Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 141: 105759, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36905707

RESUMO

This study compared the effect of using milled fiber-reinforced resin composite and Co-Cr (milled wax and lost-wax technique) frameworks for 4-unit implant-supported partial fixed dental prostheses; and also, evaluated the influence of the connector's cross-sectional geometries on the mechanical behavior. Three groups of milled fiber-reinforced resin composite (TRINIA) for 4-unit implant-supported frameworks (n = 10) with three connectors geometries (round, square, or trapezoid), and three groups of Co-Cr alloy frameworks manufactured by milled wax/lost wax and casting technique, were analyzed. The marginal adaptation was measured before cementation using an optical microscope. Then, the samples were cemented, thermomechanical cycled (load of 100 N/2 Hz, 106 cycles; 5, 37, and 55 ᵒC, a total of 926 cycles at each one), and cementation and flexure strength (maximum force) analyzed. Analysis of stress distribution in framework veneered considering resin and ceramic properties for fiber-reinforced and Co-Cr frameworks, respectively, implant, and bone was by finite element analysis under three contact points (100 N) on the central region. ANOVA and Multiple paired test-t with Bonferroni adjustment (α = 0.05) were used for data analysis. Fiber-reinforced frameworks showed better vertical adaptation (mean ranged from 26.24 to 81.48 µm) compared to the Co-Cr frameworks (mean ranged from 64.11 to 98.12 µm), contrary to horizontal adaptation (respectively, means ranged from 281.94 to 305.38 µm; and from 150.70 to 174.82 µm). There were no failures during the thermomechanical test. Cementation strength showed three times higher for Co-Cr compared to fiber-reinforced framework, as well as flexural strength (P < .001). Regarding stress distribution, fiber-reinforced had a pattern of concentration in the implant-abutment complex. There were no significant differences in stress values or changes observed among the different connector geometries or framework materials. Trapezoid connector geometry had a worse performance for marginal adaptation, cementation (fiber-reinforced 132.41 N; Co-Cr 255.68 N) and flexural strength (fiber-reinforced 222.57 N; Co-Cr 614.27 N). Although the fiber-reinforced framework showed lower cementation and flexural strength, considering the stress distribution values and absence of failures in the thermomechanical cycling test, it can be considered for use as a framework for 4-unit implant-supported partial fixed dental prostheses in the posterior mandible. Besides, results suggest that trapezoid connectors mechanical behavior did not perform well compared to round or square geometries.


Assuntos
Prótese Parcial Fixa , Resistência à Flexão , Estudos Transversais , Teste de Materiais , Resinas Compostas , Ligas de Cromo , Análise do Estresse Dentário , Materiais Dentários , Estresse Mecânico
2.
Mater Sci Eng C Mater Biol Appl ; 81: 144-147, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28887958

RESUMO

PURPOSE: To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. MATERIAL AND METHODS: An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt­chromium (G3, Co-Cr, CAD/CAM) and cobalt­chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. RESULTS: Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). CONCLUSION: The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure.


Assuntos
Dentaduras , Implantes Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Humanos , Mandíbula
3.
Int J Oral Maxillofac Implants ; 32(4): e199-e206, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28708912

RESUMO

PURPOSE: The aim of this study was to compare the bone stress generated by rehabilitation using regular and short-length Morse taper implants (11 and 5 mm, respectively) in the same context and allied with splinted (SP) and nonsplinted (NSP) prostheses in the posterior area of the mandible using finite element analysis. MATERIALS AND METHODS: Three-dimensional geometric models using regular implants (Ø4 × 11 mm) and short implants (Ø4 × 5 mm) were simulated with a left posterior mandible that had the first premolar tooth and all teeth posterior to that premolar removed. The four experimental groups were as follows: Group 1 NSP (two regular implants and one short implant rehabilitated with nonsplinted prostheses), Group 1 SP (two regular implants and one short implant rehabilitated with splinted prostheses), Group 2 NSP (one regular implant and two short implants rehabilitated with nonsplinted prostheses), and Group 2 SP (one regular implant and two short implants rehabilitated with splinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using the ANSYS Workbench software, version 10.0. RESULTS: The splinted prostheses decreased the stress to the surrounding bone of short implants. Moreover, they also decreased the stress on the surrounding bone adjacent to the tooth. However, the splinted prostheses generated higher stress in the coverage of the surrounding bone for regular intermediate implants and prominently in the bone at the implant cervical region, at the edge crest, compared with the individualized groups. CONCLUSION: The benefits in the use of splinted prostheses are notable for the preservation of the bone surrounding the short implants and tooth; however, it is necessary to evaluate each clinical situation because, in this context, the regular implants are at higher stress than the individualized implants.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Mandíbula/cirurgia , Dente Pré-Molar , Coroas , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante/métodos , Prótese Parcial Fixa , Humanos , Dente Molar , Contenções
4.
J Craniofac Surg ; 27(3): e276-80, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27046468

