Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Sci Technol ; 62(8): 1898-906, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20962406

RESUMO

Because spring water quality from alpine karst aquifers can change very rapidly during event situations, water abstraction management has to be performed in near real-time. Four summer events (2005-2008) at alpine karst springs were investigated in detail in order to evaluate the spectral absorption coefficient at 254 nm (SAC254) as a real-time early warning proxy for faecal pollution. For the investigation Low-Earth-Orbit (LEO) Satellite-based data communication between portable hydrometeorological measuring stations and an automated microbiological sampling device was used. The method for event triggered microbial sampling and analyzing was already established and described in a previous paper. Data analysis including on-line event characterisation (i.e. precipitation, discharge, turbidity, SAC254) and comprehensive E. coli determination (n>800) indicated that SAC254 is a useful early warning proxy. Irrespective of the studied event situations SAC254 always increased 3 to 6 hours earlier than the onset of faecal pollution, featuring different correlation phases. Furthermore, it seems also possible to use SAC254 as a real-time proxy parameter for estimating the extent of faecal pollution after establishing specific spring and event-type calibrations that take into consideration the variability of the occurrence and the transferability of faecal material It should be highlighted that diffuse faecal pollution from wildlife and live stock sources was responsible for spring water contamination at the investigated catchments. In this respect, the SAC254 can also provide useful information to support microbial source tracking efforts where different situations of infiltration have to be investigated.


Assuntos
Monitoramento Ambiental/métodos , Escherichia coli/isolamento & purificação , Fezes/microbiologia , Água Doce/microbiologia , Microbiologia da Água , Poluição da Água/análise , Absorção , Altitude , Áustria , Contagem de Colônia Microbiana , Monitoramento Ambiental/estatística & dados numéricos , Inundações , Água Doce/análise , Hidrodinâmica , Estações do Ano , Fatores de Tempo , Microbiologia da Água/normas , Abastecimento de Água/normas
2.
Water Sci Technol ; 58(4): 899-909, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18776628

RESUMO

Data communication via Low-Earth-Orbit (LEO) Satellites between portable hydrometeorological measuring stations is the backbone of our system. This networking allows automated event sampling with short time increments also for E. coli field analysis. All activities of the course of the event-sampling can be observed on an internet platform based on a Linux-Server. Conventionally taken samples compared with the auto-sampling procedure revealed corresponding results and were in agreement with the ISO 9308-1 reference method. E. coli concentrations were individually corrected by event specific inactivation coefficients (0.10-0.14 day(-1)), compensating losses due to sample storage at spring temperature in the auto sampler.Two large summer events in 2005/2006 at an important alpine karst spring (LKAS2) were monitored including detailed analysis of E. coli dynamics (n = 271) together with comprehensive hydrological characterisations. High-resolution time series demonstrated a sudden increase of E. coli concentrations in spring water (approximately 2 log10 units) with a specific time delay after the beginning of the event. Statistical analysis suggested the spectral absorption coefficient measured at 254 nm (SAC254) as an early warning surrogate for real time monitoring of faecal input. Together with the LEO-satellite based system it is a helpful tool for early-warning systems in the field of drinking water protection.


Assuntos
Monitoramento Ambiental/instrumentação , Escherichia coli/isolamento & purificação , Água Doce/microbiologia , Microbiologia da Água , Contagem de Colônia Microbiana , Monitoramento Ambiental/métodos , Escherichia coli/citologia , Reprodutibilidade dos Testes , Abastecimento de Água/análise
3.
Environ Microbiol ; 10(10): 2598-608, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18564182

RESUMO

The impairment of water quality by faecal pollution is a global public health concern. Microbial source tracking methods help to identify faecal sources but the few recent quantitative microbial source tracking applications disregarded catchment hydrology and pollution dynamics. This quantitative microbial source tracking study, conducted in a large karstic spring catchment potentially influenced by humans and ruminant animals, was based on a tiered sampling approach: a 31-month water quality monitoring (Monitoring) covering seasonal hydrological dynamics and an investigation of flood events (Events) as periods of the strongest pollution. The detection of a ruminant-specific and a human-specific faecal Bacteroidetes marker by quantitative real-time PCR was complemented by standard microbiological and on-line hydrological parameters. Both quantitative microbial source tracking markers were detected in spring water during Monitoring and Events, with preponderance of the ruminant-specific marker. Applying multiparametric analysis of all data allowed linking the ruminant-specific marker to general faecal pollution indicators, especially during Events. Up to 80% of the variation of faecal indicator levels during Events could be explained by ruminant-specific marker levels proving the dominance of ruminant faecal sources in the catchment. Furthermore, soil was ruled out as a source of quantitative microbial source tracking markers. This study demonstrates the applicability of quantitative microbial source tracking methods and highlights the prerequisite of considering hydrological catchment dynamics in source tracking study design.


Assuntos
Bacteroidetes/isolamento & purificação , Fezes/microbiologia , Microbiologia da Água , Poluição da Água , Animais , Contagem de Colônia Microbiana , DNA Bacteriano/isolamento & purificação , Monitoramento Ambiental , Humanos , Reação em Cadeia da Polimerase/métodos , Ruminantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...