Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 9(3): 297-312, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28111961

RESUMO

AIM: Midazolam is a commonly used marker substrate for the in vivo assessment of CYP3A activity. Reliable pharmacokinetic assessment at sub-pharmacological doses of midazolam requires an ultra-sensitive analytical method. METHODS: A new, ultra-sensitive LC-MS/MS method for the determination of midazolam in human plasma using SPE was developed and fully validated. The lowest limit of quantitation is 0.1 pg/ml with a sample volume of 500 µl. RESULTS/CONCLUSION: The following parameters were validated: sensitivity, assay accuracy and precision, linearity, selectivity, and stability of midazolam at pertinent analytical and storage conditions. The validated method was utilized successfully for the sample assay during a midazolam microdosing study for the evaluation of CYP3A4 activity of a clinical candidate.


Assuntos
Cromatografia Líquida/métodos , Midazolam/sangue , Espectrometria de Massas em Tandem/métodos , Estabilidade de Medicamentos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Artigo em Inglês | MEDLINE | ID: mdl-24927417

RESUMO

CTP-499 is a novel oral multi-subtype selective inhibitor of PDEs that is currently in clinical testing, in combination with angiotensin modulators, as a potentially first-in-class treatment for diabetic kidney disease. The compound was discovered and developed by using Concert's proprietary DCE Platform(®) in which deuterium was incorporated at select positions of 1-((S)-5-hydroxyhexyl)-3,7-dimethylxanthine (HDX). CTP-499 metabolizes to five major metabolites: C-21256, D-M2, D-M3, D-M4 and M5, of which all contains deuterium except M5. During in vivo metabolism, however, H/D exchange takes place. As a result, each analyte, except M5, has multiple molecular masses. To accurately quantify the analytes, we developed an LC-MS/MS method focusing on the core structures of the molecules, termed "core-structure analyses". The core-structure analyses method was then validated under GLP guidance in dog, rat and rabbit plasma, with a sample volume of 50 µL. Results demonstrated that this approach accurately quantifies each of the six analytes despite partial exchange of deuterium with hydrogen atoms in the in vivo samples. The validation parameters included accuracy, precision, sensitivity, stability, dilution integrity, hemolysis, matrix effect, selectivity, and recovery. Acceptable intra-run and inter-run assay precision (%CV ≤ 5.5%) and accuracy (90.1-106.7%) were achieved over a linear range of 10-5,000 ng/mL of each analyte. Various stability tests, including bench-top, freeze/thaw, stock solution, and long-term storage, were also performed. All stability results met acceptance criteria. The robustness of the methods was demonstrated by the incurred sample reproducibility (ISR) tests. After validation, the method was successfully used in support of multiple toxicological studies of CTP-499.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Pentoxifilina/análogos & derivados , Pentoxifilina/sangue , Inibidores de Fosfodiesterase/análise , Inibidores de Fosfodiesterase/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Nefropatias Diabéticas/tratamento farmacológico , Cães , Limite de Detecção , Pentoxifilina/metabolismo , Inibidores de Fosfodiesterase/metabolismo , Coelhos , Ratos , Reprodutibilidade dos Testes
3.
Artigo em Inglês | MEDLINE | ID: mdl-23523878

RESUMO

Leukotriene B4 (LTB4) is an important inflammatory component in a number of diseases and has been used as a pharmacodynamic (PD) biomarker. In this report, a highly sensitive and selective ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method for the determination of LTB4 in plasma from ex vivo stimulated human blood, using leukotriene B4-d4 (LTB4-d4, contains four deuterium atoms at the 6, 7, 14, and 15 positions) as the internal standard (IS), was developed and validated. The chromatographic separation of LTB4 from its three isomers and an unknown interference peak from human plasma was crucial to achieve accurate determination of 0.2 ng/mL (LLOQ) of LTB4. LTB4 and the IS were extracted with methyl tertiary butyl ether (MTBE) from 200 µL human plasma. Reversed-phase HPLC separation was carried out with a Phenomenex Synergi Hydro-RP column (100mm×3mm, 2.5 µm). MS/MS detection was set at mass transitions of 335.0→194.9 m/z for LTB4 and 339.0→196.9 m/z for LTB4-d4 in Turbo Ionization Spray (TIS) negative mode. The dynamic range of the method is 0.2-200 ng/mL. LTB4 was found to be stable in human plasma for at least three freeze (-20 °C)/thaw cycles, and on the benchtop (room temperature) for at least 6h. The stock solution storage stability study demonstrated that the LTB4 stock solution, in 50:50 acetonitrile:water, was stable at 4 °C for at least 198 days. The processed samples were found to be stable for at least 72 h at room temperature. The long-term sample storage stability test demonstrated that LTB4 human plasma samples were stable at a storage temperature of -20 °C for at least 198 days. In addition, intraday and interday accuracy and precision, sensitivity, linearity, and recovery were evaluated. An additional partial validation was conducted to decrease the plasma sample volume from 200 to 100 µL. All the data reported in this study fulfilled the requirements and recommendations in the FDA guidance for bioanalytical method validation. Comparison of the validated UFLC-MS/MS method with an ELISA method using ex vivo stimulated samples indicated that although results from the two assays correlated relatively well, the UFLC-MS/MS method has been shown to be superior in selectivity and dynamic range to an ELISA method in our study. The validated UFLC-MS/MS method was successfully used to analyze samples generated from two clinical studies. The excellent assay performance and incurred sample reproducibility (ISR) results obtained from the study sample analysis demonstrated the assay is robust and reliable.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Leucotrieno B4/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia de Fase Reversa/métodos , Humanos , Leucotrieno B4/química , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Biomed Chromatogr ; 26(10): 1163-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22213213

