Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1302: 133-42, 2013 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-23834956

RESUMO

An exhaustive GC-MS sample preparation, derivatization, mass fragmentation and acquisition study was performed, for the simultaneous analysis of chlorophenols (CPs). Selected species were 2-CP, 3-CP, 4-CP, 3,5-dichlorophenol (diCP), 2,5-diCP, 2,6-diCP, 2,4-diCP, 2,3-diCP, 3,4-diCP 2,4,6-trichlorophenol (triCP), 2,4,5-triCP, 2,3,4-triCP, 2,3,4,6-tetrachlorophenol (tetraCP) and pentachlorophenol (pentaCP), in total 14 compounds. As novelties to the field, basic researches, like systematic derivatization, mass fragmentation and acquisition methods have been optimized for the trimethylsilyl (TMS) ether derivatives of CPs. The reactivity of chlorophenols with silylating agents has not been systematically analyzed. Here, we studied the reactivity of 14 chlorophenols with five silylating reagents. The three acquisition techniques, the full scan (FS), the multiple ion monitoring (MIM), and the currently optimized multiple reaction monitoring (MRM) methods, have been compared. We developed a new analytical approach, simultaneously monitoring the fragmentation pattern of the (35)Cl and the (37)Cl containing fragment ions both as precursor and as product ions. This principle resulted in remarkable specificity and sensitivity of detection and quantification; particularly in the cases of the tetraCP and pentaCP derivatives containing the (35)Cl and the (37)Cl fragment ions at an approximate ratio of <1:1. Detailed documentation of the loss of HCl via fragmentation processes, without decomposition of the benzene ring, was attributed to the "ring-walk" mechanism described first for monochlorophenol. Critical evaluation of the derivatization and acquisition protocols was collated and validated with the same characteristics. Data of six point calibration along with the corresponding relative standard deviation percentage (RSD%) values, in the line of FS, MIM and MRM methods (r(2): 0.9987, 0.9992, 0.9989; RSD%: 8.7, 5.6, 8.1), proved to be independent on the acquisition processes. The practical utility of the optimized MRM acquisition techniques was confirmed by the quantitation of the CP contents of Danube River, tap water and distilled water samples. Results confirmed at the first time the primary importance of the MRM acquisition method, even in comparison to the MIM one: we revealed that distilled water contains higher chlorophenol content than tap water, which might have a great significance for the water industry.


Assuntos
Clorofenóis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Compostos de Trimetilsilil/análise , Água/análise
2.
J Chromatogr A ; 1264: 143-7, 2012 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-23068765

RESUMO

In order to identify and quantify fruit-lignans of Cirsium vulgare - authors introduced a special analysis system: with particular attention to the lignans enrichment/separation course. These synchronized, germination and enzymatic hydrolysis processes were followed by complementary gas and liquid chromatography, coupled with special mass selective detections (GC-MS, LC-MS/MS, LC-TOF/MS) and confirmed by nuclear magnetic resonance (NMR) spectroscopy. Mass fragmentations and NMR evidences, proved that the two main medicinal lignan constituents of the fruits of Cirsium vulgare are the neolignan-type, free balanophonin and the butyrolactone-type tracheloside. As novelty to the field, these two lignans of different chemical structures could be quantitatively extracted, separately from each others, without impurities. Balanophonin and tracheloside do accumulate in the fruits of C. vulgare, separately: balanophonin was found, in enormous high concentrations, in the fruit wall (23.2-24.9 mg/g), while in embryo part tracheloside was determined (20.3mg/g), exclusively. Consequently, the optimum source of balanophonin proved to be the fruit wall, while tracheloside, - providing trachelogenin upon enzymatic hydrolysis, - could be obtained from the embryo parts of fruits. As further novelties of the study balanophonin was identified and quantified at the first time with on-line chromatographic technique, in free form, without authentic standard compound.


