Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 44(2): 292-300, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10918329

RESUMO

In vivo measurements of the human brain tissue water signal decay with b-factor over an extended b-factor range up to 6,000 s/mm(2) reveal a nonmonoexponential decay behavior for both gray and white matter. Biexponential parametrization of the decay curves from cortical gray (CG) and white matter voxels from the internal capsule (IC) of healthy adult volunteers describes the decay process and serves to differentiate between these two tissues. Inversion recovery experiments performed in conjunction with the extended b-factor signal decay measurements are used to make separate measurements of the spin-lattice relaxation times of the fast and slow apparent diffusion coefficient (ADC) components. Differences between the spin-lattice relaxation times of the fast and slow ADC components were not statistically significant in either the CG or IC voxels. It is possible that the two ADC components observed from the extended b-factor measurements arise from two distinct water compartments with different intrinsic diffusion coefficients. If so, then the relaxation results are consistent with two possibilities. Either the spin-lattice relaxation times within the compartments are similar or the rate of water exchange between compartments is "fast" enough to ensure volume averaged T(1) relaxation yet "slow" enough to allow for the observation of biexponential ADC decay curves over an extended b-factor range. Magn Reson Med 44:292-300, 2000.


Assuntos
Encéfalo/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Distribuição de Qui-Quadrado , Difusão , Humanos , Modelos Lineares , Água/metabolismo
2.
NMR Biomed ; 12(1): 51-62, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10195330

RESUMO

The signal decay with increasing b-factor at fixed echo time from brain tissue in vivo has been measured using a line scan Stejskal-Tanner spin echo diffusion approach in eight healthy adult volunteers. The use of a 175 ms echo time and maximum gradient strengths of 10 mT/m allowed 64 b-factors to be sampled, ranging from 5 to 6000 s/ mm2, a maximum some three times larger than that typically used for diffusion imaging. The signal decay with b-factor over this extended range showed a decidedly non-exponential behavior well-suited to biexponential modeling. Statistical analyses of the fitted biexponential parameters from over 125 brain voxels (15 x 15 x 1 mm3 volume) per volunteer yielded a mean volume fraction of 0.74 which decayed with a typical apparent diffusion coefficient around 1.4 microm2/ms. The remaining fraction had an apparent diffusion coefficient of approximately 0.25 microm2/ms. Simple models which might explain the non-exponential behavior, such as intra- and extracellular water compartmentation with slow exchange, appear inadequate for a complete description. For typical diffusion imaging with b-factors below 2000 s/mm2, the standard model of monoexponential signal decay with b-factor, apparent diffusion coefficient values around 0.7 microm2/ms, and a sensitivity to diffusion gradient direction may appear appropriate. Over a more extended but readily accessible b-factor range, however, the complexity of brain signal decay with b-factor increases, offering a greater parametrization of the water diffusion process for tissue characterization.


Assuntos
Encéfalo/fisiologia , Adulto , Encéfalo/anatomia & histologia , Difusão , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...