Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; : 15266028241237465, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528653

RESUMO

INTRODUCTION: Endovascular aneurysm repair using iodinated contrast agents risks contrast-induced nephropathy, especially in high-risk patients. This technical note describes a contrast-free endovascular aneurysm repair (EVAR) protocol using preoperative imaging measurement and fibrin sealant (FS) filling. TECHNIQUE: Preoperative imaging measurement and intraoperative guidewire manipulation facilitated anatomical identification without contrast. After endograft deployment, the aneurysm sac was filled with FS if endoleak was indicated by pressure fluctuations. RESULT: Between 2017 and 2020, 6 high-risk patients underwent contrast-free EVAR with FS filling. Complete exclusion was achieved in all cases. Over follow-up, no endoleaks, deterioration in renal function, or other complications were observed. CONCLUSION: Contrast-free EVAR with FS filling shows early feasibility as an alternative technique for contrast-induced nephropathy (CIN) high-risk patients, while larger studies with long-term monitoring are imperative to validate outcomes. CLINICAL IMPACT: This study showcases a contrast-free EVAR technique with fibrin sealant filling for high-risk CIN patients. It offers a safer approach for those with renal challenges, reducing CIN risk. The technique's feasibility in a small cohort suggests its utility in treating AAA without iodinated contrast, crucial for patients with specific health risks. For clinicians, it introduces a method that decreases nephrotoxic risks, potentially changing practice for vulnerable patients.

2.
J Vasc Access ; : 11297298231225679, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436293

RESUMO

BACKGROUND: Superior Mesenteric Artery (SMA) lesions present a significant challenge in endovascular surgery. Both the transbrachial (TBA) and the transfemoral (TFA) approaches have been employed for the treatment of these lesions, but the comparative effectiveness of these methods remains unclear. MATERIALS AND METHODS: A retrospective analysis was conducted on patients who underwent TBA and TFA at a tertiary center between June 2020 and February 2023. Key parameters including technical success, procedural details, and complication rates were examined. RESULTS: In a study of 99 patients, 66 underwent Transfemoral Approach (TFA) and 33 underwent Transbrachial Approach (TBA). No significant age or gender differences were noted between groups. TFA procedures were longer (90.0 vs 63.5 min, p = 0.002) and had higher fluoroscopy times (59.0 vs 43.0 min, p = 0.02) and selective SMA times (366.0 vs 245.0 min, p = 0.038) compared to TBA, especially with a smaller aortomesenteric angle (<90°). Technical success rates were high in both groups (TFA 97%, TBA 93.9%, p = 0.60). Complication rates were similar between groups, with no significant predictors for access site complications identified. CONCLUSION: Both the TBA and the TFA are effective for the treatment of SMA lesions, with TBA potentially offering advantages in terms of efficiency and patient recovery, particularly in cases with certain anatomy. No significant differences in complication rates were found between the two groups. Further research, including prospective randomized trials, is needed to confirm these findings.

