Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Nephrol ; 29(4): 1336-1343, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29472415

RESUMO

Central venous catheters (CVCs) contribute disproportionately to bloodstream infection (BSI) and, by extension, to infection-related hospitalization, mortality, and health care costs in patients undergoing dialysis. Recent product advancements may reduce BSIs, but a sufficiently powered comparative-effectiveness study is needed to facilitate evidence-based patient care decisions. In a 13-month, prospective, cluster-randomized, open-label trial, we compared BSI rates in facilities using ClearGuard HD antimicrobial barrier caps (ClearGuard group) with those in facilities using Tego hemodialysis connectors plus Curos disinfecting caps (Tego+Curos group). Forty DaVita dialysis facilities in the United States were pair-matched by BSI rate, number of patients using CVCs, and geographic location, and then cluster randomized 1:1. We enrolled all adult patients undergoing dialysis with CVCs at these facilities, except those allergic to heparin or chlorhexidine. Overall, 1671 patients participated in the study, accruing >183,000 CVC-days. The study outcome was positive blood culture (PBC) rate as an indicator of BSI rate. We calculated results at the cluster level and adjusted for the facility cluster effect. During a 3-month run-in period immediately before study interventions, the groups had similar BSI rates (P=0.8). During the 13-month intervention period that immediately followed, the ClearGuard group had a BSI rate significantly lower than that of the Tego+Curos group (0.28 versus 0.75 PBCs per 1000 CVC-days, respectively; P=0.001). No device-related adverse events were reported. In conclusion, compared with Tego connectors plus Curos caps, ClearGuard HD antimicrobial barrier caps significantly lowered the rate of catheter-related BSIs in patients undergoing hemodialysis using CVCs, representing an important advancement in hemodialysis patient care.


Assuntos
Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres Venosos Centrais/efeitos adversos , Desinfecção/instrumentação , Diálise Renal/instrumentação , 2-Propanol/administração & dosagem , Idoso , Antibioticoprofilaxia , Bacteriemia/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Clorexidina/administração & dosagem , Desinfetantes/administração & dosagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Am J Kidney Dis ; 69(2): 220-227, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27839894

RESUMO

BACKGROUND: The rate of bloodstream infections (BSIs) is disproportionately high in hemodialysis (HD) patients with central venous catheters (CVCs) versus those with permanent accesses, contributing to poorer outcomes, such as increased rates of death and hospitalizations. STUDY DESIGN: 12-month, prospective, cluster-randomized, multicenter, open-label trial. SETTING & PARTICIPANTS: 40 Fresenius Medical Care North America dialysis facilities were matched and paired by positive blood culture rate and number of patients with CVCs and then cluster-randomized with 20 in each study group. 2,470 patients participated in the study (1,245, intervention group; 1,225, control group), accruing approximately 350,000 CVC-days. INTERVENTION: Use of ClearGuard HD Antimicrobial Barrier Caps versus use of standard CVC caps; assigned at the facility level. OUTCOME: Primary end point was positive blood culture rate as an indicator of BSI rate. MEASUREMENTS: Positive blood cultures, hospital admissions for BSI, hospitalization-days for BSI, intravenous antibiotic starts, and CVC-days. RESULTS: Baseline positive blood culture rates were similar (P=0.8) between groups. Use of ClearGuard HD caps for 12 months was associated with a 56% lower BSI rate versus use of standard CVC caps (0.26 vs 0.59/1,000 CVC-days, respectively; P=0.01). When considering sustained use (defined as last 6 months of the study), the intervention versus the control was associated with a 69% lower BSI rate (0.22 vs 0.72/1,000 CVC-days, respectively; P=0.01), 43% fewer hospital admissions for BSI (0.28 vs 0.48/1,000 CVC-days, respectively; P=0.04), and 51% fewer hospitalization days for BSI (2.42 vs 4.94/1,000 CVC-days, respectively; P=0.04). No device-related adverse events were reported. LIMITATIONS: Study was open label; patients occasionally received HD at nonresearch facilities; patients did not receive the intervention when hospitalized. CONCLUSIONS: The findings show that use of ClearGuard HD Antimicrobial Barrier Caps, when compared with standard CVC caps, significantly lowers rates of catheter-related BSIs and hospital admissions for BSI in HD patients using CVCs.


Assuntos
Anti-Infecciosos/uso terapêutico , Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres de Demora/efeitos adversos , Diálise Renal/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...