1.
J Clin Ultrasound ; 27(3): 107-15, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10064407

RESUMO

PURPOSE: The aim of this study was to evaluate whether intravenous injection of an ultrasound contrast agent aids in the visualization of focal liver lesions on power Doppler images. METHODS: Fifty patients with focal liver lesions were studied by B-mode and power Doppler sonography before and after intravenous injection of the contrast agent Levovist (galactose-based microbubbles; 10 ml of a concentration of 300 mg/ml). Thirty-two patients had malignant liver lesions (19 metastases, 12 hepatocellular carcinomas, 1 cholangiocellular carcinoma), while 18 had benign lesions (12 hemangiomas, 2 focal nodular hyperplasias, 4 others). RESULTS: After contrast medium injection, the number of lesions with no intralesional flow dropped from 18 to 9. Flow signal intensity was rated subjectively as marked on contrast-enhanced images in 17 patients; only 4 patients had marked flow on precontrast images. On precontrast studies, central flow in 10 lesions and peripheral flow in 29 lesions could be observed. After enhancement, the numbers increased to 18 and 34 lesions, respectively. CONCLUSIONS: On power Doppler images, a greater number of intratumoral vessels are seen in focal liver lesions after contrast medium administration.


Assuntos
Meios de Contraste , Neoplasias Hepáticas/irrigação sanguínea , Polissacarídeos , Ultrassonografia Doppler em Cores , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Colangiocarcinoma/irrigação sanguínea , Colangiocarcinoma/diagnóstico por imagem , Hemangioma/irrigação sanguínea , Hemangioma/diagnóstico por imagem , Humanos , Hiperplasia , Aumento da Imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Circulação Hepática , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Fluxo Sanguíneo Regional
2.
J Ultrasound Med ; 17(2): 97-102, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9527579

RESUMO

The aim of this study was to establish whether an increase of maximum Doppler shift occurs in the human common carotid artery after the administration of Levovist, an ultrasonographic echo enhancer. Twenty common carotid arteries of 10 patients were examined. Spectral Doppler waveform examinations were performed before and after administration of Levovist using an Acuson 128 XP 10 and a 7.0 MHz transducer probe. Time averaged mean velocity, peak velocity, maximum Doppler shift, and spectral Doppler indices (pulsatility index, resistive index, systolic-diastolic ratio) were assessed. No significant changes in any of the measured parameters, including maximum Doppler shifts, peak velocity (P = 0.35, Wilcoxon rank sum test), pulsatility indices (P = 0.70), resistive indices (P = 0.98), or other spectral indices, were found. We conclude that an increase in Doppler shift does not inevitably occur after the administration of a signal enhancer when examining the human common carotid artery.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Meios de Contraste , Efeito Doppler , Polissacarídeos , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo , Meios de Contraste/administração & dosagem , Diástole , Feminino , Frequência Cardíaca , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Polissacarídeos/administração & dosagem , Fluxo Pulsátil , Análise de Regressão , Sístole , Resistência Vascular
3.
Rofo ; 166(6): 507-13, 1997 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-9273003

RESUMO

PURPOSE: Morphology of focal liver lesions was studied by power Doppler. Plain images and images after i.v. application of galactose-based microbubbles (Levovist, Schering AG) were compared. METHODS: 21 patients with focal liver lesions were studied by power Doppler before and after application of the signal enhancer. RESULTS: In lesions that showed short pulsations in plain studies, vascular structures were visible after application of the signal enhancer. In hepatocellular carcinomas, multiple arteries with small diameter became visible. Peripheral veins were detected in metastases. A large feeding artery was detected in 1/2 haemangiomas with flow and in a focal nodular hyperplasia. CONCLUSION: In comparison to plain amplitude-modulated colour-coded duplex ultrasound, vascular patterns of focal liver lesions were more clearly visible after injection of a signal-enhancer.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Hemangioma Cavernoso/diagnóstico por imagem , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Polissacarídeos/administração & dosagem , Ultrassonografia Doppler em Cores/métodos , Adulto , Carcinoma Hepatocelular/irrigação sanguínea , Diagnóstico Diferencial , Feminino , Hemangioma Cavernoso/irrigação sanguínea , Humanos , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X
4.
J Telemed Telecare ; 1(4): 224-8, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-9375147

RESUMO

Cooperation between physicians in hospitals in rural areas can be assisted by desktop-conferencing using a satellite link. For six weeks, medical desktop-conferencing was tested during daily clinical conferences between the Virchow-Klinikum, Berlin, and the Medical Academy, Wroclaw. The communications link was provided by the German Telekom satellite system MCS, which allowed temporary connections to be established on demand by manual dialling. Standard hardware and software were used for videoconferencing, as well as software for medical communication developed in the BERMED project. Digital data, such as computed tomography or magnetic resonance images, were transmitted by a digital data channel in parallel to the transmission of analogue video and audio signals. For conferences involving large groups of people, hardware modifications were required. These included the installation of a video projector, adaptation of the audio system with improved echo cancellation, and installation of extra microphones. Learning to use an unfamiliar communication medium proved to be uncomplicated for the participating physicians.


Assuntos
Consulta Remota , Serviços de Saúde Rural/organização & administração , Alemanha , Humanos , Multimídia , Polônia , Consulta Remota/instrumentação , Consulta Remota/métodos , População Rural , Sensibilidade e Especificidade , Software , Gravação em Vídeo
5.
Aktuelle Radiol ; 4(2): 70-4, 1994 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-8172952

RESUMO

The presently valid quality criteria of digital subtraction angiography in the body trunk area are described. The indications for intravenous and intraarterial examinations are explained; these are closely connected with the respective demands. The problem levels are analysed and update technical and methodical solutions are offered.


Assuntos
Angiografia Digital/normas , Garantia da Qualidade dos Cuidados de Saúde , Radiografia Abdominal , Humanos
6.
Rofo ; 159(3): 222-8, 1993 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-8374108

RESUMO

The present study deals with the value of CDS in liver transplantation. Between September 1988 and October 1991 CDS of hepatic vessels was carried out in 194 liver transplants. Flow direction and flow velocity in the portal vein could be demonstrated in 97%. Measurement of flow velocity indicates the extent of portal hypertension; this can be confirmed by determining flow direction in the splenic and superior mesenteric veins. In 47 of 179 patients venous collaterals were demonstrated and in 15 of 179 patients there was retrograde flow in the splenic vein. In 95% of patients CDS indicated flow direction in the hepatic artery and in 93% in the hepatic veins. Thrombosis of liver vessels (portal and hepatic veins) was demonstrated in 11 out of 13 patients by means of CDS.


Assuntos
Transplante de Fígado , Fígado/irrigação sanguínea , Síndrome de Budd-Chiari/diagnóstico por imagem , Humanos , Veias Mesentéricas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Veia Esplênica/diagnóstico por imagem , Trombose/diagnóstico por imagem , Ultrassonografia
7.
Radiology ; 187(2): 439-43, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8475287

RESUMO

The purpose of this first patient study (phase II) was to evaluate the clinical usefulness of a new echo contrast agent at transcranial Doppler ultrasonography (US). Twenty patients were selected from a group of 242 patients undergoing conventional transcranial Doppler US who had low (n = 18) or absent (n = 2) Doppler signals from the middle cerebral artery (MCA). The extent and duration of Doppler signal increase was measured in 30 MCAs and in 14 basilar arteries following the intravenous injection of a transpulmonary galactose microparticle suspension (SH U 508 A) at three concentrations (200, 300, and 400 mg/mL). Doppler waveform analysis became possible in 93% (28 of 30) of the MCAs following injection. The maximal increase in average Doppler signal intensity (11 dB at 200 mg/mL, 15 dB at 300 mg/mL, and 17 dB at 400 mg/mL) and the increase in average duration of the signal enhancement (163 seconds at 200 mg/mL, 219 seconds at 300 mg/mL, and 240 seconds at 400 mg/mL) depended on contrast agent concentration. Doppler waveform analysis became possible in 79% (11 of 14) of the basilar arteries. The intravenous injection of this new echo contrast agent markedly increases Doppler signal intensity in patients with nondiagnostic results at conventional Doppler US.