RESUMO

AIMS: This study used finite element analysis to compare the biomechanical performance of splinted (SP) and nonsplinted (NSP) prostheses to regular and short length Morse taper implants in the posterior side of the mandible. METHODS: The authors used 3-dimensional geometric models of regular implants (∅4 × 11 mm) and short implants (∅4 × 5 mm) housed in the corresponding bone edges of the posterior left mandibular hemiarch involving tooth 34. The 8 experimental groups were: the control group SP (3 regular implants rehabilitated with SP), group 1SP (2 regular and 1 short implants rehabilitated with SP), group 2SP (1 regular and 2 short implants rehabilitated with SP), group 3SP (3 short implants rehabilitated with SP), the control group NSP (3 regular implants rehabilitated with NSP), group 1NSP (2 and 1 short implants rehabilitated with NSP), group 2NSP (1 regular and 2 short implants rehabilitated with NSP), and group 3NSP (3 short implants rehabilitated with NSP). Oblique forces were simulated in the molars (365 N) and premolars (200 N). Qualitative and quantitative analysis of the distribution of Von Mises equivalent stress (implants, components, and infrastructure) was performed using the AnsysWorkbench10.0 software. RESULTS AND CONCLUSIONS: The results showed that the use of SP provides several advantages and benefits, reducing the stresses placed on the implant surface, on the transmucosal abutment areas and on the interior region of the infrastructure. The use of NSP was advantageous in reducing the stresses on the abutments and in the distal interproximal area of connection between the crowns.


Assuntos
Implantes Dentários , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Imageamento Tridimensional , Modelos Dentários , Fenômenos Biomecânicos , Planejamento de Prótese Dentária , Humanos , Mandíbula/fisiologia , Mandíbula/cirurgia , Contenções , Estresse Mecânico
5.
ImplantNews ; 11(6a): 85-90, 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-733640

RESUMO

Objetivo: verificar a resistência à tração em coroas implantossuportadas cimentadas, antes e após o processo de ciclagem termomecânica. Material e métodos: foram confeccionadas18 coroas totais metálicas em liga de Ni-Cr a partir de cilindros calcináveis. As coroas foram cimentadas sobre pilares tipo munhão universal, instalados sobre implantes embutidos em bases cilíndricas de aço inoxidável. Foram testados os seguintes cimentos: cimento de óxido de zinco sem eugenol (OZ), cimento de fosfato de zinco (FZ) e cimento resinoso (RE), sendo seis corpos-de-prova para cada grupo. Após a cimentação, as coroas foram tracionadas em máquina universal de ensaios com velocidade de 0,5 mm/min. Após a limpeza, os corpos-de-prova foram novamente cimentados e submetidos ao ensaio de ciclagem termomecânica com carga de 120 N e temperatura entre 5°-55°C, sendo 500.000 ciclos mecânicos com frequência de 2 Hz e 2083 ciclos térmicos (um ciclo térmico: dois minutos). O ensaio de resistência foi realizado novamente, sendo os dados anotados e analisados estatisticamente. Resultados: a resistência de cimentação de FZ foi superior ao RE e OZ antes e após a ciclagem mecânica. A ciclagem termomecânica diminuiu significativamente a resistência de cimentação do grupo FZ. Conclusão: o cimento OZ foi o menos retentivo, seguido pelo RE e FZ, antes e após a ciclagem termomecânica. Além disso, o cimento FZ é mais susceptível às alterações pela ciclagem termomecânica.


Assuntos
Cimentos Dentários , Implantes Dentários , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa
6.
Braz Dent J ; 23(3): 212-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22814688

RESUMO

The effect of solutions of 0.2% chitosan, 15% EDTA and 10% citric acid on the microhardness of root dentin was evaluated comparatively in this study. Thirteen sound human maxillary central incisors were selected and decoronated at the cementoenamel junction. Ten roots were set into rapid polymerization acrylic resin and the root/resin block was fitted to the cutting machine to obtain slices from the cervical third. The first slice was discarded and the second slice was divided into four quadrants. Each quadrant was used to construct a sample, so that 4 specimens were obtained from each root slice, being one for each chelating solution to be tested: 15% EDTA, 10% citric acid, 0.2% chitosan and distilled water (control). The specimens were exposed to 50 µL of the solution for 5 min, and then washed in distilled water. A microhardness tester (Knoop hardness) with a 10 g load was used for 15 s. Data were analyzed statistically by one-way ANOVA and Tukey-Kramer test (α=0.05). The other 3 roots had the canals instrumented and irrigated at the end of the biomechanical preparation with the test solutions, and then examined by scanning electron microscopy (SEM) for qualitative analysis. All solutions reduced the microhardness of root dentin in a way that was statistically similar to each other (p>0.05) but significantly different from the control (p>0.05). The SEM micrographs showed that the three solutions removed smear layer from the middle third of the root canal. In conclusion, 0.2% chitosan, 15% EDTA and 10% citric acid showed similar effects in reducing dentin microhardness.


