Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 44(3): 481-4, 493, 2013 May.
Artigo em Chinês | MEDLINE | ID: mdl-23898540

RESUMO

OBJECTIVE: To detect unknown impurities in raw drug material of cefotiam hexetil. METHODS: High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed for the determination of impurities in cefotiam hexetil. Agilent SB-C18 column (150 mm x 2.1 mm i. d. , 3.5 microm particles) was used for chromatographic separations of cofotiam hexetil dissolved in deionized water, with mobile phase consisting of (A) 0.1% formic acid and (B) acetonitrile and timed gradient program T (min)/B (%): 0/3, 5/3, 15/20, 20/40, 30/60, 40/80. The flow rate was set at 0. 3 mL/min with DAD detector wavelength fixed at 254 nm. Electrospray ionization source was applied and operated in positive ion MRM mode. The source voltage was kept at 4 kV and cone voltage was 100 V with the mass range m/z 50-1000. Nitrogen was used as nebulizing gas and the nebulizer pressure was 40 psi. The drying gas temperature was 350 degrees C and the drying gas flow was 10 L/min. Results Unknown impurities of cefotiam hexetil were identified. Substance 1 was delta3-isomer of cefotiam hexetil. The structures of 3 other substances were also determined. CONCLUSION: The method is sensitive, rapid and credible for the analysis of cefotiam hexetil and its related impurities, which can be applied in quality control of cefotiam hexetil.


Assuntos
Cefotiam/análogos & derivados , Cromatografia Líquida de Alta Pressão , Contaminação de Medicamentos , Espectrometria de Massas em Tandem , Cefotiam/química , Contaminação de Medicamentos/prevenção & controle , Controle de Qualidade
2.
Fa Yi Xue Za Zhi ; 28(5): 347-50, 2012 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-23213784

RESUMO

OBJECTIVE: To establish a method for determination of strychnine and brucine in formaldehyde fixed tissue by LC-MS/MS analysis. METHODS: The samples were pretreated with solid phase extraction using SCX cartridges and separated on SB-C18 column with mobile phase 0.1% formic acid : 0.1% formic acid-acetonitrile (75:25). Electrospray ionization (ESI) source was utilized and operated in positive ion mode. Multiple reactions monitoring (MRM) mode was applied. External standard method was applied for quantitation. RESULTS: The chromatographic separation of strychnine and brucine in formaldehyde fixed nephritic and hepatic tissues resulted successfully. The standard curve was linear in the range of 0.002-2.0 microg/g for strychnine and brucine in formaldehyde fixed tissues, and the correlation coefficient was more than 0.996. The limits of detection (LOD) of strychnine and brucine in nephritic tissues were 0.06ng/g and 0.03 ng/g, respectively. The LOD of both chemicals were 0.3 ng/g in hepatic tissues. The extraction recovery rate was more than 74.5%. The precision of intra-day and inter-day were both less than 8.2%. CONCLUSION: Strychnine and brucine can be sensitive to be determined in formaldehyde fixed tissue by LC-MS/MS analysis. It can be applied in the forensic toxicological analysis.


Assuntos
Cromatografia Líquida/métodos , Formaldeído/química , Limite de Detecção , Espectrometria de Massas por Ionização por Electrospray/métodos , Estricnina/análogos & derivados , Toxicologia Forense , Formiatos , Rim/metabolismo , Fígado/metabolismo , Espectrometria de Massas , Estrutura Molecular , Reprodutibilidade dos Testes , Estricnina/análise , Estricnina/química , Espectrometria de Massas em Tandem , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...