Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
ESC Heart Fail ; 8(6): 5583-5588, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34704672

RESUMO

AIMS: Our study aimed to investigate the cardiac involvement with sensitive tissue characterization in non-hospitalized children with coronavirus disease 2019 (COVID-19) infection using cardiovascular magnetic resonance (CMR) imaging. METHODS AND RESULTS: We prospectively enrolled children who recovered from mildly symptomatic COVID-19 infection between November 2020 and January 2021. Patients underwent CMR at 1.5 T (Achieva, Philips Healthcare, Best, the Netherlands) including cine images, native T1 and T2 mapping. Healthy children and paediatric patients with biopsy-proven myocarditis served as control groups. We performed CMR in 18 children with a median (25th-75th percentile) age of 12 (10-15) years, 38 (24-47) days after positive PCR test, and compared them with 7 healthy controls [15 (10-19) years] and 9 patients with myocarditis [10 (4-16) years]. The COVID-19 patients reported no cardiac symptoms. None of the COVID-19 patients showed CMR findings consistent with a myocarditis. Three patients (17%) from the COVID-19 cohort presented with minimal pericardial effusion. CMR parameters of COVID-19 patients, including volumetric and strain values as well as T1 and T2 times, were not significantly different from healthy controls, but from myocarditis patients. These had significantly reduced left ventricular (LV) ejection fraction (P = 0.035), LV global longitudinal strain, and left atrial strain values as well as elevated native T1 values compared with COVID-19 patients (P < 0.001, respectively). CONCLUSIONS: There was no evidence of myocardial inflammation, fibrosis, or functional cardiac impairment in the studied cohort of children recently. CMR findings were comparable with those of healthy controls. Pericardial effusion suggests a mild pericarditis in a small subgroup. This is pointing to a minor clinical relevance of myocardial involvement in children after mildly symptomatic COVID-19 infections.


Assuntos
COVID-19 , Miocardite , Adolescente , Criança , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocardite/diagnóstico , Miocardite/epidemiologia , SARS-CoV-2
2.
ESC Heart Fail ; 8(2): 890-897, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33539681

RESUMO

AIMS: Although heart failure (HF) is a leading cause for hospitalization and mortality, normalized and comparable non-invasive assessment of haemodynamics and myocardial action remains limited. Moreover, myocardial deformation has not been compared between the guideline-defined HF entities. The distribution of affected and impaired segments within the contracting left ventricular (LV) myocardium have also not been compared. Therefore, we assessed myocardial function impairment by strain in patients with HF and control subjects by magnetic resonance imaging after clinically phenotyping these patients. METHODS AND RESULTS: This prospective study conducted at two centres in Germany between 2017 and 2018 enrolled stable outpatient subjects with HF [n = 56, including HF with reduced ejection fraction (HFrEF), HF with mid-range ejection fraction (HFmrEF), and HF with preserved ejection fraction (HFpEF)] and a control cohort (n = 12). Parameters assessed included measures for external myocardial function, for example, cardiac index and myocardial deformation measurements by cardiovascular magnetic resonance imaging, left ventricular global longitudinal strain (GLS), the global circumferential strain (GCS) and the regional distribution of segment deformation within the LV myocardium, as well as basic phenotypical characteristics. Comparison of the cardiac indices at rest showed no differences neither between the HF groups nor between the control group and HF patients (one-way ANOVA P = 0.70). The analysis of the strain data revealed differences between all groups in both LV GLS (One-way ANOVA: P < 0.01. Controls vs. HFpEF: -20.48 ± 1.62 vs. -19.27 ± 1.25. HFpEF vs. HFmrEF: -19.27 ± 1.25 vs. -15.72 ± 2.76. HFmrEF vs. HFrEF: -15.72 ± 2.76 vs. -11.51 ± 3.97.) and LV GCS (One-way ANOVA: P < 0.01. Controls vs. HFpEF: -19.74 ± 2.18 vs. -17.47 ± 2.10. HFpEF vs. HFmrEF: -17.47 ± 2.10 vs. -12.78 ± 3.47. HFrEF: -11.41 ± 3.27). Comparing the segment deformation distribution patterns highlighted the discriminating effect between the groups was much more prominent between the groups (one-way ANOVA P < 0.01) when compared by a score combining regional effects and a global view on the LV. Further analyses of the patterns among the segments affected showed that while the LVEF is preserved in HFpEF, the segments impaired in their contractility are located in the ventricular septum. The worse the LVEF is, the more segments are affected, but the septum remains an outstanding location with the most severe contractility impairment throughout the HF entities. CONCLUSIONS: While cardiac index at rest did not differ significantly between controls and stable HF patients suffering from HFrEF, HFmrEF, or HFpEF, the groups did differ significantly in LV GLS and LV GCS values. Regional strain analysis revealed that the LV septum is the location affected most, with reduced values already visible in HFpEF and further reductions in HFmrEF and HFrEF.


