1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(4): 971-4, 2015 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-26197585

RESUMO

A cavity ring-down spectrometer (CRDS) was built based on telecom distributed feedback (DFB) diode lasers. The ring down cavity was formed by mirrors of 99. 997% reflectivity with a separation of 130 cm, with an empty ring down time of about 150 µs. A minimum detectable absorption coefficient of 5 x 10(-12) cm(-1) was obtained by averaging about 1,000 recorded spectra. The ring down cavity is thermo-isolated, and used as an interferometer to calibrate the recorded spectrum. A feedback control scheme was applied to step scan the laser frequency, successively matching each of the longitudinal modes of the cavity. By measuring the CO contents in a standard gas sample, the quantitative capability of the CRDS instrument was demonstrated, and a CO detection limit of 4 ppb was achieved. The instrument was applied to monitor the CO concentration in ambient air.

2.
Appl Opt ; 53(32): 7716-23, 2014 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-25402995

RESUMO

A cavity ring-down spectrometer is built for trace gas detection using telecom distributed feedback (DFB) diode lasers. The longitudinal modes of the ring-down cavity are used as frequency markers without active-locking either the laser or the high-finesse cavity. A control scheme is applied to scan the DFB laser frequency, matching the cavity modes one by one in sequence and resulting in a correct index at each recorded spectral data point, which allows us to calibrate the spectrum with a relative frequency precision of 0.06 MHz. Besides the frequency precision of the spectrometer, a sensitivity (noise-equivalent absorption) of 4×10-11 cm-1 Hz-1/2 has also been demonstrated. A minimum detectable absorption coefficient of 5×10-12 cm-1 has been obtained by averaging about 100 spectra recorded in 2  h. The quantitative accuracy is tested by measuring the CO2 concentrations in N2 samples prepared by the gravimetric method, and the relative deviation is less than 0.3%. The trace detection capability is demonstrated by detecting CO2 of ppbv-level concentrations in a high-purity nitrogen gas sample. Simple structure, high sensitivity, and good accuracy make the instrument very suitable for quantitative trace gas analysis.


Assuntos
Gases/análise , Microquímica/instrumentação , Análise Espectral/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade