Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 109(4): 1086-1095, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33197530

RESUMO

PURPOSE: Our purpose was to assess the use of machine learning methods and Mobius 3D (M3D) dose calculation software to reduce the number of physical ion chamber (IC) dose measurements required for patient-specific quality assurance during corona virus disease 2019. METHODS AND MATERIALS: In this study, 1464 inversely planned treatments using Pinnacle or Raystation treatment planning software (TPS) were delivered using Elekta Versa HD and Varian Truebeam and Truebeam STx linear accelerators between June 2018 and November 2019. For each plan, an independent dose calculation was performed using M3D, and an absolute dose measurement was taken using a Pinpoint IC inside the Mobius phantom. The point dose differences between the TPS and M3D calculation and between TPS and IC measurements were calculated. Agreement between the TPS and IC was used to define the ground truth plan failure. To reduce the on-site personnel during the pandemic, 2 methods of receiver operating characteristic analysis (n = 1464) and machine learning (n = 603) were used to identify patient plans that would require physical dose measurements. RESULTS: In the receiver operating characteristic analysis, a predelivery M3D difference threshold of 3% identified plans that failed an IC measurement at a 4% threshold with 100% sensitivity and 76.3% specificity. This indicates that fewer than 25% of plans required a physical dose measurement. A threshold of 1% on a machine learning model was able to identify plans that failed an IC measurement at a 3% threshold with 100% sensitivity and 54.3% specificity, leading to fewer than 50% of plans that required a physical dose measurement. CONCLUSIONS: It is possible to identify plans that are more likely to fail IC patient-specific quality assurance measurements before delivery. This possibly allows for a reduction of physical measurements taken, freeing up significant clinical resources and reducing the required amount of on-site personnel while maintaining patient safety.


Assuntos
Aprendizado de Máquina , Curva ROC , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde
2.
Phys Med Biol ; 59(23): 7211-27, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25369288

RESUMO

Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.


Assuntos
Algoritmos , Fótons , Espectrometria por Raios X/normas , Calibragem , Estudos de Viabilidade , Espectrometria por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...