Assuntos
Cromatografia Gasosa/métodos , Cromatografia Líquida/métodos , Cirsium/química , Lignanas/análise , Espectrometria de Massas/métodos , Espectroscopia de Ressonância Magnética , Espectrofotometria Ultravioleta
3.
J Chromatogr A ; 1218(45): 8264-72, 2011 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-21981935

RESUMO

An exhaustive GC-MS acquisition study was performed, for the simultaneous analysis of natural and synthetic steroids and cholic acids (in order to insert them into the last tierce of our multiresidue analysis system), such as androsterone, ß-estradiol, transdehydroandro-sterone, transdehyroandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxyprogesterone-acetate, lithocholic acid, stigmasterol, cholic acid, chenodeoxycholic acid, ß-sitosterol, ursodeoxycholic acid, 3-hydroxy-7-ketocholic acid and dehydrocholic acid, in total 26 compounds. As novelties to the field, for the trimethylsilyl (TMS) oxime ether/ester derivatives of steroids and cholic acids, at first, a tandem mass spectrometric (MS/MS), multiple reaction monitoring (MRM) type acquisition method has been developed in a single run; also for the first time, the three acquisition techniques, the full scan (FS), the selective ion monitoring (SIM), in our case the multiple ion monitoring (MIM) and the currently optimized MRM methods, have been compared; all three, in parallel, under strictly the same derivatization/instrumental conditions, both in matrix free solutions and municipal wastewater from two Hungarian wastewater treatment plants (WWTPs). Critical evaluation of the three acquisition protocols was collated on their analytical performances and validated under the same conditions. The data of six point calibration curves for FS, MIM and MRM methods, showed that both R² (0.9995, 0.9858, 0.9975) and RSD (5.3, 5.8, 5.0), for two parallel derivatizations, each injected three times, proved to be independent of the acquisition processes. Whereas, for the method limit of quantification (LOQ) and the instrument limit of quantification (ILQ) values showed considerable differences. LOQ data, were decreasing in the FS, MIM, MRM line (expressed in ng/L), for all steroids and cholic acids. The same trend was determined in terms of the ILQ values. The practical utility of the optimized acquisition techniques was confirmed by the quantitation of the steroids and cholic acids contents of wastewater samples. Results confirmed the importance of the MRM acquisition method, even in comparison to the MIM one: with particular interest in selected cases: avoiding the extreme overestimation of the ß-estradiol (156-1325%) and that of the ethinylestradiol (582-831%) concentrations in the wastewater samples.


Assuntos
Ácidos Cólicos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/análise , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Calibragem , Ácidos Cólicos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Esgotos/química , Extração em Fase Sólida , Esteroides/química , Poluentes Químicos da Água/química
4.
J Chromatogr A ; 1218(14): 1878-90, 2011 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-21367426

RESUMO

This paper reports the extension of our multiresidue analysis (MA) procedure with 18 natural and synthetic steroids; permitting the identification and quantification, in total of 81 pollutants from one solution, by a single injection, as their trimethylsilyl (TMS)-oxime ether/ester derivatives, by gas chromatography-mass spectrometry (GC-MS), within 31 min. As a novelty to the field, basic researches, such as fragmentation pattern analysis and derivatization optimization studies were performed for androsterone, transdehydroandrosterone, transandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxy-progesterone-acetate, stigmasterol and ß-sitosterol. Results confirmed that (i) the TMS oxime-ether derivatives of the keto steroids provide from 1.40 times (gestodene) up to 4.25 times (norethisterone) higher responses compared to their TMS-ether ones, and (ii) the distribution of syn/anti oximes is characteristic to the ketosteroid species examined. Based on our optimized mass fragmentation, solid phase extraction (SPE) and derivatization studies separations have been performed in the total ion current (TIC) mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Responses, obtained with derivatized standards proved to be linear (hydroxysteroids), or have been calculated from calibration curves (ketosteroids) in the range of 1.88-750ng/L levels. Limit of quantitation (LOQ) values varied between 1.88ng/L and 37.5ng/L concentrations. The most important practical messages of this work are the high androsterone (0.744-4.28µg/L), transandrosterone (0.138-4.00µg/L), coprostanol (2.11-302µg/L), cholesterol (0.308-41µg/L), stigmasterol (1.21-8.40µg/L) and ß-sitosterol (1.12-11.0µg/L) contents of influent wastewaters. ß-Estradiol (100ng/L) and estriol (54ng/L) were found in one influent sample, only. Reproducibilities, characterized with the relative standard deviation percentages (RSD%) of measurements, varied between 1.73 RSD% (ß-estradiol) and 5.4 RSD% (stigmasterol), with an average of 4.82 RSD%.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/química , Poluentes Químicos da Água/química , Éteres/química , Oximas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Esgotos/química , Extração em Fase Sólida , Esteroides/análise , Compostos de Trimetilsilil/química , Poluentes Químicos da Água/análise
5.
Talanta ; 82(2): 600-7, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20602942

RESUMO

In this paper authors describe a GC-MS acquisition study, relating to the most common, non-steroidal anti-inflammatory drugs (NSAIDs), such as ibuprofen, naproxen, ketoprofen and diclofenac. As novelties to the field, for the trimethylsilyl (TMS) oxime ester derivatives of NSAIDs, at first, a tandem mass spectrometric (MS/MS) acquisition method has been developed, and, also for the first time, the three acquisition techniques, the full scan (FS), the selective ion monitoring (SIM) and the currently optimized MS/MS ones, have been compared: all three in parallel, under strictly the same derivatization/instrumental conditions, both from model solutions and from the Danube River samples. Critical evaluation of the three acquisition protocols was collated on their analytical performances and validated with the same characteristics like the six point calibration curve, the relative standard deviation percentages (RSD%) of parallel tests, the limit of quantitation (LOQ) and the instrumental limit of quantitation (ILQ) values. Data of six point calibration (r(2)>or=0.997) and RSD% (average: 5.8 RSD%) values proved to be independent on the acquisition methods, while, LOQ and ILQ values furnished considerable differences. Decreasing LOQ data, (expressed in ng/L concentrations) were obtained in the FS, SIM, MS/MS line for ibuprofen (1.0, 0.43, 0.41), naproxen (1.1, 1.0, 0.42), ketoprofen (2.6, 1.0, 0.49) and diclofenac (1.4, 0.41, 0.21), respectively. The same trend was determined in terms of the ILQ values. The practical utility of the optimized MS/MS technique was confirmed by the quantitation of the NSAID contents of the Danube River samples, determined by all three acquisition techniques. Results obtained confirmed the primary importance of the MS/MS acquisition method, even in comparison to the SIM one: avoiding the extreme overestimation of the ibuprofen (approximately 100%) and ketoprofen (approximately 400%) concentrations in the Danube River samples.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Rios/química , Anti-Inflamatórios não Esteroides/química , Diclofenaco/análise , Ibuprofeno/análise , Cetoprofeno/análise , Limite de Detecção , Naproxeno/análise , Poluentes Químicos da Água/análise
6.
Acta Biol Hung ; 61 Suppl: 136-48, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21565772

RESUMO

To check the importance of Cd-induced iron deficiency in Cd stress, symptoms of Cd stress were compared with those of iron deficiency or the combination of these two stresses. Poplar plants grown in hydroponics with Fe-EDTA (e) or Fe-citrate (c) up to four-leaf stage were treated for two weeks either by the withdrawal of iron (Fedef), or supplying 10 µM Cd(NO3)2 in the presence (Cad) or absence of an iron source (Fedef + Cad). Cadmium and iron content of leaves developing under the stress was in the order of cCad > eCad > cFedef + Cad and cCad ≈ eFedef ≈ cFedef + Cad < eCad < cFedef, respectively. Growth inhibition was much stronger in Cad than Fedef plants. The inhibitory effects on CO2 fixation, maximal and actual efficiency of PSII, chlorophyll synthesis, as well as the stimulation of the accumulation of violaxanthin cycle components and increase in non-photochemical quenching were the strongest in cFedef+Cad plants, otherwise these parameters changed parallel to the iron deficiency of leaves. Tendency of changes in thylakoid composition were similar under Cad treatments and strong iron deficiency: particularly PSI and LHCII decreased. Therefore, the development of the photosynthetic apparatus under Cd stress was mainly influenced by the Cd-induced strong iron deficiency, while leaf growth was affected primarily by the presence of Cd.