Assuntos
Insuficiência Cardíaca , Alemanha , Insuficiência Cardíaca/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Miocárdio , Estudos Prospectivos , Volume Sistólico
3.
JACC Cardiovasc Imaging ; 14(6): 1177-1188, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33454266

RESUMO

OBJECTIVES: The purpose of this study was to compare the ability of fast-strain encoded magnetic resonance (fast-SENC) cardiac magnetic resonance (CMR) to classify and risk stratify all-comer patients with different stages of chronic heart failure (Stages of heart failure A to D) based on American College of Cardiology/American Heart Association guidelines with standard clinical and CMR imaging data. BACKGROUND: Heart failure is a major cause of morbidity and mortality, resulting in millions of deaths and hospitalizations annually. METHODS: The study population consisted of 1,169 consecutive patients between September 2017 and February 2019 who underwent CMR for clinical reasons, and 61 healthy volunteers. In addition, clinical follow-up was performed in Stages A and B patients after 1.9 ± 0.4 years. Wall motion score and late gadolinium enhancement score indexes, left ventricular (LV) ejection fraction, and global circumferential and longitudinal strain based on fast-SENC acquisitions, were calculated in all subjects. The percentage of myocardial segments with strain ≤-17% (% normal myocardium) was determined in all subjects. RESULTS: LV ejection fraction, global circumferential and longitudinal strain, and % normal myocardium significantly decreased with increasing heart failure stages (p < 0.001 for all by analysis of variance). By multivariable analysis, % normal myocardium remained an independent predictor of heart failure stages, exhibiting closer association than LV ejection fraction (rpartial = 0.76 vs. rpartial = 0.30; p < 0.001). Importantly, 149 of 399 (37%) with Stage A were reclassified to Stage B, that is, as having subclinical LV dysfunction based on % normal myocardium <80%. Such patients exhibited significantly higher rates of all-cause mortality and hospital stay due to heart failure during follow-up, compared with patients with % normal myocardium ≥80% (chi-square = 6.9; p = 0.03). CONCLUSIONS: The % normal myocardium, determined by fast-SENC, enables improved identification of asymptomatic patients with subclinical LV dysfunction compared with LV ejection fraction and risk stratification of patients with so far asymptomatic heart failure. The identification of such presumably healthy patients at high risk for heart failure-related outcomes may bear important medical implications.


Assuntos
Meios de Contraste , Insuficiência Cardíaca , Gadolínio , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Medição de Risco , Estados Unidos
4.
Magn Reson Med ; 85(1): 357-368, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32851707