Assuntos
Circulação Cerebrovascular , Meios de Contraste , Ecoencefalografia , Polissacarídeos , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/fisiopatologia , Velocidade do Fluxo Sanguíneo , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiopatologia , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Meios de Contraste/efeitos adversos , Relação Dose-Resposta a Droga , Ecoencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissacarídeos/efeitos adversos
9.
Ultraschall Med ; 13(5): 221-7, 1992 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-1439718

RESUMO

A total of 44 patients were evaluated to compare the value of B-mode sonography, Doppler sonography and colour coded Doppler sonography. All patients were studied because of suspected lesions of the femoral arteries following diagnostic and/or therapeutic cardiac catheterisation. B-mode sonography was unable to reliably differentiate between haematoma and pseudo-aneurysms, a.v.-fistula or combined lesions. Colour coded Doppler sonography can better demonstrate haematoma and thrombi in pseudo-aneurysms. The neck of a pseudoaneurysm can be exactly depicted by colour coded Doppler sonography. A.v.-fistula is shown by colour coded Doppler sonography based on typical colour coding and the Doppler spectrum. Combined lesions of pseudo-aneurysm and a.v.-fistula cannot reliably be detected by colour coded Doppler sonography, duplex sonography and B-mode sonography.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Fístula Arteriovenosa/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Artéria Femoral/lesões , Processamento de Imagem Assistida por Computador/instrumentação , Ultrassonografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Diagnóstico Diferencial , Feminino , Artéria Femoral/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/diagnóstico por imagem
10.
Rofo ; 155(2): 179-86, 1991 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-1878546

RESUMO

In this study, 50 patients were examined by a Siemens' "Somatom Plus"; continuous 2 mm sections between the third lumbar and first sacral vertebra were obtained. The accuracy of the 3-D reconstruction software programme was checked by measuring a polyethylene phantom of a second lumbar vertebra. Reconstruction was carried out with a threshold definition of 150 Hu. In each case, four standard projections and medio-sagittal, medio-lateral and coronary sections were reconstructed, photographed and compared with axial CT sections and conventional radiographs. All these imaging procedures were suitable for the diagnosis of osteochondrosis and chondrosis. Spondylosis was diagnosed more frequently on 3-D CT. Spondylarthrosis, with narrowing of the intervertebral foramina and root canals is shown particularly well by 3-D CT, since the entire extent of these structures can be seen. 3-D surface reconstruction of the lumbar spine is useful in the diagnosis of lumbar spondylarthrosis with narrowing of the root canals and of the spinal canal. This method of axial Ct is superior to conventional radiography of the lumbar spine in the usual two planes.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Diagnóstico Diferencial , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estruturais , Doenças da Coluna Vertebral/diagnóstico por imagem , Propriedades de Superfície , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação
11.
Rofo ; 152(6): 667-72, 1990 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-2163071

RESUMO

As part of a radiological communication project (RADKOM), two PACS systems of the radiological clinic in the Rudolf Virchow University Clinic in Charlottenburg and Wedding were connected via the BERKOM network of the German post office. Within the radiology departments, all CT and MRT systems were joined through a local network. The first results have shown that the PACS stations are of value for providing uniformity of diagnosis and for radiological conferences. It is evident, however, that the speed of transfer and the architecture within the PACS system would be of crucial importance for their practicability for radiological conferences.


Assuntos
Tecnologia Radiológica/instrumentação , Telecomunicações/instrumentação , Berlim , Desenho de Equipamento , Hospitais Universitários , Sistemas de Informação , Projetos Piloto
12.
Rontgenblatter ; 42(3): 114-7, 1989 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-2652263

RESUMO

A defined region of the right lobe of the liver was measured by grey scale analysis based on similar presets according to a manual input of a Region of Interest (ROI). During 20 days, the livers of healthy subjects were tested by this method in order to test the reproducibility of the results. By prospective studies, the livers of 30 patients were examined by ultrasound and CT regarding the determination of the extent of their fatty liver disease. The value of the density of liver was determined in Hounsfield units (HU). Both methods lead to parameters that characterise the fatty content of the liver. Statistic analysis shows acceptable correlation of both methods. By means of grey scale analysis in ultrasound measurements it is possible to estimate the extent of the fatty content of liver.


Assuntos
Fígado Gorduroso/diagnóstico , Fígado/anatomia & histologia , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Idoso , Fígado Gorduroso/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...