Assuntos
Quelantes/farmacologia , Quitosana/farmacologia , Ácido Cítrico/farmacologia , Dentina/efeitos dos fármacos , Ácido Edético/farmacologia , Irrigantes do Canal Radicular/farmacologia , Raiz Dentária/efeitos dos fármacos , Análise de Variância , Dureza , Testes de Dureza/métodos , Humanos , Incisivo , Microscopia Acústica , Camada de Esfregaço
7.
Braz Dent J ; 23(6): 654-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23338256

RESUMO

The aim of this study was to evaluate the effect of irrigation regimens on dentin microhardness at the furcation area of mandibular molars, using sodium hypochlorite and ethylenediaminetetraacetic acid (EDTA), individually and in alternation. The occlusal surface and the roots of 20 non-carious extracted human permanent mandibular molars were cut transversally and discarded. The tooth blocks were embedded in acrylic resin and randomly assigned to 4 groups (n=5) according to the irrigating regimens: 1% NaOCl solution, 17% EDTA solution, 1% NaOCl and 17% EDTA and distilled water (control). Knoop microhardness of dentin at the furcation area was evaluated. Data were analyzed using one-way ANOVA and Tukey's multiple comparison tests (α=0.05). The results of this study indicated that all irrigation solutions, except for distilled water (control), decreased dentin microhardness. EDTA did not show a significant difference with NaOCl/EDTA (p>0.05), but showed a significant difference with NaOCl (p<0.01). EDTA and NaOCl/EDTA showed a maximum decrease in microhardness. The 17% EDTA solution, either alone or in combination with 1% NaOCl reduced significantly dentin microhardness at the furcation area of mandibular molars.


Assuntos
Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Ácido Edético/farmacologia , Dente Molar/efeitos dos fármacos , Irrigantes do Canal Radicular/farmacologia , Hipoclorito de Sódio/farmacologia , Análise do Estresse Dentário/instrumentação , Dureza , Humanos , Mandíbula , Teste de Materiais , Preparo de Canal Radicular/métodos , Raiz Dentária/efeitos dos fármacos
8.
Braz. dent. j ; 23(3): 212-217, 2012. ilus
Artigo em Inglês | LILACS | ID: lil-641589

RESUMO

The effect of solutions of 0.2% chitosan, 15% EDTA and 10% citric acid on the microhardness of root dentin was evaluated comparatively in this study. Thirteen sound human maxillary central incisors were selected and decoronated at the cementoenamel junction. Ten roots were set into rapid polymerization acrylic resin and the root/resin block was fitted to the cutting machine to obtain slices from the cervical third. The first slice was discarded and the second slice was divided into four quadrants. Each quadrant was used to construct a sample, so that 4 specimens were obtained from each root slice, being one for each chelating solution to be tested: 15% EDTA, 10% citric acid, 0.2% chitosan and distilled water (control). The specimens were exposed to 50 μL of the solution for 5 min, and then washed in distilled water. A microhardness tester (Knoop hardness) with a 10 g load was used for 15 s. Data were analyzed statistically by one-way ANOVA and Tukey-Kramer test (α=0.05). The other 3 roots had the canals instrumented and irrigated at the end of the biomechanical preparation with the test solutions, and then examined by scanning electron microscopy (SEM) for qualitative analysis. All solutions reduced the microhardness of root dentin in a way that was statistically similar to each other (p>0.05) but significantly different from the control (p>0.05). The SEM micrographs showed that the three solutions removed smear layer from the middle third of the root canal. In conclusion, 0.2% chitosan, 15% EDTA and 10% citric acid showed similar effects in reducing dentin microhardness.


