Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35459077

RESUMO

Optically pumped magnetometers (OPMs) are new, room-temperature alternatives to superconducting quantum interference devices (SQUIDs) for measuring the brain's magnetic fields. The most used OPM in MagnetoEncephaloGraphy (MEG) are based on alkali atoms operating in the spin-exchange relaxation-free (SERF) regime. These sensors do not require cooling but have to be heated. Another kind of OPM, based on the parametric resonance of 4He atoms are operated at room temperature, suppressing the heat dissipation issue. They also have an advantageous bandwidth and dynamic range more suitable for MEG recordings. We quantitatively assessed the improvement (relative to a SQUID magnetometers array) in recording the magnetic field with a wearable 4He OPM-MEG system through data simulations. The OPM array and magnetoencephalography forward models were based on anatomical MRI data from an adult, a nine-year-old child, and 10 infants aged between one month and two years. Our simulations showed that a 4He OPMs array offers markedly better spatial specificity than a SQUID magnetometers array in various key performance areas (e.g., signal power, information content, and spatial resolution). Our results are also discussed regarding previous simulation results obtained for alkali OPM.


Assuntos
Magnetoencefalografia , Supercondutividade , Adulto , Álcalis , Animais , Criança , Decapodiformes , Humanos , Lactente , Campos Magnéticos , Magnetoencefalografia/métodos , Masculino
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 2948-2951, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060516

RESUMO

Electrohysterogram source imaging, i.e., moving from the electrode/sensor space to the source space using EHG signals, provide an estimate of spatial distributions of uterine activity at millisecond scale. This paper aims to study the ability of different distributed source localization methods to recover uterine electrical activity sources. Performance was quantified using a detection accuracy index. Our result suggests that the variation based method is able to reconstruct extended uterus sources with the overall high accuracy, where the increasing of the electrodes numbers and the decreasing of the fat thickness induce a better accuracy in localization.


Assuntos
Útero , Eletrodos , Feminino , Humanos , Gravidez , Contração Uterina , Monitorização Uterina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...