Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin Lab ; 69(2)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36787551

RESUMO

BACKGROUND: Our aim was to evaluate the cutoff values of RHE and MRV as markers to diagnose IDA in healthy Han ethnic adults of Chengdu. METHODS: A total of 263 Han adults who needed bone marrow aspiration for diagnosis were enrolled according to the inclusive and exclusive criteria. The cutoff values of RHE and MRV were determined by receiver operating curves. RESULTS: According to statistical analysis, the cutoff values of RHE and MRV in male and female groups were 26.75 pg, 89.60 fL and 26.65 pg, 88.55 fL respectively. The areas under the curve (AUC) of RHE and MRV were 0.941, 0.939 and 0.925, 0.909 in male and female groups, respectively. CONCLUSIONS: In our study, we explored the cutoff values of RHE and MRV to diagnose IDA in the Han ethnic population in Chengdu for the first time.


Assuntos
Anemia Ferropriva , Adulto , Feminino , Humanos , Masculino , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/epidemiologia , Área Sob a Curva , População do Leste Asiático , Índices de Eritrócitos
2.
Braz J Med Biol Res ; 55: e12320, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36383803

RESUMO

This study explored the correlation between interleukins (IL)-12, IL-18, and IL-21 and the viral load in patients with chronic hepatitis B virus (HBV). A total of 142 patients were consecutively enrolled. All were hepatitis B surface antigen (HBsAg)-positive for >6 months and did not receive drug therapy. An ELISA kit was used to test the IL-12, IL-18, IL-21, and acetylcholinesterase (AchE) levels in serum samples from chronic HBV patients and healthy control groups. The amounts of IL-12 and IL-18 were highest in the 5-6log10 (high viral load) group, while IL-21 was highest in the 3-4log10 (low viral load) group. Also, the IL-21 amount was decreased in the HBsAg+/HBeAg/HBcAb+ group, and IL-12, IL-18, and IL-21 were decreased in the normal alanine aminotransferase (ALT) group compared to the abnormal ALT group. These data suggested that IL-12, IL-18, and IL-21 serum levels were positively correlated with disease progression and could reflect disease severity for different HBV-DNA loads. Detection of IL-12, IL-18, and IL-21 levels was found to be helpful for evaluating the degree of liver cell damage and predicting the progression of hepatitis.


Assuntos
Hepatite B Crônica , Interleucinas , Carga Viral , Humanos , Acetilcolinesterase , Alanina Transaminase , DNA Viral , Antígenos de Superfície da Hepatite B/uso terapêutico , Vírus da Hepatite B/genética , Hepatite B Crônica/diagnóstico , Interleucina-12/sangue , Interleucina-18/sangue , Interleucinas/sangue
3.
Braz. j. med. biol. res ; 55: e12320, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403901

RESUMO

This study explored the correlation between interleukins (IL)-12, IL-18, and IL-21 and the viral load in patients with chronic hepatitis B virus (HBV). A total of 142 patients were consecutively enrolled. All were hepatitis B surface antigen (HBsAg)-positive for >6 months and did not receive drug therapy. An ELISA kit was used to test the IL-12, IL-18, IL-21, and acetylcholinesterase (AchE) levels in serum samples from chronic HBV patients and healthy control groups. The amounts of IL-12 and IL-18 were highest in the 5-6log10 (high viral load) group, while IL-21 was highest in the 3-4log10 (low viral load) group. Also, the IL-21 amount was decreased in the HBsAg+/HBeAg/HBcAb+ group, and IL-12, IL-18, and IL-21 were decreased in the normal alanine aminotransferase (ALT) group compared to the abnormal ALT group. These data suggested that IL-12, IL-18, and IL-21 serum levels were positively correlated with disease progression and could reflect disease severity for different HBV-DNA loads. Detection of IL-12, IL-18, and IL-21 levels was found to be helpful for evaluating the degree of liver cell damage and predicting the progression of hepatitis.

4.
Clin Lab ; 66(9)2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32902211

RESUMO

BACKGROUND: The goals of this study are to determine the RIs of RHE, MRV, and reticulocyte count percentage (RET) in healthy Han ethnic adults of Chengdu. METHODS: A total of 691 Han adults without iron deficiency, aged 20 to 90 years were included in the study. The RIs were defined as mean ± 1.96 SD. RESULTS: After statistical analysis the RIs were 29.95 - 35.12 pg (RHE), 99.76 - 115.97 fL (MRV) in males and 29.77 - 34.52 pg (RHE), 98.72 - 113.83 fL (MRV) in females. RET reference interval was 0.485 - 1.504%. CONCLUSIONS: In our study, we established RHE, MRV, and RET RIs of the Han ethnic population in Chengdu for the first time.