Assuntos
Cádmio/metabolismo , Ferro/metabolismo , Fotossíntese , Folhas de Planta/crescimento & desenvolvimento , Populus/metabolismo , Folhas de Planta/metabolismo , Populus/crescimento & desenvolvimento
7.
J Chromatogr A ; 1216(12): 2288-301, 2009 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-19201001

RESUMO

This paper reports a multiresidue analysis procedure which permits the identification and quantification of sixty-three water-soluble pollutants. Subsequent to their solid-phase extraction (SPE) enrichment, analyses of species have been carried out from one solution, by a single injection, as their trimethylsilyl-oxime ether/ester derivatives, by gas chromatography-mass spectrometry, within 31min. Based on our optimized extraction, derivatization and mass fragmentation studies separation have been performed in the total ion current mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Including various pharmaceuticals, benzoic acid, its substituted species, different aromatic carboxylic acids, cholic acids, unsaturated and saturated fatty acids, aliphatic dicarboxylic acids, as well as synthetic pollutants of various origins (2,4-di-tert-butylphenol, different phthalates). Standard compounds were added to 500 mL effluent wastewater samples, at three concentrations (1-5 microg/L, 5-10 microg/L and 10-20 microg/L). Recoveries, using the Waters Oasis cartridges performing extractions at pH 2, pH 4 and pH 7 proved to be the optimum at pH 4 (average recoveries (94.5%), except for cholesterol (10%), paracetamol (18%) and 2,5-dihydroxybenzoic acid (25%). Carbamazepine could be recovered at pH 7, only. Responses, obtained with derivatized standards proved to be linear in the range of 4-80 microg/L levels. Limit of quantitation values varied between 0.92 ng/L (4-hydroxyphenylacetic acid) and 600 ng/L (dehydrocholic acid) concentrations. One of the most important messages of this work is the confirmation of the origin of blank values. It was shown that contaminants, mainly 2,4-di-tert-butylphenol, different phthalates and fatty acids, are sourced both from the reagents and mainly from the SPE procedure, independent on the cartridge applied. Reproducibilities, characterized with the relative standard deviations (RSDs) of measurements, varied between 0.71% and 10%, with an average of 4.38% RSD. The practical utility of the method was shown by the identification and quantification of the pollutant contents of Hungarian influent and effluent wastewaters (for six consecutive months and that of the Danube River for 2 months).


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Compostos de Trimetilsilil/síntese química , Poluentes Químicos da Água/análise , Compostos Benzidrílicos , Concentração de Íons de Hidrogênio , Modelos Químicos , Fenóis/análise , Ácidos Ftálicos/análise , Reprodutibilidade dos Testes , Projetos de Pesquisa , Rios/química , Sensibilidade e Especificidade , Esgotos/química , Compostos de Trimetilsilil/análise
8.
J Chromatogr A ; 1211(1-2): 104-12, 2008 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-18849033