RESUMO

Metformin is a well-known oral antihyperglycemic drug used in treatment of type II diabetes. Analysis of metformin in biological fluids is a challenge owing to its high polarity and small molecular size, which lead to poor retention of metformin on reversed-phase liquid chromatographic columns. A high-throughput method was developed and validated for the determination of metformin in rat plasma in support of preclinical toxicology studies, using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC-MS/MS) and Tecan automated sample preparation. Extracted samples were directly injected onto the unbounded silica column with an aqueous-organic mobile phase. This HILIC-MS/MS method was validated for accuracy, precision, sensitivity, stability, matrix effect, recovery and calibration range. Acceptable intra-run and inter-run assay precision (coefficient of variation ≤ 3.9%) and accuracy (99.0-101.8%) were achieved over a linear range of 50-50,000 ng/mL. Metformin is stable in rat plasma for at least 6 h at room temperature, 147 days at -70°C and through three freeze (-70°C) and thaw cycles. Metformin is also stable in rat whole blood for at least 2 h at room temperature and in an ice-water bath. The validated method was successfully used in support of several preclinical studies where metformin is dosed together with an investigational drug substance. The ruggedness of the validated method was demonstrated by the incurred sample reproducibility test.


Assuntos
Cromatografia Líquida/métodos , Metformina/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida/instrumentação , Estabilidade de Medicamentos , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Interações Hidrofóbicas e Hidrofílicas , Modelos Lineares , Metformina/química , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(15-16): 1169-77, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20378422

RESUMO

Drug-drug interactions involving cytochrome P450 (CYP450s) are an important factor for evaluation of a new chemical entity (NCE) in drug development. To evaluate the potential inhibitory effects of a NCE on the pharmacokinetics of a cocktail of representative probes of CYP enzymes (midazolam for CYP3A4, tolbutamide for CYP2C9, omeprazole for CYP2C19 and dextromethorphan for CYP2D6) and the safety and tolerability of the NCE in the presence of probe substrates, a high throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of tolbutamide, omeprazole, midazolam and dextromethorphan in human plasma using tolbutamide-d(9), midazolam-d(4), (+/-)-omeprazole-d(3), and dextromethorphan-d(3) as the internal standards (ISs). Human plasma samples of 50 microL were extracted by a simple protein-precipitation procedure and analyzed using a high performance liquid chromatography electrospray tandem mass spectrometer system. Reversed-phase HPLC separation was achieved with a Hypersil GOLD AQ column (50 mm x 4.6 mm, 5 microm). MS/MS detection was set at mass transitions of 271-->172 m/z for tolbutamide, 346-->198 m/z for omeprazole, 326-->291 m/z for midazolam, 272-->171 m/z for dextromethorphan, 280-->172 m/z for tolbutamide-d(9) (IS), 349-->198 m/z for (+/-)-omeprazole-d(3) (IS), 330-->295 m/z for midazolam-d(4) (IS), and 275-->171 m/z for dextromethorphan-d(3) (IS) in positive mode. The high throughput LC-MS/MS method was validated for accuracy, precision, sensitivity, stability, recovery, matrix effects, and calibration range. Acceptable intra-run and inter-run assay precision (<10%) and accuracy (<10%) were achieved over a linear range of 50-50,000 ng/mL for tolbutamide, 1-1000 ng/mL for omeprazole, 0.1-100 ng/mL for midazolam and 0.05-50 ng/mL for dextromethorphan in human plasma. Method robustness was demonstrated by the 100% pass rate of 24 incurred sample analysis runs and all of the 50 clinical study samples used for incurred sample reproducibility (ISR) test having met the acceptance criterion (%Diff within 20%). The overall ISR results for all compounds showed that over 95% of the samples had a %Diff of less than 10%. The method is simple, rapid and rugged, and has been applied successfully to sample analysis in support of a drug-drug interaction study.


Assuntos
Cromatografia Líquida/métodos , Dextrometorfano/sangue , Midazolam/sangue , Omeprazol/sangue , Espectrometria de Massas em Tandem/métodos , Tolbutamida/sangue , Sistema Enzimático do Citocromo P-450/química , Sistema Enzimático do Citocromo P-450/metabolismo , Dextrometorfano/química , Dextrometorfano/farmacologia , Descoberta de Drogas , Interações Medicamentosas , Estabilidade de Medicamentos , Ensaios de Triagem em Larga Escala , Humanos , Midazolam/química , Midazolam/farmacologia , Omeprazol/química , Omeprazol/farmacologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Tolbutamida/química , Tolbutamida/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...