3.
J Endovasc Ther ; : 15266028231182027, 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37415484

RESUMO

BACKGROUND: To assess the feasibility and first-in-human experience of a novel endovascular robotic system for treatment of lower extremity peripheral arterial disease (PAD). METHODS: Between November 2021 and January 2022, consecutive patients with obstructive lower extremity PAD and claudication (Rutherford 2-5) with >50% stenosis demonstrated on angiography were enrolled in this study. Lower extremity peripheral arterial intervention was performed using the endovascular robotic system, which consisted of a bedside unit and an interventional console. The primary endpoints were technical success, defined as the successful manipulation of the lower extremity peripheral arterial devices using the robotic system, and safety. The secondary endpoints were clinical success, defined as 50% residual stenosis at the completion of the robot-assisted procedure without major adverse cardiac events and radiation exposure. RESULTS: In total, 5 patients with PAD were enrolled in this study (69.2±6.0 years; 80% men). The novel endovascular robotic system successfully completed the entire procedure of endovascular treatment of lower extremity PAD. Conversion to manual operation, including advancement, retracement, rotation of the guidewires, catheters, sheaths, deployment, and release of the balloons and stent grafts, was not necessary. We achieved the criteria for clinical procedural and technical success in all patients. No deaths, myocardial infarctions, or ruptures occurred in the period up to 30 days after the procedure, and no device-related complications were observed. The robotic system operator had 97.6% less radiation exposure than that at the procedure table, with a mean of 1.40±0.49 µGy. CONCLUSIONS: This study demonstrated the safety and feasibility of the robotic system. The procedure reached technical and clinical performance metrics and resulted in significantly lower radiation exposure to the operators at the console compared with that at the procedure table. CLINICAL IMPACT: There were some reports about several robotic systems used in the peripheral arterial disease, but no robotic system was able to perform entire procedure of endovascular treatment of lower extremity peripheral arterial disease (PAD).To solve this problem, we designed a remote-control novel endovascular robotic system. It was the first robotic system that can perform entire procedure of endovascular treatment of PAD worldwide. A novelty retrieval report about this is provided in the supplementary materials.The robotic system is compatible with all commercial endovascular surgical devices currently available in the market, including guidewires, catheters and stent delivery systems. It can perform all types of motion, such as forward, backward, and rotation to meet the requirements of all types of endovascular procedures. During the operation, the robotic system can perform these operations in a fine-tuned manner, so it is easy to cross the lesions, which is the key factor influencing the success rate of the operation. In addition, the robotic system can effectively reduce the exposure time to radiation, thereby reducing the risk of occupational injury.

4.
Eur Radiol ; 33(11): 7408-7418, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37338556

RESUMO

OBJECTIVES: To assess the practicability and safety of a novel endovascular robotic system for performing endovascular aortic repair in human. METHODS: A prospective observational study was conducted in 2021 with 6 months post-operative follow-up. Patients with aortic aneurysms and clinical indications for elective endovascular aortic repair were enrolled in the study. The novel developed robotic system is applicable for the majority of commercial devices and various types of endovascular surgeries. The primary endpoint was technical success without in-hospital major adverse events. Technical success was defined as the ability of the robotic system to complete all procedural steps based on procedural segments. RESULTS: The first-in-human evaluation of robot-assisted endovascular aortic repair was performed in five patients. The primary endpoint was achieved in all patients (100%). There were no device- or procedure-related complications or no in-hospital major adverse events. The operation time and total blood loss in these cases were equal to those in the manual procedures. The radiation exposure of the surgeon was 96.5% lower than that in the traditional position while the radiation exposure of the patients was not significantly increased. CONCLUSIONS: Early clinical evaluation of the novel endovascular aortic repair in endovascular aortic repair demonstrated practicability, safety, and procedural effectiveness comparable to manual operation. In addition, the total radiation exposure of the operator was significantly lower than that of traditional procedures. CLINICAL RELEVANCE STATEMENT: This study applies a novel approach to perform the endovascular aortic repair in a more accurate and minimal-invasive way and lays the foundation for the perspective automation of the endovascular robotic system, which reflects a new paradigm for endovascular surgery. KEY POINTS: • This study is a first-in-human evaluation of a novel endovascular robotic system for endovascular aortic repair (EVAR). • Our system might reduce the occupational risks associated with manual EVAR and contribute to achieving a higher degree of precision and control. • Early evaluation of the endovascular robotic system demonstrated practicability, safety, and procedural effectiveness comparable to that of manual operation.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Procedimentos Cirúrgicos Robóticos , Humanos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Estudos Prospectivos , Resultado do Tratamento , Implante de Prótese Vascular/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco
5.
Front Cardiovasc Med ; 10: 1034354, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910538

