Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Exp Eye Res ; 212: 108768, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34534541

RESUMO

The mouse lens is frequently used both in vivo and ex vivo in ophthalmic research to model conditions affecting the human lens, such as presbyopia. The mouse lens has a delicate structure which is prone to damage and biomechanical changes both before and after extraction from the whole globe. When not properly controlled for, these changes can confound the biomechanical analysis of mouse lenses. In this study, atomic force microscopy microindentation was used to assess changes in the Young's Modulus of Elasticity of the mouse lens as a function of mouse age and postmortem time. Old mouse lenses measured immediately postmortem were significantly stiffer than young mouse lenses (p = 0.028). However, after 18 h of incubation, there was no measurable difference in lens stiffness between old and young mouse lenses (p = 0.997). This demonstrates the need for careful experimental control in experiments using the mouse lens, especially regarding postmortem time.


Assuntos
Envelhecimento , Cápsula do Cristalino/fisiologia , Cristalino/fisiologia , Microscopia de Força Atômica/métodos , Animais , Elasticidade , Feminino , Cápsula do Cristalino/citologia , Cristalino/citologia , Camundongos , Modelos Animais
2.
Ann Biomed Eng ; 43(4): 906-16, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25266935

RESUMO

The objective of this study is to further investigate the ultrastructural details of the surface of Bowman's membrane of the human cornea, using atomic force microscopy (AFM) images. One representative image acquired of Bowman's membrane of a human cornea was investigated. The three-dimensional (3-D) surface of the sample was imaged using AFM in contact mode, while the sample was completely submerged in optisol solution. Height and deflection images were acquired at multiple scan lengths using the MFP-3D AFM system software (Asylum Research, Santa Barbara, CA), based in IGOR Pro (WaveMetrics, Lake Oswego, OR). A novel approach, based on computational algorithms for fractal analysis of surfaces applied for AFM data, was utilized to analyze the surface structure. The surfaces revealed a fractal structure at the nanometer scale. The fractal dimension, D, provided quantitative values that characterize the scale properties of surface geometry. Detailed characterization of the surface topography was obtained using statistical parameters, in accordance with ISO 25178-2: 2012. Results obtained by fractal analysis confirm the relationship between the value of the fractal dimension and the statistical surface roughness parameters. The surface structure of Bowman's membrane of the human cornea is complex. The analyzed AFM images confirm a fractal nature of the surface, which is not taken into account by classical surface statistical parameters. Surface fractal dimension could be useful in ophthalmology to quantify corneal architectural changes associated with different disease states to further our understanding of disease evolution.


Assuntos
Lâmina Limitante Anterior/ultraestrutura , Fractais , Imageamento Tridimensional , Microscopia de Força Atômica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...