Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Med ; 12(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37240490

RESUMO

Transarterial embolization (TAE) of renal angiomyolipoma (AML) is effective in treating and preventing hemorrhage. We report our experience using EVOH with a single-center retrospective study of all AML embolized with EVOH between June 2013 and March 2022 at the Montpellier University Hospital. A total of 29 embolizations were carried out in 24 consecutive patients (mean age: 53.86 years; 21 women and 3 men) with 25 AMLs for severe bleeding, symptomatic AML, tumor size > 4 cm, or presence of aneurysm(s) > 5 mm. Data collected included imaging and clinical outcomes, tuberous sclerosis complex status, change in AML volume, rebleeding, renal function, volume and concentration of EVOH used, and complications. Out of 29 embolizations performed for 25 AMLs, four were performed in an emergency. Technical success was achieved for 24/25 AMLs. Mean AML volume reduction was 53.59% after a mean follow-up time of 446 days using MRI or CT scan. Aneurysms on angiogram and the symptomatological nature of AML, as well as secondary TAE and multiple arterial pedicles, were statistically associated (p < 0.05). Two patients (8%) underwent nephrectomy after TAE. Four patients had a second embolization. Minor and major complication rates were 12% and 8%, respectively. Neither rebleeding nor renal function impairment was noticed. TAE of AML using EVOH is, thus, highly effective and safe.

2.
J Clin Med ; 11(21)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36362568

RESUMO

Background: Obstructive sleep apnea syndrome (OSA) is common in patients with acute myocardial infarction (AMI). Whether OSA impacts on the ventricular remodeling post-AMI remains unclear. We compared cardiac ventricular remodeling in patients assessed by cardiac magnetic resonance (CMR) imaging at baseline and six months after AMI based on the presence and severity of OSA. Methods: This prospective study included 47 patients with moderate to severe AMI. They all underwent CMR at inclusion and at six months after an AMI, and a polysomnography was performed three weeks after AMI. Left and right ventricular remodeling parameters were compared between patients based on the AHI, AHI in REM and NREM sleep, oxygen desaturation index, and daytime sleepiness. Results: Of the 47 patients, 49% had moderate or severe OSA with an AHI ≥ 15/h. No differences were observed between these patients and those with an AHI < 15/h for left ventricular end-diastolic and end-systolic volumes at six months. No association was found for left and right ventricular remodeling parameters at six months or for the difference between baseline and six months with polysomnographic parameters of OSA severity, nor with daytime sleepiness. Conclusions: Although with a limited sample size, our proof-of-concept study does not report an association between OSA and ventricular remodeling in patients with AMI. These results highlight the complexity of the relationships between OSA and post-AMI morbi-mortality.

3.
Phys Med ; 81: 155-161, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33461028

RESUMO

PURPOSE: The use of coronary computed tomography angiography (CCTA) in children remains limited by patient's irradiation, and motion artefacts impairing image quality. Triggering the acquisition at the appropriate moment, and acquiring only necessary components of the cardiac cycle could overcome these limitations. Yet, optimal cardiac intervals to perform CCTA as a function of heart rate (HR) have not yet been addressed in pediatrics. METHODS: Fifty children with coronary artery anomalies underwent a CCTA on a wide-coverage single-beat CT scanner. Multiple phases from 25% to 85% of the R-R interval were acquired and reconstructed with 10% increments. Two radiologists independently assessed motion artifacts on each cardiac phase using a 4-point semi-quantitative scale. RESULTS: At patient level, the best phase for acquisition was found in diastole for patients with HR ≤ 75 bpm and in systole for patients with HR > 85 bpm. At coronary segments and structures level, median optimal phases were reported at 70%, 80%, 47%, 50%, and 54% of the R-R interval for patients with HR ≤ 60, 61-75, 86-100, 101-130, and >130 bpm respectively. For patients with HR between 76 and 85 bpm, no clear trend could be observed. Optimal acquisition durations represented 10% (2 phases), 20% (3 phases), 50% (multiphase), 20% (3 phases), and 10% (2 phases) of the R-R interval for patients with HR ≤ 60, 61-75, 76-100, 101-130, and >130 bpm, respectively. CONCLUSIONS: Optimal positioning and duration of CCTA acquisition intervals were investigated as a function of children's HR, to reduce motion artifacts and patient's irradiation.


