Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 27(2): 146-53, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22749436

RESUMO

BACKGROUND: Ultrasonographic (US) assessment of abdominal aortic aneurysms is typically performed by measuring maximal aneurysm diameter from two-dimensional images. These measurements are prone to inaccuracies owing to image planes and interobserver variability. The purpose of this study was to compare the variability in diameter, cross-sectional area (CSA), and volume measurements of abdominal aortic aneurysms obtained using a three-dimensional (3D) US imaging system with those obtained using computed tomographic (CT) angiography, and to determine the reliability of these measures. METHODS: Seven patients in whom endovascular aneurysm repairs were performed underwent CT angiography in addition to a 3D US scan. Measurements computed using 3D surface reconstructions of CT and 3D US scans included maximum diameter, CSA, and aneurysm volume. The seven matched CT and 3D US scans were compared at baseline and 6 to 8 weeks later. RESULTS: The average aneurysm measured 57.2 mm on CT and 56.2 mm on US (P = 0.14). Correlation coefficients for diameter, CSA, and volume were 0.88, 0.90, and 0.93, respectively (all P values < 0.001). A Bland-Altman analysis demonstrated a strong agreement between 92% of the diameter, 96.4% of the CSA, and 100% of the volume measurements. The interrater reliability was remarkably high comparing the modalities (CT vs. US), and ranged from 0.934 to 0.997 for single measurements and 0.965 to 0.998 for all measurements together; moreover, there was a strong reliability when the tests were reviewed 6 to 8 weeks later, with a reliability of 0.962 to 0.998 for single measurements and 0.992 to 0.999 for all tests (all P values < 0.001). CONCLUSIONS: The 3D US is an accurate and noninvasive method of determining aneurysm size and geometry that is reproducible. Volumetric measurements may represent a significant advancement in long-term follow-up after endovascular aneurysm repair.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...