RESUMO

PURPOSE: Myocardial feature-tracking (FT) deformation imaging is superior for risk stratification compared with volumetric approaches. Because there is no clear recommendation regarding FT postprocessing, we compared different FT-strain analyses with reference standard techniques, including tagging and strain-encoded (SENC) MRI. METHODS: Feature-tracking software from four different vendors (TomTec, Medis, Circle [CVI], and Neosoft), tagging (Segment), and fastSENC (MyoStrain) were used to determine left ventricular global circumferential strains (GCS) and longitudinal strains (GLS) in 12 healthy volunteers and 12 patients with heart failure. Variability and agreements were assessed using intraclass correlation coefficients for absolute agreement (ICCa) and consistency (ICCc) as well as Pearson correlation coefficients. RESULTS: For FT-GCS, consistency was excellent comparing different FT vendors (ICCc = 0.84-0.97, r = 0.86-0.95) and in comparison to fast SENC (ICCc = 0.78-0.89, r = 0.73-0.81). FT-GCS consistency was excellent compared with tagging (ICCc = 0.79-0.85, r = 0.74-0.77) except for TomTec (ICCc = 0.68, r = 0.72). Absolute FT-GCS agreements among FT vendors were highest for CVI and Medis (ICCa = 0.96) and lowest for TomTec and Neosoft (ICCa = 0.32). Similarly, absolute FT-GCS agreements were excellent for CVI and Medis compared with both tagging and fast SENC (ICCa = 0.84-0.88), good to excellent for Neosoft (ICCa = 0.77 and 0.64), and lowest for TomTec (ICCa = 0.41 and 0.47). For FT-GLS, consistency was excellent (ICCc ≥ 0.86, r ≥ 0.76). Absolute agreements among FT vendors were excellent (ICCa = 0.91-0.93) or good to excellent for TomTec (ICCa = 0.69-0.85). Absolute agreements (ICCa) were good (CVI 0.70, Medis 0.60) and fair (TomTec 0.41, Neosoft 0.59) compared with tagging, but excellent compared with fast SENC (ICCa = 0.77-0.90). CONCLUSION: Although absolute agreements differ depending on deformation assessment approaches, consistency and correlation are consistently high regardless of the method chosen, thus indicating reliable strain assessment. Further standardisation and introduction of uniform references is warranted for routine clinical implementation.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Ventrículos do Coração/diagnóstico por imagem , Humanos , Miocárdio , Reprodutibilidade dos Testes , Função Ventricular Esquerda
5.
Front Cardiovasc Med ; 8: 737257, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35004872

RESUMO

Background: Despite the ongoing global pandemic, the impact of COVID-19 on cardiac structure and function is still not completely understood. Myocarditis is a rare but potentially serious complication of other viral infections with variable recovery, and is, in some cases, associated with long-term cardiac remodeling and functional impairment. Aim: To assess myocardial injury in patients who recently recovered from an acute SARS-CoV-2 infection with advanced cardiac magnetic resonance imaging (CMR) and endomyocardial biopsy (EMB). Methods: In total, 32 patients with persistent cardiac symptoms after a COVID-19 infection, 22 patients with acute classic myocarditis not related to COVID-19, and 16 healthy volunteers were included in this study and underwent a comprehensive baseline CMR scan. Of these, 10 patients post COVID-19 and 13 with non-COVID-19 myocarditis underwent a follow-up scan. In 10 of the post-COVID-19 and 15 of the non-COVID-19 patients with myocarditis endomyocardial biopsy (EMB) with histological, immunohistological, and molecular analysis was performed. Results: In total, 10 (31%) patients with COVID-19 showed evidence of myocardial injury, eight (25%) presented with myocardial oedema, eight (25%) exhibited global or regional systolic left ventricular (LV) dysfunction, and nine (28%) exhibited impaired right ventricular (RV) function. However, only three (9%) of COVID-19 patients fulfilled updated CMR-Lake Louise criteria (LLC) for acute myocarditis. Regarding EMB, none of the COVID-19 patients but 87% of the non-COVID-19 patients with myocarditis presented histological findings in keeping with acute or chronic inflammation. COVID-19 patients with severe disease on the WHO scale presented with reduced biventricular longitudinal function, increased RV mass, and longer native T1 times compared with those with only mild or moderate disease. Conclusions: In our cohort, CMR and EMB findings revealed that SARS-CoV-2 infection was associated with relatively mild but variable cardiac involvement. More symptomatic COVID-19 patients and those with higher clinical care demands were more likely to exhibit chronic inflammation and impaired cardiac function compared to patients with milder forms of the disease.

