibility of the influence of windshield washer fluid containing ethanol on an alcohol breath test. The premise was that anti-freeze washer fluids used in automobiles contain ethanol, and that the use of such fluids results in ethanol vapour permeating the automobile's cabin. Tests were carried out on individuals seated on the front seats of an enclosed automobile cabin. Five different types of anti-freeze washer fluids suited for temperatures between -19 degrees C to -35 degrees C commonly available at a range of different petrol station chains throughout the Czech Republic were used. In total 34 measurements were taken. Not even in one instance could a measurement of zero be obtained within 60 seconds to 4 minutes of the use of ethanol-based washer fluid. The longest positive test lasted for 13 minutes. The highest measured value was 0.71% per hundred. Immediately after exiting the automobile and taking several breaths of fresh outside air tests were negative in all cases. All tests subjects described a clear odour of windscreen washer fluid in the cabin in all instances, which was evident even after breathalyzer tests showed zero values. It is hence verified that using ethanol-based windscreen washer fluid which is commonly accessible on our market to spray the windscreen can skew the results of breathalyzer tests in the sense of generating false positives. Due to the characteristic odour described, drivers should themselves be aware that any test undertaken could not be in his or her favour. To eliminate the apparent presence of alcohol, it is however enough to exit the cabin and to take several (2-3) breaths of fresh air to absolutely guarantee a fair test. A positive test at this stage points to a different underlying reason than ethanol-based windscreen washer fluid being used.


Assuntos
Automóveis , Testes Respiratórios , Etanol/análise , Reações Falso-Positivas , Humanos