1.
Ultrasound Q ; 40(2): 104-110, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38470974

RESUMO

ABSTRACT: Patients with compensated advanced chronic liver disease (cACLD) can safely spared screening esophagogastroduodenoscopy (EGD) when they meet the Baveno VI criteria as assessed by transient elastography. Recently, the cutoff values of the Baveno VI criteria assessed by 2-dimensional shear wave elastography (2D-SWE) were proposed. We aimed to validate it to rule out high-risk varices (HRVs) in cACLD patients; combine spleen diameter (SPD) with the Baveno VI criteria and assess whether it can spare more screening EGD. A total of 173 cACLD patients with successful liver stiffness (LS) measurements and EGD examinations were included. We analyzed the risk factors that predicted HRVs and compared the performances of different models for ruling out HRVs. The platelet count, LS, and SPD were independent predictors of HRVs. The AUCs of platelet count, LS, spleen stiffness and SPD for diagnosing HRVs were 0.797, 0.757, 0.834, and 0.804, respectively. The Baveno VI criteria assessed by 2D-SWE spared 25.4% of EGD screenings and missed 2.4% of the HRV patients. Combining SPD ≤11.1 cm with the Baveno VI criteria could spare more EGD screenings than just applying the Baveno VI criteria (45.1% vs 25.4%, P < 0.001), and missed 4.9% of the HRV patients. The Baveno VI criteria assessed by 2D-SWE could be safely applied in cACLD patients to rule out HRV patients. The combined model Baveno VI/SPD could safely and significantly increase the rate of spared EGD.


Assuntos
Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas , Baço , Humanos , Técnicas de Imagem por Elasticidade/métodos , Baço/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Idoso , Tamanho do Órgão , Estudos Retrospectivos , Adulto
2.
J Ultrasound Med ; 43(4): 741-749, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38158852

RESUMO

OBJECTIVES: To investigate the influence of microbubble perfusion mode on catheter-directed thrombolysis (CDT), we evaluated the effect of two different types of microbubble perfusion modes (continuous injection versus bolus injection) on the thrombolytic efficacy of CDT in vitro and further assessed the effect of continuous microbubble injection on CDT in vivo. METHODS: In an in vitro experimental setup, 50 fresh bovine whole blood clots were randomized into five groups: ultrasound and continuous microbubble injection-enhanced CDT (US + cMB + CDT), ultrasound and bolus microbubble injection-enhanced CDT (US + bMB + CDT), US + CDT, US + cMB, and CDT. In a porcine femoral vein thrombosis model, 16 completely obstructive thrombi were randomly assigned to the CDT group and the US + cMB + CDT group, respectively. Thrombolysis rate, vascular recanalization rate, hematoxylin-eosin, and immunofluorescence staining were used to evaluate the thrombolytic effect in vitro and in vivo. RESULTS: In vitro, US + cMB + CDT group resulted in a significantly higher thrombolysis rate compared with the other four groups (P < .05). Meanwhile, this group also demonstrated a looser clot structure and more disrupted fibrin structures. In vivo, US + cMB + CDT contributed to a significantly higher vascular recanalization rate compared with CDT (87.50% versus 25.00%, P < .05). CONCLUSIONS: US + cMB + CDT was more effective than US + bMB + CDT in thrombolysis, and ultrasound combined with continuous microbubble injection could enhance the thrombolytic efficacy of CDT.


Assuntos
Terapia Trombolítica , Trombose , Animais , Bovinos , Suínos , Terapia Trombolítica/métodos , Microbolhas , Fibrinolíticos , Ultrassonografia , Catéteres , Trombose/terapia , Resultado do Tratamento
3.
Ultrasound Med Biol ; 47(11): 3221-3230, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34362582

RESUMO

The aim of the study was to explore the optimal mechanical indexes (MIs) for low-intensity ultrasound (LIUS) combined with microbubbles to enhance tumor blood perfusion and improve drug concentration in pancreatic cancer-bearing nude mice. Fifty-four nude mice bearing bilateral pancreatic tumors on the hind legs were randomly divided into three groups (the MI was set at 0.3, 0.7 and 1.1 in groups A, B and C, respectively). Five nude mice in each group were intravenously injected with the fluorescent dye DiR iodide (DiIC18(7),1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbocyanine iodide); for each mouse, one tumor was treated with LIUS combined with microbubbles, and the contralateral tumor was exposed to sham ultrasound. In vivo fluorescence imaging was performed to detect the enrichment of intratumoral DiR iodide. Twelve mice in each group were intravenously injected with doxorubicin (DOX) and underwent ultrasound therapy as described above. Tumor blood perfusion changes were quantitatively evaluated with pre- and post-treatment contrast-enhanced ultrasound (CEUS, MI = 0.08). One hour after the post-treatment CEUS, nude mice were sacrificed to determine the DOX concentration in tumor tissue; one mouse in each group was sacrificed after ultrasound treatment for tumor hematoxylin-eosin staining examination. CEUS quantitative analysis and in vivo fluorescence images confirmed that LIUS at MI = 0.3 combined with microbubbles was able to enhance tumor blood flow and increase regional fluorescence dye DiR iodide concentration. The DOX concentration on the therapeutic side was significantly higher than that on the control side after ultrasound-stimulated (MI = 0.3) microbubble cavitation (USMC) treatment (1.45 ± 0.53 µg/g vs. 1.07 ± 0.46 µg/g, t = -5.163, p = 0.001). However, in groups B and C, there were no significant differences in DOX concentration between the therapeutic and control sides (Z = -0.297, -0.357, p = 0.766, 0.721). No hemorrhage or other tissue damage was observed in hematoxylin-eosin-stained tumor specimens of both sides in all groups. LIUS at MI = 0.3 combined with microbubbles was able to enhance tumor blood perfusion and improve local drug concentration in nude mice bearing pancreatic cancer.


Assuntos
Microbolhas , Neoplasias Pancreáticas , Animais , Doxorrubicina , Camundongos , Camundongos Nus , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Ultrassonografia
4.
Liver Transpl ; 22(2): 188-91, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26334555

RESUMO

Extracorporeal membrane oxygenation (ECMO) has been used to support brain-dead donors for liver procurement. This study investigated the potential role of ultrasonographic monitoring of hepatic perfusion as an aid to improve the viability of liver transplants obtained from brain-dead donors who are supported on ECMO. A total of 40 brain-dead patients maintained on ECMO served as the study population. Hepatic blood flow was monitored using ultrasonography, and perioperative optimal perfusion was maintained by calibrating ECMO. Liver function tests were performed to assess the viability of the graft. The hepatic arterial blood flow was well maintained with no significant changes observed before and after ECMO (206 ± 32 versus 241 ± 45 mL/minute; P = 0.06). Similarly, the portal venous blood flow was also maintained throughout (451 ± 65 versus 482 ± 77 mL/minute; P = 0.09). No significant change in levels of total bilirubin, alanine transaminase, and lactic acid were reported during ECMO (P = 0.17, P = 0.08, and P = 0.09, respectively). Before the liver is procured, ultrasonographic monitoring of hepatic blood flow could be a valuable aid to improve the viability of a liver transplant by allowing for real-time calibration of ECMO perfusion in brain-dead liver donors. In our study, ultrasonographic monitoring helped prevent warm ischemic injury to the liver graft by avoiding both overperfusion and underperfusion of the liver.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Fígado , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Adolescente , Adulto , Alanina Transaminase/sangue , Bilirrubina/análise , Bilirrubina/sangue , Velocidade do Fluxo Sanguíneo , Morte Encefálica , Calibragem , Estudos de Coortes , Feminino , Humanos , Ácido Láctico/sangue , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Perfusão , Veia Porta/patologia , Fatores de Tempo , Doadores de Tecidos , Ultrassonografia , Adulto Jovem
5.
Chin Med Sci J ; 30(2): 70-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26148995

RESUMO

OBJECTIVE: To investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy) in assessing tubal patency with chromolaporoscopy. METHODS: A total of 157 infertile women underwent 3D-HyCoSy to evaluate tubal patency. Among these patients, 39 patients were also examined by chromolaporoscopy. The concordance of the two clinical assessment methods was analyzed by the Kappa coefficient test. RESULTS: Among the 306 oviducts examined by 3D-HyCoSy, 99 (32.4%) were patent, 126 (41.2%) partially obstructed, and 81 (26.5%) completely obstructed. Diagnostic results with 3D-HyCoSy were not statistically different from those obtained in the 39 women (78 oviducts) who also underwent chromolaporoscopy, and the two methods showed a high concordance (k=0.747, P=0.000). The 3D-HyCoSy procedure had a sensitivity of 84.8% (28/33), a specificity of 96.2% (25/26), and positive and negative predictive values of 93.3% (28/30) and 86.2% (25/29) respectively. CONCLUSION: Transvaginal 3D-HyCoSy can accurately reveal the spatial path and morphology of the oviduct and is a safe and effective method to evaluate tubal patency.


Assuntos
Testes de Obstrução das Tubas Uterinas/métodos , Tubas Uterinas/diagnóstico por imagem , Histerossalpingografia , Imageamento Tridimensional , Infertilidade Feminina/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Laparoscopia , Ultrassonografia
6.
Liver Transpl ; 18(8): 966-71, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22511324

RESUMO

The aim of this study was to investigate the use of contrast-enhanced ultrasound (CEUS) for the detection of splenic artery steal syndrome (SASS) after orthotopic liver transplantation (OLT). Two hundred forty-seven patients underwent OLT. Blood tests and color Doppler flow imaging (CDFI) were performed at various time points after the operation. CEUS and celiac angiography were used for patients suspected of having SASS. If the diagnosis of SASS was confirmed, splenic artery embolization was performed to enhance hepatic artery flow. CEUS and angiography were performed for the assessment of postinterventional clinical outcomes. Three of the 247 patients died postoperatively, and 8 patients were suspected of having SASS because of elevated liver enzyme levels and slim or undetectable hepatic artery blood signals by CDFI at various points after the operation. In these 8 patients, CEUS showed a delayed and weak contrast-enhanced blood signal in the hepatic artery associated with a rapid and intense enhancement of the portal vein blood. No narrowing of the hyperintense signal was observed in the hepatic artery by CEUS. The 8 diagnoses of SASS were proven by celiac angiography, which showed delayed perfusion of the hepatic artery and rapid filling of the splenic artery. Immediately after the interventional procedure, CEUS demonstrated a significantly enlarged hyperintense blood signal in the hepatic artery. In conclusion, approximately 3.27% of SASS cases occur after OLT. SASS can be identified as a sluggish and weak hyperintense blood signal in the hepatic artery without the narrowing and interruption of the hypointense signal in CEUS imaging. CEUS is an effective imaging modality for the detection of SASS after OLT.


Assuntos
Meios de Contraste/farmacologia , Transplante de Fígado/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Artéria Esplênica/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Estudos Retrospectivos , Esplenopatias/diagnóstico por imagem , Esplenopatias/etiologia , Síndrome , Fatores de Tempo , Ultrassonografia Doppler/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...