RESUMO

Background: Thoracic endovascular aortic repair, initially intended for thoracic aortic disease treatment, has extended its application to the proximal zone of the aorta. However, the safety and surgical outcomes of extending the proximal landing zone into the ascending aorta (zone 0) in selected cases remain unknown. Thus, we performed a systematic review and meta-analysis of zone 0 thoracic endovascular aortic repair (TEVAR) to obtain a deeper understanding of its safety, outcomes, and trends over time. Methods: A literature search was performed using PubMed, EMBASE, and Web of Science databases in accordance with the preferred reporting items for systematic reviews and meta-analyses guidelines, from January, 1997 to January, 2022. Only studies involving zone 0 TEVAR were included. The retrieved data from the eligible studies included basic study characteristics, 30-day/in-hospital mortality rate, indications, comorbidities, stent grafts, techniques, and complications. Summary effect measures of the primary outcomes were obtained by logarithmically pooling the data with an inverse variance-weighted fixed-effects model. Results: Fifty-three studies with 1,013 patients were eligible for analysis. The pooled 30-day/in-hospital mortality rate of zone 0 TEVAR was 7.49%. The rates of post-operative stroke, type Ia endoleak, retrograde type A aortic dissection, and spinal cord ischemia were 8.95, 9.01, 5.72, and 4.12%, respectively. Conclusions: Although many novel stent grafts and techniques targeting zone 0 TEVAR are being investigated, a consensus on technique and device selection in zone 0 TEVAR is yet to be established in current practice. Furthermore, the post-operative stroke rate is relatively high, while other complication rates and perioperative death rate are comparable to those of TEVAR for other aortic zones.

6.
J Endovasc Ther ; : 15266028221108903, 2022 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-35786082

RESUMO

OBJECTIVES: This study evaluated the feasibility and safety of zone 1 thoracic endovascular aortic repair (TEVAR) with fenestrated surgeon-modified stent-graft (SMSG) for aortic arch pathologies. METHODS: Between March 2016 and November 2020, 34 consecutive patients underwent zone 1 TEVAR with fenestrated SMSG for aortic arch pathologies. Outcomes included technical success, perioperative, and follow-up morbidity and mortality. RESULTS: During the study period, 34 patients were treated with zone 1 TEVAR with fenestrated SMSG. Twenty-four (70.6%) patients presented with type B aortic dissections, 9 (26.5%) patients presented with aneurysms (7 located on the lesser curvature side of aortic arch), 1 (2.9%) patient presented with type Ia endoleak after previous TEVAR owing to traumatic aortic dissection. The proximal landing zone for all patients were in zone 1, and all supra-aortic trunks were reconstructed, except for one left subclavian artery. Technical success was achieved in all cases. The 30-day estimated survival (±SE) was 90.9% ± 5.0% [95% confidence interval (CI): 77.0%-97.0%]. The 30-day estimated freedom from reintervention (±SE) was 87.9% ± 5.7% (95% CI: 73.4%-95.3%). At a median follow-up of 48 months (range, 12-68 months), 2 patients died, including 1 aortic-related death and 1 non-aortic-related death. One patient had reintervention 13 months after the operation owing to type Ia endoleak. All supra-aortic trunks were patent. The estimated survival (±SE) during follow-up was 85.1% ± 6.2% (95% CI: 69.9%-93.6%). One (2.7%) patient had stroke. The estimated freedom from reintervention (±SE) during follow-up was 84.2% ± 6.5% (95% CI: 69.9%-93.5%). CONCLUSIONS: Zone 1 TEVAR with fenestrated SMSG is an alternate option for treatment of aortic arch pathologies in experienced centers.

