Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616798

RESUMO

This study evaluates accelerometer performance of three new state of the art smartphones and focuses on accuracy. The motivating research question was whether accelerator accuracy obtained with these off-the-shelf modern smartphone accelerometers was or was not statistically different from that of a gold-standard reference system. We predicted that the accuracy of the three modern smartphone accelerometers in human movement data acquisition do not differ from that of the Vicon MX motion capture system. To test this prediction, we investigated the comparative performance of three different commercially available current generation smartphone accelerometers among themselves and to a gold-standard Vicon MX motion capture system. A single subject design was implemented for this study. Pearson's correlation coefficients® were calculated to verify the validity of the smartphones' accelerometer data against that of the Vicon MX motion capture system. The Intraclass Correlation Coefficient (ICC) was used to assess the smartphones' accelerometer performance reliability compared to that of the Vicon MX motion capture system. Results demonstrated that (a) the tested smartphone accelerometers are valid and reliable devices for estimating accelerations and (b) there were not significant differences among the three current generation smartphones and the Vicon MX motion capture system's mean acceleration data. This evidence indicates how well recent generation smartphone accelerometer sensors are capable of measuring human body motion. This study, which bridges a significant information gap between the accuracy of accelerometers measured close to production and their accuracy in actual smartphone research, should be interpreted within the confines of its scope, limitations and strengths. Further research is warranted to validate our arguments, suggestions, and results, since this is the first study on this topic.


Assuntos
Movimento , Smartphone , Humanos , Reprodutibilidade dos Testes , Acelerometria/métodos
2.
Sensors (Basel) ; 21(22)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34833607

RESUMO

It is recognized that gait analysis is a powerful tool used to capture human locomotion and quantify the related parameters. PODOSmart® insoles have been designed to provide accurate measurements for gait analysis. PODOSmart® insoles are lightweight, slim and cost-effective. A recent publication presented the characteristics and data concerning the validity of PODOSmart® insoles in gait analysis. In literature, there is still no evidence about the repeatability of PODOSmart® gait analysis system. Such evidence is essential in order to use this device in both research and clinical settings. The aim of the present study was to assess the repeatability of PODOSmart® system. In this context, it was hypothesized that the parameters of gait analysis captured by PODOSmart® would be repeatable. In a sample consisting of 22 healthy male adults, participants performed two walking trials on a six-meter walkway. The ICC values for 28 gait variables provided by PODOSmart® indicated good to excellent test-retest reliability, ranging from 0.802 to 0.997. The present findings confirm that PODOSmart® gait analysis insoles present excellent repeatability in gait analysis parameters. These results offer additional evidence regarding the reliability of this gait analysis tool.


Assuntos
Análise da Marcha , Sapatos , Adulto , Marcha , Humanos , Masculino , Reprodutibilidade dos Testes , Caminhada
3.
Sensors (Basel) ; 21(17)2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34502861

RESUMO

The new smart insole PODOSmart®, is introduced as a new tool for gait analysis against high cost laboratory based equipment. PODOSmart® system measures walking profile and gait variables in real life conditions. PODOSmart® insoles consists of wireless sensors, can be fitted into any shoe and offer the ability to measure spatial, temporal, and kinematic gait parameters. The intelligent insoles feature several sensors that detect and capture foot movements and a microprocessor that calculates gait related biomechanical data. Gait analysis results are presented in PODOSmart® platform. This study aims to present the characteristics of this tool and to validate it comparing with a stereophotogrammetry-based system. Validation was performed by gait analysis for eleven healthy individuals on a six-meters walkway using both PODOSmart® and Vicon system. Intraclass correlation coefficients (ICC) were calculated for gait parameters. ICC for the validation ranged from 0.313 to 0.990 in gait parameters. The highest ICC was observed in cadence, circumduction, walking speed, stride length and stride duration. PODOSmart® is a valid tool for gait analysis compared to the gold standard Vicon. As PODOSmart®, is a portable gait analysis tool with an affordable cost it can be a useful novel tool for gait analysis in healthy and pathological population.


Assuntos
Marcha , Sapatos , Fenômenos Biomecânicos , Análise da Marcha , Humanos , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...