6.
Front Cardiovasc Med ; 7: 111, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32714945

RESUMO

Background: Fast strain-encoded cardiac magnetic resonance imaging (cMRI, fast-SENC) is a novel technology potentially improving characterization of heart failure (HF) patients by quantifying cardiac strain. We sought to describe the impact of isometric handgrip exercise (HG) on cardiac strain assessed by fast-SENC in HF patients and controls. Methods: Patients with stable HF and controls were examined using cMRI at rest and during HG. Left ventricular (LV) global longitudinal strain (GLS) and global circumferential (GCS) were derived from image analysis software using fast-SENC. Strain change < -0.5 and > +0.5 was classified as increase and decrease, respectively. Results: The study population comprised 72 subjects, including HF with reduced, mid-range and preserved ejection fraction and controls (HFrEF n = 18 HFmrEF n = 18, HFpEF n = 17, controls: n = 19). In controls, LV GLS remained stable in 36.8%, increased in 36.8% and decreased in 26.3% of subjects during HG. In HF subgroups, similar patterns of LV GLS response were observed (HFpEF: stable 41.2%, increase 35.3%, decrease: 23.5%; HFmrEF: stable 50.0%, increase 16.7%, decrease: 33.3%; HFrEF: stable 33.3%, increase 22.2%, decrease: 44.4%, p = 0.668). Mean change between LV GLS at rest and during HG ranged close to zero with broad standard deviation in all subgroups and was not significantly different between subgroups (+1.2 ± 5.4%, -0.6 ± 8.3%, -1.7 ± 10.7%, and -3.1 ± 19.4%, p = 0.746 in controls, HFpEF, HFmrEF and HFrEF, respectively). However, the absolute value of LV GLS change-irrespective of increase or decrease-was significantly different between subgroups with 4.4 ± 3.2% in controls, 5.9 ± 5.7% in HFpEF, 6.8 ± 8.3% in HFmrEF and 14.1 ± 13.3% in HFrEF (p = 0.005). The absolute value of LV GLS change significantly correlated with resting LVEF, NTproBNP and Minnesota Living with Heart Failure questionnaire scores. Conclusion: The response to isometric exercise in LV GLS is heterogeneous in all HF subgroups and in controls. The absolute value of LV GLS change during HG exercise is elevated in HF patients and associated with measures of HF severity. The diagnostic utility of fast-SENC strain assessment in conjunction with HG appears to be limited. Trial Registration: URL: https://www.drks.de; Unique Identifier: DRKS00015615.

7.
Int J Cardiovasc Imaging ; 36(5): 899-911, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32056087

RESUMO

Myocardial strain is a convenient parameter to quantify left ventricular (LV) function. Fast strain-encoding (fSENC) enables the acquisition of cardiovascular magnetic resonance images for strain-measurement within a few heartbeats during free-breathing. It is necessary to analyze inter-vendor agreement of techniques to determine strain, such as fSENC, in order to compare existing studies and plan multi-center studies. Therefore, the aim of this study was to investigate inter-vendor agreement and test-retest reproducibility of fSENC for three major MRI-vendors. fSENC-images were acquired three times in the same group of 15 healthy volunteers using 3 Tesla scanners from three different vendors: at the German Heart Institute Berlin, the Charité University Medicine Berlin-Campus Buch and the Theresien-Hospital Mannheim. Volunteers were scanned using the same imaging protocol composed of two fSENC-acquisitions, a 15-min break and another two fSENC-acquisitions. LV global longitudinal and circumferential strain (GLS, GCS) were analyzed by a trained observer (Myostrain 5.0, Myocardial Solutions) and for nine volunteers repeatedly by another observer. Inter-vendor agreement was determined using Bland-Altman analysis. Test-retest reproducibility and intra- and inter-observer reproducibility were analyzed using intraclass correlation coefficient (ICC) and coefficients of variation (CoV). Inter-vendor agreement between all three sites was good for GLS and GCS, with biases of 0.01-1.88%. Test-retest reproducibility of scans before and after the break was high, shown by ICC- and CoV values of 0.63-0.97 and 3-9% for GLS and 0.69-0.82 and 4-7% for GCS, respectively. Intra- and inter-observer reproducibility were excellent for both parameters (ICC of 0.77-0.99, CoV of 2-5%). This trial demonstrates good inter-vendor agreement and test-retest reproducibility of GLS and GCS measurements, acquired at three different scanners from three different vendors using fSENC. The results indicate that it is necessary to account for a possible bias (< 2%) when comparing strain measurements of different scanners. Technical differences between scanners, which impact inter-vendor agreement, should be further analyzed and minimized.DRKS Registration Number: 00013253.Universal Trial Number (UTN): U1111-1207-5874.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Adulto , Desenho de Equipamento , Feminino , Alemanha , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
8.
ESC Heart Fail ; 7(2): 523-532, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31800152

