Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 16(26): 33404-33415, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38904481

RESUMO

Triboelectric nanogenerators (TENGs) have garnered substantial attention in breeze wind energy harvesting. However, how to improve the output performance and reduce friction and wear remain challenging. To this end, a blade-type triboelectric-electromagnetic hybrid generator (BT-TEHG) with a double frequency up-conversion (DFUC) mechanism is proposed. The DFUC mechanism enables the TENG to output a high-frequency response that is 15.9 to 300 times higher than the excitation frequency of 10 to 200 rpm. Coupled with the collisions between tribomaterials, a higher surface charge density and better generating performance are achieved. The magnetization direction and dimensional parameters of the BT-TEHG were optimized, and its generating characteristics under varying rotational speeds and electrical boundary conditions were studied. At wind speeds of 2.2 and 10 m/s, the BT-TEHG can generate, respectively, power of 1.30 and 19.01 mW. Further experimentation demonstrates its capacity to charge capacitors, light up light emitting diodes (LEDs), and power wireless temperature and humidity sensors. The demonstrations show that the BT-TEHG has great potential applications in self-powered wireless sensor networks (WSNs) for environmental monitoring of intelligent agriculture.

2.
Sci Adv ; 7(34)2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34417171

RESUMO

Soft robotics revolutionized human-robot interactions, yet there exist persistent challenges for developing high-performance soft actuators that are powerful, rapid, controllable, safe, and portable. Here, we introduce a class of self-contained soft electrofluidic actuators (SEFAs), which can directly convert electrical energy into the mechanical energy of the actuators through electrically responsive fluids that drive the outside elastomer deformation. The use of special dielectric liquid enhances fluid flow capabilities, improving the actuation performance of the SEFAs. SEFAs are easily manufactured by using widely available materials and common fabrication techniques, and display excellent comprehensive performances in portability, controllability, rapid response, versatility, safety, and actuation. An artificial muscle stretching a joint and a soft bionic ray swimming in a tank demonstrate their effective performance. Hence, SEFAs offer a platform for developing soft actuators with potential applications in wearable assistant devices and soft robots.

3.
Phys Fluids (1994) ; 33(3): 031301, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33897237

RESUMO

The outbreak of the coronavirus disease has drawn public attention to the transmission of infectious pathogens, and as major carriers of those pathogens, respiratory droplets play an important role in the process of transmission. This Review describes respiratory droplets from a physical and mechanical perspective, especially their correlation with the transmission of infectious pathogens. It covers the important aspects of (i) the generation and expulsion of droplets during respiratory activities, (ii) the transport and evolution of respiratory droplets in the ambient environment, and (iii) the inhalation and deposition of droplets in the human respiratory tract. State-of-the-art experimental, computational, and theoretical models and results are presented, and the corresponding knowledge gaps are identified. This Review stresses the multidisciplinary nature of its subject and appeals for collaboration among different fields to fight the present pandemic.

4.
Sensors (Basel) ; 19(14)2019 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-31330800

RESUMO

The approach to improve the output power of piezoelectric energy harvester is one of the current research hotspots. In the case where some sources have two or more discrete vibration frequencies, this paper proposed three types of magnetically coupled multi-frequency hybrid energy harvesters (MHEHs) to capture vibration energy composed of two discrete frequencies. Electromechanical coupling models were established to analyze the magnetic forces, and to evaluate the power generation characteristics, which were verified by the experimental test. The optimal structure was selected through the comparison. With 2 m/s2 excitation acceleration, the optimal peak output power was 2.96 mW at 23.6 Hz and 4.76 mW at 32.8 Hz, respectively. The superiority of hybrid energy harvesting mechanism was demonstrated. The influences of initial center-to-center distances between two magnets and length of cantilever beam on output power were also studied. At last, the frequency sweep test was conducted. Both theoretical and experimental analyses indicated that the proposed MHEH produced more electric power over a larger operating bandwidth.

5.
J Healthc Eng ; 2019: 8065920, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31281617

RESUMO

Hydrodynamically levitated rotary blood pumps (RBPs) with noncontact bearing are effective to enhance the blood compatibility. The spiral groove bearing (SGB) is one of the key components which offer the suspension force to the RBP. Current studies focus on the suspension performance of the SGB under continuous flow condition. However, the RBP shows pulsatile characteristics in the actual clinical application, which may affect the suspension performance of the SGB. In this paper, the impact of pulsatile flow upon the suspension force from the SGB is studied. A model of the SGB with a groove formed of wedge-shaped spirals is built. Then, the CFD calculation of the hydrodynamic force offered by designed SGB under simulated pulsatile flow is introduced to obtain the pulsatile performance of the suspension force. The proposed method was validated by experiments measuring the hydrodynamic force with different bearing gaps. The results show that the suspension force of the SGB under pulsate flow is the same as under steady flow with equivalent effective pressure. This paper provides a method for suspension performance test of the SGB.


Assuntos
Coração Auxiliar , Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Desenho de Equipamento , Humanos , Hidrodinâmica , Fenômenos Mecânicos
6.
Materials (Basel) ; 12(5)2019 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-30857349

RESUMO

It is well known that three-dimensional (3D) printing is an emerging technology used to produce customized implants and surface characteristics of implants, strongly deciding their osseointegration ability. In this study, Ti alloy microspheres were printed under selected rational printing parameters in order to tailor the surface micro-characteristics of the printed implants during additive manufacturing by an in situ, controlled way. The laser path and hatching space were responsible for the appearance of the stripy structure (S), while the bulbous structure (B) and bulbous⁻stripy composite surface (BS) were determined by contour scanning. A nano-sized structure could be superposed by hydrothermal treatment. The cytocompatibility was evaluated by culturing Mouse calvaria-derived preosteoblastic cells (MC3T3-E1). The results showed that three typical microstructured surfaces, S, B, and BS, could be achieved by varying the 3D printing parameters. Moreover, the osteogenic differentiation potential of the S, B, and BS surfaces could be significantly enhanced, and the addition of nano-sized structures could be further improved. The BS surface with nano-sized structure demonstrated the optimum osteogenic differentiation potential. The present research demonstrated an in situ, controlled way to tailor and optimize the surface structures in micro-size during the 3D printing process for an implant with higher osseointegration ability.

7.
Sensors (Basel) ; 18(12)2018 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-30563059

RESUMO

This paper proposes and investigates a piezoelectric energy harvesting system based on the flow induced vibration of a piezoelectric composite cantilever pipe. Dynamic equations for the proposed energy harvester are derived considering the fluid-structure interaction and piezoelectric coupling vibration. Linear global stability analysis of the fluid-solid-electric coupled system is done using the numerical continuation method to find the neutrally stable vibration mode of the system. A measure of the energy harvesting efficiency of the system is proposed and analyzed. A series of simulations are conducted to throw light upon the influences of mass ratio, dimensionless electromechanical coupling, and dimensionless connected resistance upon the critical reduced velocity and the normalized energy harvesting efficiency. The results provide useful guidelines for the practical design of piezoelectric energy harvester based on fluid structure interaction and indicate some future topics to be investigated to optimize the device performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...