7.
Front Cardiovasc Med ; 9: 843551, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35463748

RESUMO

Objective: Type A aortic dissection (TAAD) is associated with high morbidity and mortality, and open surgery is the best treatment option. Development of endovascular repair devices for TAAD will benefit patients deemed unfit for open surgery. In this study, we performed a thorough investigation of anatomical features in Asian patients with TAAD to learn about the patient eligibility of a novel ascending aortic endograft technique. Methods: Computed tomography angiography (CTA) images of TAAD cases in our institution from January 2015 to November 2021 were reviewed, and three-dimensional reconstructions were performed with the Endosize software (Therenva, Rennes, France). Anatomic structures including length measured along centerline and greater/lesser curvature, ascending aorta/aortic root dimensions, as well as location of entry tear and extent of dissection were analyzed. Results: A total of 158 patients were included [median age 58 years, interquartile range (IQR), 30-76 years; 115 males, 72.8%]. In 99 (62.7%) of the cases, entry tear was distal to the sinotubular junction (STJ). In 106 (67.1%) of the cases, the pathology proximally extended into the aortic root, which was intramural hematoma in 37 (23.4%) of the cases, and the aortic root was free from the pathology in 52 (32.9%) of the cases. The median distance from the STJ to the proximal edge of the ostium of the innominate artery (IA) measured along the centerline was 65 mm (IQR 58-74 mm). The median distance from the distal edge of the higher coronary ostium to the STJ was 7.95 mm (IQR 5.625-10.9 mm). The bare metal stent part was set between the edge of the higher coronary ostium and the STJ. In our series, 63 (39.9%) of the cases had this distance >10 mm. The relative difference was <20% between the STJ and the proximal edge of the ostium of the IA in 92 (58.2%) of the cases. Ascending aorta radius of curvature was 52.2 mm (IQR 43.7-63.7 mm). Conclusions: Our study demonstrates that 56.3% of the TAAD cases would be amenable to endovascular repair by the novel ascending aortic endograft, with sufficient landing zone free of the dissected aorta.

8.
Front Cardiovasc Med ; 9: 1031068, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36727027

RESUMO

Objectives: This retrospective analysis aimed to evaluate the early and midterm outcomes of thoracic endovascular aortic repair (TEVAR) with fenestrated surgeon-modified stent-graft (f-SMSG) for type B aortic dissections (TBAD) involving the aortic arch. Methods: From March 2016 to April 2021, 47 consecutive patients were treated using TEVAR with f-SMSG. All patients were diagnosed with TBAD involving the aortic arch. Results: In total, 47 patients with TBAD involving the aortic arch were treated with f-SMSGs. There were 21 zone 1 and 26 zone 2 TEVAR, and 65 arteries were revascularized successfully with fenestrations. Technical success was achieved in 46 patients (97.88%). The 30-day estimated survival (± SE) and reintervention was 93.6 ± 1.0% (95% Confidence Interval [CI], 92.6-94.6%) and 91.5 ± 1.2% (95% CI, 90.3-92.7%), respectively. During a median follow-up of 51 months (range, 16-71 months), 1 patient died of rupture of aortic dissection (AD) and 3 patients died of non-aortic-related reasons. Reintervention was performed for four patients, including two patients of type IA entry flow and two patients of type IB entry flow. No occlusion of the supra-aortic trunk was observed. The estimated survival and reintervention (± SE) at 4 years was 88.7 ± 1.4% (95% CI, 87.3-90.1%) and 84.8 ± 1.5% (95% CI, 83.3-86.3%), respectively. Conclusion: Thoracic endovascular aortic repair with f-SMSG is an alternative treatment option for TBAD involving the aortic arch in high-volume centers.

9.
Sensors (Basel) ; 19(15)2019 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-31382683

RESUMO

Soil organic matter (SOM) is a major indicator of soil fertility and nutrients. In this study, a soil organic matter measuring method based on an artificial olfactory system (AOS) was designed. An array composed of 10 identical gas sensors controlled at different temperatures was used to collect soil gases. From the response curve of each sensor, four features were extracted (maximum value, mean differential coefficient value, response area value, and the transient value at the 20th second). Then, soil organic matter regression prediction models were built based on back-propagation neural network (BPNN), support vector regression (SVR), and partial least squares regression (PLSR). The prediction performance of each model was evaluated using the coefficient of determination (R2), root-mean-square error (RMSE), and the ratio of performance to deviation (RPD). It was found that the R2 values between prediction (from BPNN, SVR, and PLSR) and observation were 0.880, 0.895, and 0.808. RMSEs were 14.916, 14.094, and 18.890, and RPDs were 2.837, 3.003, and 2.240, respectively. SVR had higher prediction ability than BPNN and PLSR and can be used to accurately predict organic matter contents. Thus, our findings offer brand new methods for predicting SOM.


Assuntos
Nariz Eletrônico , Solo/química , Calibragem , Gases/química , Análise dos Mínimos Quadrados , Redes Neurais de Computação , Máquina de Vetores de Suporte/normas , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...