Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(20)2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37696272

RESUMO

Objective.Metal artifact reduction (MAR) has been a key issue in CT imaging. Recently, MAR methods based on deep learning have achieved promising results. However, when deploying deep learning-based MAR in real-world clinical scenarios, two prominent challenges arise. One limitation is the lack of paired training data in real applications, which limits the practicality of supervised methods. Another limitation is that image-domain methods suitable for more application scenarios are inadequate in performance while end-to-end approaches with better performance are only applicable to fan-beam CT due to large memory consumption.Approach.We propose a novel image-domain MAR method based on the generative adversarial network with variable constraints (MARGANVAC) to improve MAR performance. The proposed variable constraint is a kind of time-varying cost function that can relax the fidelity constraint at the beginning and gradually strengthen the fidelity constraint as the training progresses. To better deploy our image-domain supervised method into practical scenarios, we develop a transfer method to mimic the real metal artifacts by first extracting the real metal traces and then adding them to artifact-free images to generate paired training data.Main results.The effectiveness of the proposed method is validated in simulated fan-beam experiments and real cone-beam experiments. All quantitative and qualitative results demonstrate that the proposed method achieves superior performance compared with the competing methods.Significance.The MARGANVAC model proposed in this paper is an image-domain model that can be conveniently applied to various scenarios such as fan beam and cone beam CT. At the same time, its performance is on par with the cutting-edge dual-domain MAR approaches. In addition, the metal artifact transfer method proposed in this paper can easily generate paired data with real artifact features, which can be better used for model training in real scenarios.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico , Algoritmos , Metais , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...