RESUMO

AIMS: A multitude of cardiac magnetic resonance (CMR) techniques are used for myocardial strain assessment; however, studies comparing them are limited. We sought to compare global longitudinal (GLS), circumferential (GCS), segmental longitudinal (SLS), and segmental circumferential (SCS) strain values, as well as reproducibility between CMR feature tracking (FT), tagging (TAG), and fast-strain-encoded (fast-SENC) CMR techniques. METHODS AND RESULTS: Eighteen subjects (11 healthy volunteers and seven patients with heart failure) underwent two CMR scans (1.5T, Philips) with identical parameters. Global and segmental strain values were measured using FT (Medis), TAG (Medviso), and fast-SENC (Myocardial Solutions). Friedman's test, linear regression, Pearson's correlation coefficient, and Bland-Altman analyses were used to assess differences and correlation in measured GLS and GCS between the techniques. Two-way mixed intra-class correlation coefficient (ICC), coefficient of variance (COV), and Bland-Altman analysis were used for reproducibility assessment. All techniques correlated closely for GLS (Pearson's r: 0.86-0.92) and GCS (Pearson's r: 0.85-0.94). Intra-observer and inter-observer reproducibility was excellent in all techniques for both GLS (ICC 0.92-0.99, CoV 2.6-10.1%) and GCS (ICC 0.89-0.99, CoV 4.3-10.1%). Inter-study reproducibility was similar for all techniques for GLS (ICC 0.91-0.96, CoV 9.1-10.8%) and GCS (ICC 0.95-0.97, CoV 7.6-10.4%). Combined segmental intra-observer reproducibility was good in all techniques for SLS (ICC 0.914-0.953, CoV 12.35-24.73%) and SCS (ICC 0.885-0.978, CoV 10.76-19.66%). Combined inter-study SLS reproducibility was the worst in FT (ICC 0.329, CoV 42.99%), while fast-SENC performed the best (ICC 0.844, CoV 21.92%). TAG had the best reproducibility for combined inter-study SCS (ICC 0.902, CoV 19.08%), while FT performed the worst (ICC 0.766, CoV 32.35%). Bland-Altman analysis revealed considerable inter-technique biases for GLS (FT vs. fast-SENC 3.71%; FT vs. TAG 8.35%; and TAG vs. fast-SENC 4.54%) and GCS (FT vs. fast-SENC 2.15%; FT vs. TAG 6.92%; and TAG vs. fast-SENC 2.15%). Limits of agreement for GLS ranged from ±3.1 (TAG vs. fast-SENC) to ±4.85 (FT vs. TAG) for GLS and ±2.98 (TAG vs. fast-SENC) to ±5.85 (FT vs. TAG) for GCS. CONCLUSIONS: We found significant differences in measured GLS and GCS between FT, TAG, and fast-SENC. Global strain reproducibility was excellent for all techniques. Acquisition-based techniques had better reproducibility than FT for segmental strain.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estudos de Casos e Controles , Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia
9.
Sci Rep ; 9(1): 12223, 2019 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-31434950