Avaliou-se o efeito das soluções de quitosana 0,2%, EDTA 15% e ácido cítrico 10% sobre a microdureza da dentina radicular. Foram utilizados 13 incisivos centrais superiores humanos, os quais tiveram suas coroas seccionadas transversalmente e desprezadas. Dez raízes foram incluídas em resina acrílica de rápida polimerização e o bloco formado raiz/resina adaptado à maquina de corte. Desprezou-se o primeiro corte transversal da porção cervical e dividiu-se o segundo, em 4 quadrantes. Cada quarto foi destinado à confecção do corpo-de-prova obtendo-se 4 espécimes para cada raiz, um para cada solução (n=10): EDTA a 15%, ácido cítrico a 10%, quitosana a 0,2% e água destilada (controle). Os espécimes receberam 50 μ L da solução por 5 min, sendo em seguida, lavados com água destilada. Utilizou-se um microdurômetro (dureza Knoop) com carga de 10 g durante 15 s. Os dados foram avaliados por meio do teste ANOVA e Tukey-Kramer (α=0,05). Três incisivos centrais superiores foram instrumentados e irrigados, ao final da biomecânica, com uma das soluções estudadas. Os espécimes foram levados para MEV e posterior análise qualitativa. Todas as soluções avaliadas reduziram a microdureza da dentina radicular de forma semelhante entre si (p>0,05) e estatisticamente diferente do controle (p<0,01). As fotomicrografias mostraram que as 3 soluções removeram a smear layer do terço médio do canal radicular. Concluiu-se que as soluções de quitosana 0,2%, EDTA 15% e ácido cítrico 10% apresentam efeito semelhante na redução da microdureza dentinária.


Assuntos
Humanos , Quelantes/farmacologia , Quitosana/farmacologia , Ácido Cítrico/farmacologia , Dentina/efeitos dos fármacos , Ácido Edético/farmacologia , Irrigantes do Canal Radicular/farmacologia , Raiz Dentária/efeitos dos fármacos , Análise de Variância , Dureza , Testes de Dureza/métodos , Incisivo , Microscopia Acústica , Camada de Esfregaço
9.
Braz. dent. j ; 23(6): 654-658, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662422

RESUMO

The aim of this study was to evaluate the effect of irrigation regimens on dentin microhardness at the furcation area of mandibular molars, using sodium hypochlorite and ethylenediaminetetraacetic acid (EDTA), individually and in alternation. The occlusal surface and the roots of 20 non-carious extracted human permanent mandibular molars were cut transversally and discarded. The tooth blocks were embedded in acrylic resin and randomly assigned to 4 groups (n=5) according to the irrigating regimens: 1% NaOCl solution, 17% EDTA solution, 1% NaOCl and 17% EDTA and distilled water (control). Knoop microhardness of dentin at the furcation area was evaluated. Data were analyzed using one-way ANOVA and Tukey's multiple comparison tests (α=0.05). The results of this study indicated that all irrigation solutions, except for distilled water (control), decreased dentin microhardness. EDTA did not show a significant difference with NaOCl/EDTA (p>0.05), but showed a significant difference with NaOCl (p<0.01). EDTA and NaOCl/EDTA showed a maximum decrease in microhardness. The 17% EDTA solution, either alone or in combination with 1% NaOCl reduced significantly dentin microhardness at the furcation area of mandibular molars.


A proposta desse estudo foi avaliar o efeito do NaOCl 1% e do ácido etilenodiaminotetracético 17% (EDTA), de forma isolada e alternada, sobre a microdureza dentinária da região da furca de molares inferiores. A superfície oclusal e as raízes de vinte molares inferiores, recém extraídos, foram cortadas transversalmente e descartadas. Os espécimes foram distribuídos em 4 grupos (n=5) de acordo com a solução irrigante utilizada. As soluções empregadas foram EDTA 17% (I), NaOCl 1% (II), NaOCl 1% e EDTA 17% (III), e água destilada (IV) (controle). Os dentes foram incluídos em blocos de resina acrílica e cortados transversalmente. A hemi-secção que melhor representou a furca dental foi lixada e polida para a avaliação da microdureza Knoop. As medidas obtidas foram analisadas utilizando-se teste ANOVA seguido do teste de comparação múltipla de Tukey (α=0,05). Os resultados desse estudo mostraram que todas as soluções, exceto o grupo controle, diminuíram a microdureza dentinária. O EDTA não apresentou diferença estatística significante em relação ao NaOCl/EDTA (p>0,05), mas foi diferente do NaOCl (p<0,01). Os grupos do EDTA e NaOCl/EDTA mostraram a maior redução da microdureza. A solução de EDTA 17%, associada ou não ao NaOCl 1% reduz, significantemente, a microdureza dentinária da furca de molares inferiores.


Assuntos
Humanos , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Ácido Edético/farmacologia , Dente Molar/efeitos dos fármacos , Irrigantes do Canal Radicular/farmacologia , Hipoclorito de Sódio/farmacologia , Análise do Estresse Dentário/instrumentação , Dureza , Mandíbula , Teste de Materiais , Preparo de Canal Radicular/métodos , Raiz Dentária/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...