Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Med Robot ; 12(1): 102-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25625236

RESUMO

BACKGROUND: This work evaluated the accuracy and safety of a protocol for minimally-invasive flapless zygomatic implant placement that uses computer-guided stereolithographic mucosa-supported surgical templates. METHODS: A total of six zygomatic implants were placed in three formalin-fixed human cadaver heads, with edentulous and severely atrophic posterior maxillae. CT scans of each cadaver head were performed after zygomatic implant placement, to evaluate the lateral error (LE) at implant tip and base, and the angular error (AE) of the implant body. RESULTS: Excluding the implant placed outside the drilling channel, the LE at the implant base was less than 1 mm in all cases. The average LE at the tip was 3.86 mm, and the AE was less than 6° in all cases, with an average of 4.5°. CONCLUSION: Computer-guided minimally-invasive flapless zygomatic implant surgery remains challenging. Careful planning and perfect stability of the surgical guide are essential.


Assuntos
Implantação Dentária/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cirurgia Assistida por Computador/métodos , Zigoma/cirurgia , Cadáver , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...