1.
Radiat Oncol ; 16(1): 189, 2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34565439

RESUMO

BACKGROUND: MR-guided online adaptive stereotactic body radiation therapy (SBRT) for prostate cancer aims to reduce toxicity by full compensation of interfractional uncertainties. However, the process of online adaptation currently takes approximately 45 min during which intrafractional movements remain unaccounted for. This study aims to analyze the dosimetric benefit of online adaptation and to evaluate its robustness over the duration of one treatment fraction. METHODS: Baseline MR-scans at a MR-linear accelerator were acquired for ten healthy male volunteers for generation of mock-prostate SBRT plans with a dose prescription of 5 × 7.25 Gy. On a separate day, online MR-guided adaptation (ViewRay® MRIdian) was performed, and thereafter MR images were acquired every 15 min for 1 h to assess the stability of the adapted plan. RESULTS: A dosimetric benefit of online MR-guided adaptive re-planning was observed in 90% of volunteers. The median D95CTV- and D95PTV-coverage was improved from 34.8 to 35.5 Gy and from 30.7 to 34.6 Gy, respectively. Improved target coverage was not associated with higher dose to the organs at risk, most importantly the rectum (median D1ccrectum baseline plan vs. adapted plan 33.3 Gy vs. 32.3 Gy). The benefit of online adaptation remained stable over 45 min for all volunteers. However, at 60 min, CTV-coverage was below a threshold of 32.5 Gy in 30% of volunteers (30.6 Gy, 32.0 Gy, 32.3 Gy). CONCLUSION: The dosimetric benefit of MR-guided online adaptation for prostate SBRT was robust over 45 min in all volunteers. However, intrafractional uncertainties became dosimetrically relevant at 60 min and we therefore recommend verification imaging before delivery of MR-guided online adapted SBRT.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia de Intensidade Modulada
2.
Radiat Oncol ; 13(1): 225, 2018 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-30458819

RESUMO

Following publication of the original article [1], the authors reported that one of the authors' names was processed incorrectly.

3.
Radiat Oncol ; 13(1): 170, 2018 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-30201017

RESUMO

BACKGROUND: Automated treatment planning and/or optimization systems (ATPS) are in the process of broad clinical implementation aiming at reducing inter-planner variability, reducing the planning time allocated for the optimization process and improving plan quality. Five different ATPS used clinically were evaluated for advanced head and neck cancer (HNC). METHODS: Three radiation oncology departments compared 5 different ATPS: 1) Automatic Interactive Optimizer (AIO) in combination with RapidArc (in-house developed and Varian Medical Systems); 2) Auto-Planning (AP) (Philips Radiation Oncology Systems); 3) RapidPlan version 13.6 (RP1) with HNC model from University Hospital A (Varian Medical Systems, Palo Alto, USA); 4) RapidPlan version 13.7 (RP2) combined with scripting for automated setup of fields with HNC model from University Hospital B; 5) Raystation multicriteria optimization algorithm version 5 (RS) (Laboratories AB, Stockholm, Sweden). Eight randomly selected HNC cases from institution A and 8 from institution B were used. PTV coverage, mean and maximum dose to the organs at risk and effective planning time were compared. Ranking was done based on 3 Gy increments for the parallel organs. RESULTS: All planning systems achieved the hard dose constraints for the PTVs and serial organs for all patients. Overall, AP achieved the best ranking for the parallel organs followed by RS, AIO, RP2 and RP1. The oral cavity mean dose was the lowest for RS (31.3 ± 17.6 Gy), followed by AP (33.8 ± 17.8 Gy), RP1 (34.1 ± 16.7 Gy), AIO (36.1 ± 16.8 Gy) and RP2 (36.3 ± 16.2 Gy). The submandibular glands mean dose was 33.6 ± 10.8 Gy (AP), 35.2 ± 8.4 Gy (AIO), 35.5 ± 9.3 Gy (RP2), 36.9 ± 7.6 Gy (RS) and 38.2 ± 7.0 Gy (RP1). The average effective planning working time was substantially different between the five ATPS (in minutes): < 2 ± 1 for AIO and RP2, 5 ± 1 for AP, 15 ± 2 for RP1 and 340 ± 48 for RS, respectively. CONCLUSIONS: All ATPS were able to achieve all planning DVH constraints and the effective working time was kept bellow 20 min for each ATPS except for RS. For the parallel organs, AP performed the best, although the differences were small.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada
4.
Phys Med Biol ; 53(15): N307-13, 2008 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-18635898

RESUMO

A non-invasive in vivo x-ray fluorescence (XRF) method of measuring bone strontium concentrations has previously been reported as a potential diagnostic tool able to detect strontium concentration in the finger and ankle bones. The feasibility of coherent normalization for (125)I-source-based finger bone strontium x-ray fluorescence (XRF) measurements is assessed here by theoretical considerations and Monte Carlo simulations. Normalization would have several advantages, among which are the correction for the signal attenuation by the overlying soft tissue, and intersubject variability in the bone size and shape. The coherent normalization of bone strontium XRF measurements presents several challenges dictated by the behaviour of the coherent cross section and mass attenuation coefficient at the energies involved. It was found that the coherent normalization alone with either 22.1 keV or 35.5 keV photons was not successful in correcting for the overlying soft tissue attenuation. However, it was found that the coherent peak at 35.5 keV was able to correct effectively for variability in the finger bone size between people. Thus, it is suggested that, if the overlying soft tissue thickness can be obtained by means of an independent measurement, the 35.5 keV peak can be used to correct for the bone size, with an overall accuracy of the normalization process of better than 10%.


Assuntos
Falanges dos Dedos da Mão/química , Espectrometria por Raios X/métodos , Estrôncio/análise , Estudos de Viabilidade , Falanges dos Dedos da Mão/citologia , Humanos , Método de Monte Carlo , Reprodutibilidade dos Testes
5.
Phys Med Biol ; 52(8): 2107-22, 2007 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-17404458

RESUMO

An x-ray fluorescence (XRF) system using 125I as the source was developed to measure strontium in bone in vivo. As part of an in vivo pilot study, 22 people were measured at two bone sites, namely the index finger and the tibial ankle joint. Ultrasound measurements were used to obtain the soft tissue thickness at each site, which was necessary to correct the signal for tissue attenuation. For all 22 people, the strontium peak was clearly distinguishable from the background, proving that the system is able to measure Sr in vivo in people having normal bone Sr levels. Monte Carlo simulations were carried out to test the feasibility and the limitations of using the coherently scattered peak at 35.5 keV as a means to normalize the signal to correct for the bone size and shape. These showed that the accuracy of the normalized Sr signal when comparing different people is about 12%. An interesting result arising from the study is that, in the measured population, significantly higher measurements of bone Sr concentration were observed in continental Asian people, suggesting the possibility of a dietary or race dependence of the bone Sr concentration or a different bone biology between races.


Assuntos
Osso e Ossos/química , Radioisótopos do Iodo/análise , Radiometria/instrumentação , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/métodos , Estrôncio/análise , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS