Rapid Commun Mass Spectrom ; 22(23): 3883-92, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18988208

RESUMO

The application of (13)C/(12)C in ecosystem-scale tracer models for CO(2) in air requires accurate measurements of the mixing ratios and stable isotope ratios of CO(2). To increase measurement reliability and data intercomparability, as well as to shorten analysis times, we have improved an existing field sampling setup with portable air sampling units and developed a laboratory setup for the analysis of the delta(13)C of CO(2) in air by isotope ratio mass spectrometry (IRMS). The changes consist of (a) optimization of sample and standard gas flow paths, (b) additional software configuration, and (c) automation of liquid nitrogen refilling for the cryogenic trap. We achieved a precision better than 0.1 per thousand and an accuracy of 0.11 +/- 0.04 per thousand for the measurement of delta(13)C of CO(2) in air and unattended operation of measurement sequences up to 12 h.


Assuntos
Ar/análise , Dióxido de Carbono/análise , Isótopos de Carbono/análise , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Dióxido de Carbono/química , Reprodutibilidade dos Testes , Projetos de Pesquisa , Sensibilidade e Especificidade
2.
Isotopes Environ Health Stud ; 44(3): 241-51, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18763182

RESUMO

Continuous analysis of the (13)C/(12)C ratio of atmospheric CO(2) (delta(13)C-CO(2)) is a powerful tool to quantify CO(2) flux strengths of the two major ecosystem processes assimilation and respiration. Traditional laboratory techniques such as isotope ratio mass spectrometry (IRMS) in combination with flask sampling are subject to technical limitations that do not allow to fully characterising variations of atmospheric delta(13)C-CO(2) at all relevant timescales. In our study, we demonstrate the strength of Fourier transform infrared (FTIR) spectroscopy in combination with a PLS-based calibration strategy for online analysis of delta(13)C-CO(2) in ambient air. The ability of the instrument to measure delta(13)C-CO(2) was tested on a grassland field-site and compared with standard laboratory-based IRMS measurements made on field-collected flask samples. Both methods were in excellent agreement, with an average difference of 0.4 per thousand (n=81). Simultaneously, other important trace gases such as CO, N(2)O and CH(4) were analysed by FTIR spectroscopy.


Assuntos
Isótopos de Carbono/análise , Gases/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Ecossistema , Temperatura