Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 189(3): 92, 2022 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-35132465

RESUMO

A novel coating based on hybrid monolith with metal-organic framework (MOF) onto conventional Teflon-coated magnetic stir bars was developed. For this purpose, the external surface of the Teflon stir bar was firstly vinylized in order to immobilize a glycidyl methacrylate (GMA)-based polymer onto the magnet. Then, an amino-modified MOF of type MIL-101 (NH2-MIL-101(Al)) was covalently attached to the GMA-based monolith. After the synthesis process, several parameters affecting extraction of target estrogens by stir bar sorptive extraction (SBSE) including pH, ionic strength, extraction time, stirring rate, desorption solvent, and desorption time were also investigated. The resulting hybrid monolith was evaluated as SBSE sorbent for extraction of three estrogens (estrone, 17ß-estradiol, estriol) and synthetic 17ß-ethinylestradiol from water and human urine samples followed by HPLC with fluorescence detection (excitation and emission wavelengths, 280 and 310 nm, respectively). Under the optimal experimental conditions, the analytical figures of the method were established, achieving satisfactory limits of detection in the range of 0.015-0.58 µg L-1, recovery results ranging from 70 to 95% with RSD less than 6%, and precision values (intra- and inter-extraction units) below 6%.


Assuntos
Disruptores Endócrinos/análise , Compostos de Epóxi/química , Estrogênios/análise , Estruturas Metalorgânicas/química , Metacrilatos/química , Poluentes Químicos da Água/análise , Cromatografia Líquida , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...