RESUMO

This paper presents a derivatization, mass fragmentation study relating to the most common six cholic acids, such as cholic, lithocholic, chenodeoxycholic, ursodeoxycholic, 3-hydroxy,7-ketocholanic and dehydrocholic acids, identified and quantified as pollutants in the aquatic environment at the first time. Derivatizations have been performed with the two-step process (1: oximation, 2: silylation) varying the time and temperature of both reactions. Optimum responses have been obtained after 30 min oximation with hydroxylamine.HCl and 90 min silylation with hexamethyldisilazane and trifluoroacetic acid at 70 degrees C. Fragmentation patterns of the trimethylsilyl (oxime) ether/ester derivatives of all six cholic acids provided the theoretically expected, fully derivatized compounds. Reproducibility/linearity of derivatives calculated on the basis of the corresponding selective fragment ions, characterized by the relative standard deviation percentages of measurements, proved to be < or =4.9 (RSD%). The practical utility of the method was shown by the identification and quantification of cholic acids as pollutants in the aquatic environment. Subsequently to a solid phase extraction study varying the pH of extractions (pH 2, pH 4 and pH 7), applying the OASIS cartridges, it has been confirmed that the recoveries for all six cholic acids are acceptable, varying between 77% and 104%, and are independent on the pH. The total cholic acid content of a Hungarian wastewater plants' influent wastewater varied between 184 microg/L and 356 microg/L, while the Danube rivers' cholic acid content was 4.1 microg/L, only.


Assuntos
Ácidos Cólicos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Poluentes Químicos da Água/análise , Hungria , Hidroxilamina/síntese química , Compostos de Organossilício/síntese química , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos
9.
Talanta ; 76(3): 642-50, 2008 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-18585333

RESUMO

This paper reports a derivatization, mass fragmentation study relating to the most common, non-steroidal anti-inflammatory drugs (NSAIDs), such as ibuprofen, naproxen, ketoprofen and diclofenac, identified and quantified in the aquatic environment. Derivatizations have been performed with four silylation reagents in order to select the most proper one, taking into account analytical and financial points of view, equally. The tested reagents were N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA), N-methyl-N-tert-butyldimethylsilyl-trifluoroacetamide (MTBSTFA) and for this purpose at the first time, hexamethyldisilazan (HMDS)+trifluoroacetic acid (TFAA). Varying derivatization time and temperature, taking into consideration chemical and financial advantages, HMDS+TFAA proved to be the optimum selection. Responses of derivatives have been compared, as a function of the ionization technique (external/internal ionization), as well as on the treatment of compounds' selective fragment ions (SFIs): (i) extracting the corresponding, characteristic m/z masses from TIC elutions and (ii) from SIM elutions, in parallel. Reproducibilities of measurements, expressed in relative standard deviation percentages (R.S.D.%), including the nanogram and the low picogram levels of injected derivatives, provided an average between 0.93 R.S.D.% and 4.11 R.S.D.%. NSAIDs' enrichment was performed with solid-phase extraction (SPE), applying the Oasis HLB (Waters) cartridges: recoveries in the 1-6 microg L(-1) range varied between 84% and 111%, with an average reproducibility of 6.4 R.S.D.%. The utility of the optimized derivatization method is presented, on monthly basis, by the identification and quantitation of the ibuprofen, naproxen, ketoprofen and diclofenac content of the influent and effluent waste-water samples obtained from a Hungarian waste-water treatment plant.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Cromatografia Gasosa-Espectrometria de Massas/normas , Poluentes Químicos da Água/análise , Diclofenaco/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hungria , Ibuprofeno/análise , Cetoprofeno/análise , Naproxeno/análise , Compostos de Trimetilsilil , Eliminação de Resíduos Líquidos
10.
Biol Trace Elem Res ; 101(2): 107-15, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15557675

RESUMO

Reference values in biological specimens are crucial to estimate the type and magnitude of environmental and occupational exposure: Because of its importance in the excretion of noxious substances and to the noninvasive mode of its collection, urine is a useful specimen for monitoring studies. Thus, the concentrations of six trace elements (Al, Co, Mo, Nb, Ni, and Ti) were determined in 100 urine samples of the Budapestian population by inductively coupled plasma-mass spectrometry. The obtained creatinine adjusted concentrations (medians) are (in microg/g) 9.9, 0.6, 53.5, 0.4, 1.5, and 8.5 for Al, Co, Mo, Nb, Ni, and Ti, respectively.


Assuntos
Oligoelementos/urina , Adulto , Feminino , Humanos , Hungria , Masculino , Espectrometria de Massas/métodos , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...