Assuntos
Doença da Artéria Coronariana , Pediatria , Artefatos , Criança , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Eletrocardiografia , Frequência Cardíaca , Humanos , Tomografia Computadorizada por Raios X
5.
Eur J Radiol ; 117: 26-32, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31307649

RESUMO

OBJECTIVES: To evaluate the incidence and risk factors of systemic air embolism (SAE) depicted on systematic whole thoracic CT performed after percutaneous lung biopsy. METHODS: A total of 559 CT-guided lung biopsies performed between April 2014 and May 2016 were retrospectively evaluated. SAE was defined by the presence of air in the aorta or left cardiac cavities seen on whole thorax CT images acquired after needle withdrawal. Analyzed data focused on patient (age, sex, spirometry data, emphysema on CT, therapeutics received), target lesion (location, depth, size and feature) and procedure (patient position, length of intrapulmonary needle path, number of pleural passes and of biopsy samples, operator's experience). A regression logistic model was used to identify risk factors of SAE. RESULTS: SAE was observed after 27 of the 559 lung biopsies, corresponding to a radiological incidence of 4.8% (95%CI: 3.3-7.0). Clinical incidence was 0.17% (n = 1). For 21/27 patients (78%), a targeted acquisition in the nodule area would not have included the cardiac cavities meaning SAE would have been missed. On multivariate analysis, the independent risk factors were needle path length through ventilated lung (OR: 1.13, 95%CI: 1.02-1.25, p = 0.024), number of samples (OR: 1.48, 95%CI: 1.01-2.17, p = 0.046) and prone position (OR: 3.12, 95%CI: 1.11-8.31, p = 0.031) or right-sided lateral decubitus (OR: 6.15, 95%CI: 1.66-22.85, p = 0.005). CONCLUSIONS: Asymptomatic systemic air embolism can be depicted in almost 5% of post biopsy CT examinations, when they are not limited to the targeted nodule area but include the entire thorax.


Assuntos
Biópsia por Agulha/efeitos adversos , Embolia Aérea/etiologia , Radiografia Torácica , Tomografia Computadorizada por Raios X , Idoso , Biópsia por Agulha/métodos , Embolia Aérea/terapia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
6.
Circ Cardiovasc Imaging ; 12(2): e008348, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30704282

RESUMO

BACKGROUND: The use of coronary computed tomography (CT) angiography in children with coronary artery anomalies is increasing. However, it remains technically demanding and the need to adapt acquisition parameters to a patient's cardiac characteristics has not yet been addressed. The aim of the study was to prospectively assess the feasibility of personalized multiphasic coronary CT angiography for pediatric patients. METHODS: Fifty pediatric patients (mean age 6.1±4.9 years) with coronary artery anomalies underwent a coronary CT angiography on a wide detector single-source CT equipment. Fifteen different acquisition patterns were used to trigger the acquisition at the best theoretical moment within the cardiac cycle. The appropriate pattern was automatically selected based on the patient's heart rate and heart rate variability, derived from the patient's ECG. Two independent radiologists qualitatively evaluated images. RESULTS: All acquisitions fully answered the clinical question for a mean effective dose of 0.97±0.34 mSv. Image quality qualified as good or excellent in 94% of cases (47/50). No examination was considered as not assessable but 6% (3/50) were scored as adequate for diagnosis. For these 3 patients, motion artifacts were the main cause of average image quality. No significant visual differences were reported between the different coronary arteries (mean score of 3.6 on a 4-point scale). No correlation between image quality and cardiac parameters were reported ( r=-0.19 and r=0.00, respectively for heart rate and heart rate variability). CONCLUSIONS: Personalized multiphasic coronary CT angiography acquisitions could be performed with diagnostic quality for a dose equivalent of <4 months of natural background irradiation. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03194763.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Fatores Etários , Técnicas de Imagem de Sincronização Cardíaca , Criança , Pré-Escolar , Estudos Transversais , Eletrocardiografia , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...