Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin J Gastroenterol ; 14(3): 918-922, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33743140

RESUMO

Autoimmune pancreatitis is a rare, distinct and increasingly recognized form of chronic inflammatory pancreatic disease secondary to an underlying autoimmune mechanism. We report on a 14-year-old boy who developed autoimmune pancreatitis, while he was under treatment with eltrombopag for chronic immune thrombocytopenia. Therapy with corticosteroids resulted in complete remission of both. This is the first report on the co-occurrence of autoimmune pancreatitis and chronic immune thrombocytopenia in childhood, and clinicians should be aware of this rare association, because early diagnosis and therapy of autoimmune pancreatitis may prevent severe complications.


Assuntos
Doenças Autoimunes , Pancreatite Autoimune , Pancreatite , Púrpura Trombocitopênica Idiopática , Adolescente , Doenças Autoimunes/complicações , Doença Crônica , Humanos , Masculino , Pâncreas , Pancreatite/complicações , Púrpura Trombocitopênica Idiopática/complicações , Púrpura Trombocitopênica Idiopática/tratamento farmacológico
2.
Biochem Med (Zagreb) ; 27(3): 030710, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29180918

RESUMO

INTRODUCTION: Faecal calprotectin (FC) is a routinely used marker for identifying and monitoring children with inflammatory bowel disease (IBD). This non-invasive test is useful for screening children with gastrointestinal symptoms to avoid unnecessary invasive procedures. In this study, we validated for the first time the performance of a fully automated particle-enhanced turbidimetric immunoassay (PETIA) on the VITROS® 5600 analyzer for measurement of FC in symptomatic children and adolescents. MATERIALS AND METHODS: For performance validation of the PETIA (fCAL® turbo, Bühlmann Laboratories, Switzerland) on the VITROS® 5600 analyzer (Ortho Clinical Diagnostics, USA) limit of quantitation (LoQ), linearity, precision data and calibration curve stability were defined. Additionally, 95 faecal samples were measured using the PETIA, an enzyme-linked immunosorbent assay (ELISA; fCAL®, Bühlmann Laboratories, Switzerland) and a semi-quantitative lateral flow assay (Quantum Blue Reader®, Bühlmann Laboratories, Switzerland) for agreement evaluation. RESULTS: The LoQ for calprotectin using PETIA on the VITROS® 5600 analyzer was 21 µg/g. The linearity range was 20 - 2100 µg/g and the precision study showed a total coefficient of variation (CV) between 2.3% and 8.9%. The calibration curve was stable for 4 weeks. Using the clinical samples quantifiable by PETIA, ELISA and the semi-quantitative lateral flow assay, Passing-Bablok regression analysis and Bland-Altman plots showed good agreement. CONCLUSIONS: Due to good performance characteristics and agreement with established methods, the fully automated PETIA on the routine chemistry analyzer VITROS® 5600 is a new analytical option for the rapid determination of FC.


Assuntos
Ensaio de Imunoadsorção Enzimática , Fezes/química , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Automação , Calibragem , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Lactente , Doenças Inflamatórias Intestinais/diagnóstico , Limite de Detecção , Masculino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...