RESUMO

Cardiac magnetic resonance (CMR) is becoming the imaging modality of choice in multicenter studies where highly reproducible measurements are necessary. The purpose of this study was to assess the effect of comprehensive initial training on reproducibility of quantitative left ventricular (LV) parameters estimated using strain-encoded (SENC) imaging. Thirty participants (10 patients with heart failure (HF) and preserved LV ejection fraction (HFpEF), 10 patients with HF and reduced LV ejection fraction (HFrEF) and 10 healthy volunteers) were examined using fast-SENC imaging. Four observers with different experience in non-invasive cardiac imaging completed comprehensive initial training course and were invited to perform CMR data analysis. To assess agreement between observers, LV volumes, mass, ejection fraction (LVEF), global longitudinal strain (GLS) and global circumferential strain (GCS) were estimated using dedicated software (MyoStrain, USA). To test intraobserver agreement data analysis was repeated after 4 weeks. SENC imaging and analysis were fast and were completed in less than 5 minutes. LV end-diastolic volume index (LVEDVi), LVEF and strain were significantly lower in HFpEF patients than in healthy volunteers (p = 0.019 for LVEDVi; p = 0.023 for LVEF; p = 0.004 for GLS and p < 0.001 for GCS). All LV functional parameters were further reduced in HFrEF. Excellent interobserver agreement was found for all LV parameters independently of the level of experience. The reproducibility of LV mass was lower, especially at the intraobserver level (ICC 0.91; 95% CI 0.74-0.96). LV volumetric and functional parameters derived using fast-SENC imaging, are highly reproducible. The appropriate initial training is relevant and allows to achieve highest concordance in fast-SENC measurements.


Assuntos
Insuficiência Cardíaca , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
10.
BMC Cardiovasc Disord ; 19(1): 52, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30836942

RESUMO

BACKGROUND: Recently introduced fast strain-encoded (SENC) cardiac magnetic resonance (CMR) imaging (fast-SENC) provides real-time acquisition of myocardial performance in a single heartbeat. We aimed to test the ability and accuracy of real-time strain-encoded CMR imaging to estimate left ventricular volumes, ejection fraction and mass. METHODS: Thirty-five subjects (12 healthy volunteers and 23 patients with known or suspected coronary artery disease) were investigated. All study participants were imaged at 1.5 Tesla MRI scanner (Achieva, Philips) using an advanced CMR study protocol which included conventional cine and fast-SENC imaging. A newly developed real-time free-breathing SENC imaging technique based on the acquisition of two images with different frequency modulation was employed. RESULTS: All parameters were successfully derived from fast-SENC images with total study time of 105 s (a 15 s scan time and a 90 s post-processing time). There was no significant difference between fast-SENC and cine imaging in the estimation of LV volumes and EF, whereas fast-SENC underestimated LV end-diastolic mass by 7%. CONCLUSION: The single heartbeat fast-SENC technique can be used as a good alternative to cine imaging for the precise calculation of LV volumes and ejection fraction while the technique significantly underestimates LV end-diastolic mass.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Estudos de Casos e Controles , Doença da Artéria Coronariana/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia , Fluxo de Trabalho , Adulto Jovem
11.
Sci Rep ; 8(1): 14100, 2018 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-30237411

RESUMO

Myocardial strain is a well validated parameter for estimating left ventricular (LV) performance. The aim of our study was to evaluate the inter-study as well as intra- and interobserver reproducibility of fast-SENC derived myocardial strain. Eighteen subjects (11 healthy individuals and 7 patients with heart failure) underwent a cardiac MRI examination including fast-SENC acquisition for evaluating left ventricular global longitudinal (GLS) and circumferential strain (GCS) as well as left ventricular ejection fraction (LVEF). The examination was repeated after 63 [range 49‒87] days and analyzed by two experienced observers. Ten datasets were repeatedly assessed after 1 month by the same observer to test intraobserver variability. The reproducibility was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Patients with heart failure demonstrated reduced GLS and GCS compared to healthy controls (-15.7 ± 3.7 vs. -20.1 ± 1.4; p = 0.002 for GLS and -15.3 ± 3.7 vs. -21.4 ± 1.1; p = 0.001 for GCS). The test-retest analysis showed excellent ICC for LVEF (0.92), GLS (0.94) and GCS (0.95). GLS exhibited excellent ICC (0.99) in both intra- and interobserver variability analysis with very narrow limits of agreement (-0.6 to 0.5 for intraobserver and -1.3 to 0.96 for interobserver agreement). Similarly, GCS showed excellent ICC (0.99) in both variability analyses with narrow limits of agreement (-1.1 to 1.2 for intraobserver and -1.7 to 1.3 for interobserver agreement), whereas LVEF showed larger limits of agreement (-14.4 to 10.1). The analysis of fast-SENC derived myocardial strain using cardiac MRI provides a highly reproducible method for assessing LV functional performance.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...