Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Drug Metab ; 20(4): 254-265, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30727881

RESUMO

BACKGROUND: As part of an integrated and innovative approach to accelerate the clinical development of the dual receptor antagonist ACT-541468, 6 healthy subjects in one cohort in a first-in-humans (FIH) study received an oral dose of 50 mg non-labeled ACT-541468 together with a microtracer amount of 250 nCi of 14C-labeled ACT- 541468 to investigate its absorption, distribution, metabolism, and excretion (ADME). METHODS: Using accelerator mass spectrometry (AMS), radiochromatograms were constructed for fractionated plasma, urine, and feces samples. Subsequently, the structures of the metabolites were elucidated using high performance liquid chromatography (HPLC) coupled with high resolution mass spectrometry. RESULTS: In total 77 metabolites have been identified of which 30, 28, and 60 were present in plasma, urine, and feces, respectively. In plasma, the major metabolites were the mono-oxidized benzylic alcohol M3, the ACT-541468 aldehyde M1, formed by further oxidation of M3 in the benzylic position, and the doubly oxidized M10, formed by (1) benzylic oxidation of M3 (loss of one molecule of water and one molecule of ammonia) and (2) additional loss of water from the oxidized pyrrolidine ring of M5. Transformation of the pyrrolidine to a 6-membered ring was detected. Metabolites that accounted for more than 5% of total radioactivity in excreta were M2, which is also formed by oxidation at the benzylic position, M4, formed by demethylation of the methoxy-group, M7 and A6, both formed by oxidation of M4, and M10, the only major metabolite detected in urine. CONCLUSION: In conclusion, ACT-541468 is extensively metabolized predominantly by oxidative transformations.


Assuntos
Imidazóis/farmacocinética , Antagonistas dos Receptores de Orexina/farmacocinética , Pirrolidinas/farmacocinética , Área Sob a Curva , Radioisótopos de Carbono , Relação Dose-Resposta a Droga , Método Duplo-Cego , Meia-Vida , Humanos , Imidazóis/administração & dosagem , Imidazóis/química , Imidazóis/metabolismo , Estrutura Molecular , Antagonistas dos Receptores de Orexina/administração & dosagem , Antagonistas dos Receptores de Orexina/química , Antagonistas dos Receptores de Orexina/metabolismo , Pirrolidinas/administração & dosagem , Pirrolidinas/química , Pirrolidinas/metabolismo
9.
Bioanalysis ; 5(6): 711-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23484788

RESUMO

BACKGROUND: The scientifically and logistically best way of application of the internal standard (IS) in the analysis of dried blood spots (DBS) analysis is still a matter of debate and investigation. Most commonly the IS is added in the solvent used for extraction of the discs punched from DBS. In this case, the recovery of the non-extracted IS is complete while the recovery of the analyte extracted from DBS is different from the IS. RESULTS: An alternative way for addition of the IS was investigated. A homogeneous distribution and absorption of the test compound across the spots was demonstrated by spraying a solution of a radiolabeled test compound (mimicking an IS solution) onto DBS. CONCLUSION: This spray-on technique is convenient and easily automatable. Spraying of the solution was rapid, precise and reproducible, and therefore seems to be suitable for routine analysis of DBS by offline and online extraction.


Assuntos
Cromatografia em Camada Fina/métodos , Teste em Amostras de Sangue Seco/normas , Espectrometria de Massas em Tandem , Adsorção , Animais , Cafeína/sangue , Cafeína/normas , Radioisótopos de Carbono/química , Cromatografia em Camada Fina/instrumentação , Cromatografia em Camada Fina/normas , Ratos , Espectrometria de Massas em Tandem/normas
11.
Bioanalysis ; 4(17): 2117-26, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23013394

RESUMO

An open letter written by the Global CRO Council for Bioanalysis (GCC) describing the GCC survey results on stability data from co-administered and co-formulated drugs was sent to multiple regulatory authorities on 14 December 2011. This letter and further discussions at different GCC meetings led to subsequent recommendations on this topic of widespread interest within the bioanalytical community over the past 2 years.


Assuntos
Combinação de Medicamentos , Preparações Farmacêuticas/análise , Tecnologia Farmacêutica/normas , Biomarcadores/análise , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Regulamentação Governamental , Guias como Assunto , Humanos , Espectrometria de Massas em Tandem/métodos
14.
Anal Chem ; 80(11): 4200-7, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18465883

RESUMO

Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.