Assuntos
Anemia Ferropriva , Reticulócitos , Adulto , Etnicidade , Feminino , Hemoglobinas/análise , Humanos , Masculino , Valores de Referência , Contagem de Reticulócitos , Reticulócitos/química
5.
Clin Lab ; 65(8)2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31414742

RESUMO

BACKGROUND: In order to establish suitable reference intervals (RIs) of serum cytokeratin-19 fragment (Cyfra211) and neuron specific enolase (NSE) for the healthy Chinese population in Chengdu, China, an indirect method was developed using the data from the people presented for routine health check-up. METHODS: All results for 4,988 healthy persons serum cytokeratin-19 fragment and 3,293 healthy persons neuron specific enolase were collected in our laboratory information system between January 2016 and December 2018. Outliers were identified and excluded using the stem-and-leaf and box plot methods. Mann-Whitney U test was used to observe the difference between sexes. Spearman's rank correlation analysis was used to evaluate the correlation between serum results and age. The RIs were defined by nonparametric 95th percentile interval. RESULTS: After statistical analysis the indirect RIs were 0.0 - 3.70 ng/mL (Cyfra211) and 0 - 17.26 ng/mL (NSE) in males and 0.0 - 3.35 ng/mL (Cyfra211) and 0.0 - 16.29 ng/mL (NSE) in females. Cyfra211 and NSE levels in males and females had no correlation with age. Therefore, there was no need to establish RIs according to age group. RIs of Cyfra211 and NSE were verified and passed the verification in the end. CONCLUSIONS: Using health check-up persons' laboratory data values is a relatively easy and cheap method of establishing laboratory specific references. This method deserves to be promoted and applied by other clinical laboratories.


Assuntos
Antígenos de Neoplasias/sangue , Técnicas de Laboratório Clínico/métodos , Nível de Saúde , Queratina-19/sangue , Fosfopiruvato Hidratase/sangue , Vigilância da População/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
6.
Forensic Sci Int ; 207(1-3): 177-82, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21035284

RESUMO

A novel disposable amperometric biosensor strip for determination of blood alcohol concentration (BAC) with small volume of sample has been constructed using screen-printed electrodes (SPE), nanocomposite film and alcohol dehydrogenase (ADH). Firstly, the GNPs-MWCNT-Nafion nanocomposite film modified on a working electrode was made of Nafion-117, multi-wall carbon nanotubes (MWCNT) and gold nanoparticles (GNPs). After that Meldola's blue (MB) acted as an electron transfer mediator and the mixed solution of ADH, nicotinamide adenine dinucleotide (NAD(+)) were modified in order on the nanocomposite film. At last, a hydrophilic membrane which had an eyehole in center was placed at the outermost of the working area to make a reaction tank of 5 µL, then the hydrophilic membrane/ADH-NAD(+)/GNPs-MWCNT-MB-Nafion/SPE was prepared. The detection of BAC can be accomplished with 5 µL of blood sample obtained precisely by siphonage. Optimum conditions of the biosensor were experimentally determined by varying several important parameters: working potential, solution pH value, environmental temperature and interferences. Experimental results indicated that the biosensor possessed a good accuracy and stability, the linear response range was 2.0 × 10(-4) to 25 × 10(-3)mol/L and the detection limit of the biosensor was 5.0 × 10(-5)mol/L (S/N=3). In the measurement of blood samples, the proposed biosensor had excellent detection performance for measuring BAC and showed a good correlation with gas chromatography. The prepared biosensor strip can be valid for the analysis of BAC.


Assuntos
Técnicas Biossensoriais/instrumentação , Depressores do Sistema Nervoso Central/sangue , Equipamentos Descartáveis , Etanol/sangue , Álcool Desidrogenase , Toxicologia Forense/instrumentação , Toxicologia Forense/métodos , Ouro , Humanos , Indicadores e Reagentes , Nanopartículas Metálicas , NAD , Nanocompostos , Nanotubos de Carbono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...