Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroophthalmology ; 40(6): 292-296, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27928421

RESUMO

This report is of two cases of asymmetrical papilloedema in patients with asymmetrical intraocular pressures (IOPs). The first patient presented with headaches, transient visual obscurations (TVOs), and elevated IOPs, and was found to have increased intracranial pressure caused by a torcula meningioma. He developed papilloedema after his IOPs were pharmacologically lowered; the papilloedema resolved after the IOP became elevated again after stopping his glaucoma drops, and then again returned as the IOP reduced when the drops were restarted. The second patient with a history of Sturge-Weber syndrome requiring previous left trabeculectomy, presented with left-sided TVOs, photopsia, and pulsatile tinnitus caused by idiopathic intracranial hypertension. Asymmetrical papilloedema was observed, worse in the eye with the lower IOP following trabeculectomy. These cases suggest that asymmetric IOP may be one factor that can influence the development of asymmetric papilloedema. Ophthalmologists finding disc swelling at low normal pressures should ask about symptoms of raised ICP, and neuro-ophthalmologists confronted with asymmetrical disc swelling should routinely measure IOP.

2.
Artigo em Inglês | MEDLINE | ID: mdl-24972389

RESUMO

Detachment of a hydrodissection cannula during a phacoemulsification procedure appeared to produce no adverse sequelae during surgery. Day 1 postoperatively, two nonpenetrating hemorrhagic retinal lesions were identified; there was no evidence of posterior capsular perforation. Day 6 postoperatively, the pupil was temporally peaked by a fine vitreous strand running to the main-port incision in the superotemporal cornea. This was divided with Nd:YAG laser, and argon laser was applied to encircle the two retinal lesions. Postoperative uncorrected visual acuity remained 6/4 at day 1, day 6, and week 4 (3 weeks after laser application) follow-up visits. Surgeons must accept responsibility for confirming the integrity of the cannula and syringe connection before beginning hydrodissection, which can be highly destructive to intracameral structures.


Assuntos
Cateterismo/instrumentação , Falha de Equipamento , Corpos Estranhos no Olho/etiologia , Traumatismos Oculares/etiologia , Facoemulsificação/instrumentação , Hemorragia Retiniana/etiologia , Idoso , Anestesia/métodos , Cateterismo/efeitos adversos , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS