Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Orthop Surg Traumatol ; 23 Suppl 2: S295-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23412165

RESUMO

Very amusing and entertaining for the traveler, marine activities in tropical countries can be dangerous. More and more trauma caused by hazardous marine animals have been reported in recent years in the world, after maritime accidents including water sports like windsurfing, kite surfing, swimming, diving, and injuries caused by sting or contact with a marine animal. Rays and stone-fish frequently cause trauma, but there are not many cases of injury by needlefish. This case reports a case of penetrating wound of the left foot caused by a Caribbean needlefish occurred during a session of windsurfing in Martinique.


Assuntos
Traumatismos em Atletas/etiologia , Beloniformes , Traumatismos do Pé/etiologia , Ferimentos Perfurantes/etiologia , Adulto , Animais , Humanos , Masculino
2.
J Shoulder Elbow Surg ; 10(6): 546-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11743533

RESUMO

Computed tomography (CT) allows calculation of anatomic and prosthetic humeral head retroversion. The purpose of this study was to demonstrate how the retroversion angle measured by CT scan varied with changes in arm position in the CT scan reference system. A trigonometric analysis shows that the measured retroversion angle decreases when the arm is in extension and increases when it is in flexion, compared with the true retroversion angle determined perioperatively. For the same degree of flexion, or extension, the error of measurement is greater when the initial true retroversion is low. A shoulder prosthesis with 20 degrees of true head retroversion was radiologically scanned with different degrees of flexion, extension, and abduction. The results validate the theoretical analysis. Trigonometric formulas are proposed to correct the retroversion angle measured by CT scan.


Assuntos
Fenômenos Biomecânicos , Prótese Articular , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Desenho de Prótese , Ajuste de Prótese , Sensibilidade e Especificidade
4.
Rev Chir Orthop Reparatrice Appar Mot ; 87(2): 155-61, 2001 Apr.
Artigo em Francês | MEDLINE | ID: mdl-11319427

RESUMO

PURPOSE OF THE STUDY: The bipolar prosthesis was developed in an attempt to alleviate acetabular wear of conventional metallic endoprostheses. The prosthesis was designed to achieve low-friction metal-on-polyethylene inner bearing motion while decreasing shear stress across the acetabular cartilage. Although good clinical results were obtained, the principle of a persistent inner mobility was contested and some authors have assigned the delay of cartilage erosion to the shock absorption capacity of the polyethylene. The present study was focused on assessing the vibration and shock damping effect of metal monoblock and bipolar head prostheses. MATERIAL AND METHODS: The transmission of the shock wave through these two types of prostheses was studied in vitro. The two heads were first tested in a rigid environment to eliminate all external parasite frequencies. The impact excitation was applied with a hammer connected to an oscillometer. A second accelerometer was connected to the prosthesis stem. Shock wave transmission was analyzed. Secondly, the head was tested with a system vibrating in the same order of frequencies as the skeleton, with and without pre-constraint. The frequency response functions were analyzed. RESULTS: For the metallic prosthesis, the frequency of vibration recorded on the femoral stems was in a large frequency range from 0 Hz to 10 KHz. For the bipolar prosthesis, all the high frequencies of the shock wave were eliminated and only shock wave frequencies from 0 to 500 Hz were recorded. In an environmental system vibrating below 100 Hz, the metallic head did not express high frequencies of vibration. The coefficient of shock absorption was not significantly different for the two heads. DISCUSSION: In the first rigid environment, the metallic head did not filter the high frequency components of the shock wave and the bipolar head tended to eliminate high frequency components due to the flattening effect of the impulse load by the polymer. But, the lower leg is not a rigid structure and the musculo-skeletal system vibrates in frequencies below 100 Hz. In similar conditions, the increased shock-absorbing effect of the polyethylene is far more difficult to observe. For the metallic prosthesis, the recorded frequency of vibration also belongs to a small domain of frequency, from 0 Hz to 100 Hz. The range of frequency is similar for the two types of prostheses. CONCLUSION: Even though polyethylene is characterized by a more pronounced damping capacity than metallic materials, in experimental conditions simulating the vibratory characteristics of the human body, the introduction of a high-density polyethylene liner does not afford any additional shock-absorbing effect compared with a metallic head. It cannot explain cartilaginous sparing.


Assuntos
Prótese de Quadril/normas , Análise de Falha de Equipamento , Análise de Fourier , Humanos , Teste de Materiais , Polietileno , Desenho de Prótese , Falha de Prótese , Processamento de Sinais Assistido por Computador , Aço , Estresse Mecânico , Vibração/efeitos adversos , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...