Assuntos
Anticorpos Monoclonais/sangue , Anticorpos Monoclonais/uso terapêutico , Coloração e Rotulagem/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Artrite Reumatoide/tratamento farmacológico , Callithrix/sangue , Isótopos de Carbono , Cromatografia Líquida , Ensaio de Imunoadsorção Enzimática , Isótopos de Nitrogênio , Peptídeos/sangue , Sensibilidade e Especificidade
15.
Photochem Photobiol Sci ; 7(2): 240-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18264593

RESUMO

Photosensitizing drugs increase the sensitivity of the skin and the eye toward normally harmless sunlight conditions and are known to enhance the induction of skin tumors or severe injuries to the eye. The photogenotoxicity of five common drugs (sparfloxacin, dacarbazine, chlorpromazine and 8-methoxypsoralen, promazine) was investigated in the skin as well as in the retina and cornea of Wistar rats. The compounds were administered once orally by gavage and the resulting DNA damage was analyzed in the newly developed in vivo photo comet assay. All drugs except of promazine were clearly photogenotoxic in the skin. In the cornea sparfloxacin and dacarbazine induced an increased DNA damage following irradiation. A photogenotoxic effect in the retina was observed by sparfloxacin, which is the only compound tested that absorbs wavelengths reaching the retina. The drug concentration analysis revealed that the compounds were distributed into plasma, skin and eye at concentrations, which were photogenotoxic in vitro. Additionally, histopathological analysis showed no relevant alterations or inductions of necrosis, apoptosis or inflammation in the skin or eye. In conclusion, we confirmed the photogenotoxic potential of compounds from different chemical classes in the skin. Moreover, it is the first time that photogenotoxicity has been detected in the retina and cornea in an in vivo study. Based on our results it is concluded that the photo comet assay in rat is an easy and reliable method to elucidate drug induced photogenotoxicity under conditions, which are relevant to human exposure.


Assuntos
Córnea/efeitos dos fármacos , Córnea/efeitos da radiação , Mutagênicos/toxicidade , Pele/efeitos dos fármacos , Pele/efeitos da radiação , Animais , Ensaio Cometa , Feminino , Ratos , Ratos Wistar
16.
J AOAC Int ; 89(3): 786-96, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16792077

RESUMO

This paper describes a selective and sensitive method that uses liquid chromatography/tandem mass spectrometry with positive electrospray ionization (ESI+) for the determination of deltamethrin in a variety of crops. Samples were extracted by conventional high-speed blending. Some samples required no further cleanup; others were cleaned up by gel permeation chromatography, strong cation-exchange cartridges, or partitioning with n-hexane. In the determinative step, the buffered neutral mobile phase, consisting of 10 mM ammonium acetate (pH 6.8) and methanol, and ESI+ provided strong ammonium adduct formation to [M+NH4]+ at m/z 523, and the multiple-reaction monitoring (MRM) transition at m/z 523/281 was used for the quantitation of deltamethrin. A second MRM transition at m/z 525/283 was used for confirmation. The limit of quantitation (LOQ) values were 0.01 mg/kg for edible materials and 0.05 mg/kg for nonedible materials. Mean overall recoveries at the LOQ and the 10-fold LOQ ranged from 73 to 96%, and the relative standard deviations were <10% for all samples materials analyzed.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Líquida/métodos , Nitrilas/análise , Plantas/metabolismo , Piretrinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Calibragem , Cromatografia Líquida de Alta Pressão , Hordeum/metabolismo , Inseticidas/análise , Modelos Químicos , Resíduos de Praguicidas/análise , Reprodutibilidade dos Testes , Manejo de Espécimes/métodos , Temperatura , Triticum/metabolismo
17.
Rapid Commun Mass Spectrom ; 17(17): 1950-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12913858

RESUMO

Some cases of occurrence of matrix effects (mostly ion suppression) in protein-precipitated plasma samples, and their influence on the validity of plasma concentrations and pharmacokinetic parameters, are discussed. The comparison of matrix effects using either electrospray (TurboIonspray, TISP) or atmospheric pressure chemical ionization (APCI) indicated that APCI is less prone to matrix effects. Nevertheless, TISP is usually the first choice of ionization technique since unknown thermally labile metabolites might be present in the plasma samples causing erroneous results. A high impact of ion suppression on the plasma concentrations after intravenous (i.v.) administration was found, depending on the drug formulation (vehicle). Since ion suppression caused significantly lower plasma concentrations (by a factor of up to 5.5) after i.v. dosing, the area under the curve (AUC) was underestimated and the plasma clearance was consequently erroneously high, with an impact on drug candidate selection. By simple stepwise dilution (e.g. 10-fold and 50-fold) of the supernatant of protein-precipitated plasma samples, including all calibration and quality control samples, the matrix effects were recognized and eliminated.


Assuntos
Plasma/química , Animais , Cromatografia Líquida de Alta Pressão , Etanol , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Injeções Intravenosas , Masculino , Espectrometria de Massas , Preparações Farmacêuticas/análise , Veículos Farmacêuticos , Polietilenoglicóis , Ratos , Ratos Wistar , Solventes , Espectrometria de Massas por Ionização por Electrospray , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...